![Swegon CASA Smart Blues Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/swegon/casa-smart-blues/casa-smart-blues_instructions-for-use-manual_1413672038.webp)
Important information
Separate extract air from
kitchen
The kitchen's general ventilation must
not be performed via the cooker hood
if the hood's duct is connected to the
ventilation unit's separate extract air
duct. The ventilation unit's separate
extract air duct runs past the heat
exchanger and the use of this duct will
have an effect on the annual efficiency
of the ventilation unit.
Qualified personnel only
The installation work, the enter-
ing of settings and commissioning
should be carried out by qualified
personnel only.
Standards and requirements
Applicable national standards and
regulations dealing with installa-
tion, the entering of settings and
commissioning must be followed
if the equipment is to operate
correctly.
At the www.swegonhomesolutions.
com address (Resources > Find PDF)
you will find “Project planning in-
structions for ventilation”, in which
power supply, sound, airflows
and duct system requirements are
presented.
The cooker hood must only be con-
nected to an outlet duct designed
for this purpose. In multi-storey
buildings, you must always have
permission from the company that
owns the property.
The cooker hood must only be con-
nected to an earthed electrical wall
outlet
Safety clearance
The distance between the cooker
hood's grease filter and the cooker
hob should be at least:
400 mm (recommendation 500 mm)
(electric cooker)
650 mm (gas hob)
Follow separate instructions from
the local authorities or the cooker
hood manufacturer, if they are
available.
Measurement and electrical
work
If you carry out voltage tests, meas-
ure the electrical insulation resist-
ance at various points or perform
other remedial measures that could
damage sensitive electronic equip-
ment, you must first isolate the
ventilation unit from the electrical
supply grid.
Surge protection
Swegon recommends that all venti-
lation units equipped with Smart
automatic control be equipped
with a surge protection device.
Earth fault circuit breaker
It is not certain that an earth fault
circuit breaker will operate fault-
lessly in combination with the
ventilation unit, since the unit's
regulation and control equipment
can cause leakage currents. Comply
with local electrical safety regula-
tions when you install electrical
equipment.
Service measures
The service measures that the user
himself can carry out are limited to
cleaning cooker hood surfaces and
the grease filter.
Never flame any food under the
cooker hood!
!