29 of 34
Indesit
Company
Service Manual UK
English
DISMANTLING INSTRUCTIONS - CONDENSER MODELS
SAFETY NOTES
1.
ENSURE THAT THE APPLIANCE IS UNPLUGGED BEFORE DISMANTLING.
2.
BEWARE OF SHARP EDGES ON METAL PANELS AND PRESSED PARTS.
A.
Top Cover
1.
Remove the 2 screws securing the top cover to the back panel.
2.
Slide the top cover back and lift clear of the retainers.
B.
Side Panels
1.
Remove the top cover.
2.
Remove the 3 screws securing the side panel to the rear panel.
3.
Pull the side panel backward to disengage from the lugs on the base panel.
NOTE:-
Different length screws are used to secure the side panels.
Take note of the screw length and positions when removing the side panels.
C.
Console Panel
1.
Remove the water container.
2.
Remove the top cover as in (A).
3.
Remove left side panel as in (B).
7.
Carefully remove the plastic securing rivet which retains the plastic water shield.
8.
Release the lower console securing lugs.
9. Noting the harness connections, disconnect the module.
10. Pull the console clear of the front Panel.
11. When reassembling, the Plastic Water Shield MUST be refitted and secured with the plastic rivet.
4.
Remove the 2 screws on the left hand side of
console securing the water container housing to
the console.
5.
Remove the 1 screw fixing the Water Container to
the front panel from the rear of the console (see
Fig. A).
6.
Remove the 2 round headed screws securing the
console to each side panel along its top edge.
Screw revealed
after removing
the side panel
Water Shield
Plastic Rivet