Swagelok TF16 Скачать руководство пользователя страница 4

4

     

Tube Facing Tool

 User’s Manual

Safety

Safety

Safety Information

 

  

Read the entire safety information section 
and Tube Facing Tool User’s Manual before 
using this product  Failure to do so can result 
in serious injury or death 

Signal Words and Safety Alert Symbols  

Used in this Manual

WARNING

   Statements that indicate a hazardous 

situation which, if not avoided, could result 
in death or serious injury.

CAUTION

   Statements that indicate a hazardous 

situation which, if not avoided, could result 
in minor or moderate injury.

NOTICE 

 

 Statements that indicate a hazardous 
situation which, if not avoided, could result 
in damage to the equipment or other 
property.

 

  Safety alert symbol indicating a potential 

personal injury hazard.

 

  Safety alert symbol indicating a potential for 

personal injury from electrical shock.

 

 

WARNING

 

Danger of death by electric shock

 

 

   If the power cord is damaged, electrically live 

parts may cause death if touched directly.

 

 

  Do not allow the tool to run unattended.

 

 

   The tool should be connected to a ground 

fault current interrupt (GFCI) protected outlet.

 

 

   Read through the operating instructions and 

safety information completely before using 
the rechargeable battery and charger of 
the TF16 series, TF24 series, or TF48 series 
cordless models.

 

 

   Work on electrical equipment must be done 

by a qualified electrician.

 

 

   Switch off the tool, allow it to run until it stops 

rotating and remove the plug from the power 
outlet or take out the rechargeable battery 
before changing tooling, maintaining, or 
transporting the tool.

 

WARNING

 

Danger of eyes being injured by hot and 
sharp-edged metal chips 

 

 

 Eye protection must be worn while operating or 
working near the equipment. 

 

 

WARNING

 

Keep dry  Equipment and components are 
not waterproof 

 

 

 Do not use electric tools and rechargeable 
batteries in a damp or wet environment. 

 

WARNING

 

Fire or Explosion

 

 

 Do not use in close proximity to flammable 
liquids or gases.

 

WARNING

 

Danger of being injured by rotating parts 

 

 

 Keep hands, loose clothing, and long hair away 
from rotating and moving parts.

 

  

WARNING

 

Danger of being injured by sharp cutting 
edges

 

 

   Do not touch the cutting insert while the tool 

is operating.

 

 

  Wear safety gloves.

 

 

   Do not remove chips or tubing from the work 

area when the tube facing tool is still running 
and the tool is not yet at rest.

 

 

   Wear safety gloves to remove chips. Remove 

long and bent chips with needle-nose pliers.

Содержание TF16

Страница 1: ...Tools This manual contains important information for the safe and effective operation of the Swagelok TF16 series TF24 series and TF48 series tube facing tools Users should read and understand its con...

Страница 2: ...2 Tube Facing Tool User s Manual...

Страница 3: ...Insert and the Tool Holder 12 Installing the Collet Set 13 Removing the Collet Set 13 Fitting the TF Cutting Bit MS TF BIT and the Tool Holder 14 Inserting and Replacing the Clamping Shells TF48 15 C...

Страница 4: ...ating instructions and safety information completely before using the rechargeable battery and charger of the TF16 series TF24 series or TF48 series cordless models Work on electrical equipment must b...

Страница 5: ...it run until it stops rotating when work is complete Environmental Protection Disposal Dispose of chips and used gear lubricant oil according to local regulations Electric tools and accessories conta...

Страница 6: ...ON OFF lock 2 Viewing window 6 ON OFF switch 3 Feed dial with scale divisions 7 Bench mount bracket optional 4 Motor 8 Tube clamp Fig 4 TF16 Series Cordless Model 1 Collet housing 5 Rechargeable batt...

Страница 7: ...switch 3 Viewing window 8 Bench mount bracket optional 4 Feed dial with scale divisions 9 Tube clamp 5 Motor Fig 6 TF24 Series Cordless Model 1 Collet lock 6 Rechargeable battery 2 Collet housing 7 ON...

Страница 8: ...amping screw 9 Base plate 4 Tensioning screw 10 Adjusting wheel for pre setting the speed 5 Protection 11 Driving motor 6 ON OFF switch 12 Cable with power plug Fig 8 TF48 Series Cordless Model 1 Tens...

Страница 9: ...l sizes of tubing and with different bevel angles are available Refer to the Application Range table on page 10 for size definitions Stainless Steel Collet Set These are used for deformation free clam...

Страница 10: ...onal materials Technical Data Series TF16 TF16 Cordless TF24 TF24 Cordless TF48 TF48 Cordless Dimensions in mm 15 4 W 7 87 H 2 76 D 390 W 200 H 70 D 10 3 W 10 0 H 3 15 D 261 W 255 H 80 D 15 8 W 13 8 H...

Страница 11: ...ation Restart protection to prevent the machine from starting in an uncontrolled way after it has been reconnected to the electrical power or after a power failure A quick change system for collet set...

Страница 12: ...onal x 0 118 to 0 236 3 0 to 6 0 0 118 to 0 236 3 0 to 6 0 Optional x 0 500 to 1 00 12 7 to 25 4 0 500 to 2 50 12 7 to 63 5 Optional x 0 118 0 835 3 0 to 21 2 0 250 0 835 6 35 to 21 2 Optional x 30 1...

Страница 13: ...et set 2 TF16 series Secure the collet set by turning the tube clamp clockwise until it stops TF24 series Secure the collet set by turning the collet lock s clockwise one turn Turn the tube clamp cloc...

Страница 14: ...otection is functional WARNING The MS TF BIT multifunctional tool may be damaged by wrong inserting of a tube Damage to tool Before clamping the tube ensure sufficient distance between the MS TF BIT a...

Страница 15: ...F BIT should be used Firmly clamp the tube to be machined into the clamping unit Immediately replace worn out tools The inner diameter of the clamping shells must be identical to the outer diameter of...

Страница 16: ...be damaged by incorrect set up Before clamping the tube verify there is space between the cutting insert and the tube 1 Insert the tube in the collet set of the tube facing tool 2 Secure the tube by...

Страница 17: ...Speed rpm 4 0 to 19 5 0 to 22 6 0 to 28 Adjusting the Speed Corded Models Set the speed by turning the speed dial TF16 TF24 TF48 Level Tube OD inch mm Level Tube OD inch mm Level Tube OD inch mm 3 0 1...

Страница 18: ...y the cable Only use original Swagelok tool parts Ensure free access to the power plug To be able to stop the machine also in case of emergency perform the corresponding steps and immediately remove f...

Страница 19: ...uide the tool further with the same amount of pressure WARNING The dial can be set to zero in accordance with the marking on the housing Each division mark corresponds to a feed motion of 0 002 in 0 0...

Страница 20: ...and bent chips with needle nose pliers or a similar tool NOTICE Excessive feed of the cutting insert into the tube can damage the cutting tool or cause the tool to overheat NOTICE Verify there is spac...

Страница 21: ...uce the speed according to Adjusting the Speed Facing the Tube Each division on the feed dial with scale adjustments equals an advancement of 0 004 in 0 1 mm It is recommended not to exceed a clamp th...

Страница 22: ...ote The ordering number for a replacement TF48 breakaway nut is MS TF48 NUT SQ 1 Verify the tool is unplugged or remove the battery 2 Loosen the M5 16 set screw using the provided 4 mm hex key 3 Remov...

Страница 23: ...tely remove the battery and then reinsert Breakaway nut has broken Replace the breakaway nut See Maintenance The motor is not running but the signal indicator lights up Quick flashing light The restar...

Страница 24: ...lok products are backed by The Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok Representative Swagelok Micro Fit TM Swagelok Company Metabo Metabow...

Отзывы: