U
SER
’
S
M
ANUAL
H.264
R
EAL
T
IME
DVR
13
1-7.
RS-485 connection
①
This device has 1 data port (RS-485).
②
Use this port to connect the PTZ camera or the keypad.
(Optional)
③
PTZ camera / keyboard connection
i.
Connect the PTZ serial communication cable to the RS-485 port.
ii.
When connecting the cable, make sure that the TX- of the device is
connected to the RX- (TX-) of the camera (keyboard), and TX+ of the device is
connected to the RX+(TX+) of the PTZ camera(keyboard).
iii.
Recommended initial data setting is 9600 baud rate, 8 data bits, 1 stop bit
and no parity.
iv.
When connecting the PTZ camera or keyboard, always change the setting of
the DVR setting menu according the RS-485 setting of the camera, keyboard
and this device.
v.
Set the same baud rate when you are to use PTZ camera and keyboard at the
same time.
1-8.
Control port (output) connection
①
For interface and auto control with the external sensor, the interfacing control
output port (Set value from “Setup
Event
Sensor/Motion/Video loss” menu)
and the “RELAY” port are connected.
②
If the control device (Alarm light, amplified siren, external relay etc.) is “NC
(Normal Close)” type, connect to the control output NC (Normal Close) port.
③
If the control device (Alarm light, amplified siren, external relay etc.) is “NO
(Normal Open)” type, connect to the control output NO (Normal Open) port.
1-9.
Sensor (input) connection
①
Connect one of the signal cables (2 cables) of various sensors
(IR sensor, heat ray detector, magnetic etc.) to the COM port
and connect the remaining signal cable to the sensor number
you want. (Sensor “NC, NO” type can be set from “Setup
Event
Sensor” menu.)
4
Ground
5
Sensor 1
6
Sensor 2
7
Sensor 3
8
Sensor 4
Caution:
NC and NO cannot be selected simultaneously.