SVS-VISTEK
Feature description
53
6.3.4
Assigning I/O Lines – IOMUX
The IOMUX is best described as a switch matrix. It connects inputs, and
outputs with the various functions of SVCam I/O. It also allows combining
inputs with Boolean arguments.
Figure 23: "IN0" connected to "debouncer"
The input and output lines for Strobe and Trigger impulses can be
arbitrarily assigned to actual
data lines
. Individual assignments can be
stored persistently to the EPROM. Default setting can be restored from
within the Camera.
Note:
If you connect the camera with a non-
SVS-Vistek GigEVision client, you
might not see the clearnames of the
lines, but only line numbers. In this
case, use this list of line names
LineSelector
translation
Line0
Output0
Line1
Output1
Line2
Output2
Line3
Output3
Line3
Output4
Line5
Uart In
Line6
Trigger
Line7
Sequencer
Line8
Debouncer
Line9
Prescaler
Line10
Input0
Line11
Input1
Line12
Input2
Line13
Input3
Line14
Input4
Line15
LogicA
Line16
LogicB
Line17
LensTXD
Line18
Pulse0
Line19
Pulse1
Line20
Pulse2
Line21
Pulse3
Line22
Uart2 In
Содержание HR Series
Страница 1: ...2 06 2019 Manual HR Camera Link hr25 hr29 hr43 hr120 ...
Страница 5: ...SVS VISTEK Safety Messages Contents of Camera Set 5 ...
Страница 14: ...SVS VISTEK Connectors 14 ...
Страница 62: ...SVS VISTEK Feature description 62 In a timings diagram the sequence values above will look like this ...
Страница 64: ...SVS VISTEK Feature description 64 will reflect as following ...
Страница 85: ...SVS VISTEK Dimensions 85 8 1 hr25 CL ...
Страница 86: ...SVS VISTEK Dimensions 86 ...
Страница 87: ...SVS VISTEK Dimensions 87 ...
Страница 88: ...SVS VISTEK Dimensions 88 8 2 hr29 CL ...
Страница 89: ...SVS VISTEK Dimensions 89 ...
Страница 90: ...SVS VISTEK Dimensions 90 ...
Страница 91: ...SVS VISTEK Dimensions 91 8 3 hr43 CL ...
Страница 92: ...SVS VISTEK Dimensions 92 ...
Страница 93: ...SVS VISTEK Dimensions 93 ...
Страница 95: ...SVS VISTEK Dimensions 95 ...
Страница 96: ...SVS VISTEK Dimensions 96 ...