PIN Connection Application
Solder Side of
DSUB 25 PIN
Under the normal operation, COM disconnects with NO. But when any alarm is
triggered, COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.
EXTERNAL
ALARM COM
25
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial
communication signals.
RS485-B
24
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial
communication signals.
RXD232
23
When connecting the wire from ALARM INPUT (PIN 15 -- 22) to GND (PIN 1)
connector, DVR will start recording and the buzzer will be on.
When “MENU -> ADVANCE -> DETECTION -> DETECTION SETUP -> ALARM” is
set to “Low” : When the alarm input signal is “ Low ”, the unit starts to record and
buzzer.
When “MENU -> ADVANCE -> DETECTION -> DETECTION SETUP -> ALARM” is
set to “High” : When the alarm input signal is “ High ”, the unit starts to record and
buzzer.
ALARM INPUT
15~22
PIN OFF
14
Under the normal operation, COM disconnects with NO. But when any alarm is
triggered, COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.
EXTERNAL
ALARM NO.
13
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial
communication signals.
RS485-A
12
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial
communication signals.
TXD232
11
PIN OFF
10
When connecting the wire from ALARM INPUT (PIN 2 -- 9) to GND (PIN 1)
connector, DVR will start recording and the buzzer will be on.
When “MENU -> ADVANCE -> DETECTION -> DETECTION SETUP -> ALARM” is
set to “Low” : When the alarm input signal is “ Low ”, the unit starts to record and
buzzer.
When “MENU -> ADVANCE -> DETECTION -> DETECTION SETUP -> ALARM” is
set to “High” : When the alarm input signal is “ High ”, the unit starts to record and
buzzer.
ALARM INPUT
2~9
GROUND
GND
1
DESCRIPTION
FUNCTION
PIN
APPENDIX #2
APPENDIX #2
–
–
PIN CONFIGURATION
PIN CONFIGURATION
16CH / 8CH
16CH (D) / 8CH (D)
When the magnetic contact is opened, the
alarm will be triggered and the recording is
on. At the same time, COM connects with
NO and the siren with strobe starts wailing
and flashing.
NOTE:
Please go to MENU -> ADVANCE ->
DETECTION -> DETECTION SETUP, and
set ALARM to LOW on the local machine.