SVS-VISTEK
Feature description
40
Figure 10: overview of FVAL and LVAL signal timing on Camera Link
Figure 11: more detailed view of LVAL signal timing on Camera Link
Example calculation
on exo174*CL
>
t
Lvd
=
(1920 / 2)
px in line / sent at once
×
(1/85MHz)
CL_clock
=
960
×
(1/85e
6
) s
≈
11,29 µs
>
t
nvd
=
3 × (1/85MHz)
time between two valid line data packages
=
(3/85e
6
) s
≈
35,3 ns
>
t
Fvd
=
2 x (1/85MHz)
delay before first line
+
( t
LVd
+
t
nvd
)
×
1200
lines [count]
=
(2/85e
6
) s
+
( 11,29 µs
+
35,3 ns )
×
1200
=
23,5 ns
+
( 11,29 µs
+
35,3 ns )
×
1200
=
( 2 + (960 + 3) × 1200 ) s
/
85e
6
≈
13,6 ms
Camera Link architecture exo174*CL: 1X2_1Y count = 2
pixelh =1920 pixelv = 1200 CL_clock = 85 MHz
Figure 12: example calculation of Camera Link timing on a exo174*CL
Содержание HR Series
Страница 1: ...2 06 2019 Manual HR Camera Link hr25 hr29 hr43 hr120 ...
Страница 5: ...SVS VISTEK Safety Messages Contents of Camera Set 5 ...
Страница 14: ...SVS VISTEK Connectors 14 ...
Страница 62: ...SVS VISTEK Feature description 62 In a timings diagram the sequence values above will look like this ...
Страница 64: ...SVS VISTEK Feature description 64 will reflect as following ...
Страница 85: ...SVS VISTEK Dimensions 85 8 1 hr25 CL ...
Страница 86: ...SVS VISTEK Dimensions 86 ...
Страница 87: ...SVS VISTEK Dimensions 87 ...
Страница 88: ...SVS VISTEK Dimensions 88 8 2 hr29 CL ...
Страница 89: ...SVS VISTEK Dimensions 89 ...
Страница 90: ...SVS VISTEK Dimensions 90 ...
Страница 91: ...SVS VISTEK Dimensions 91 8 3 hr43 CL ...
Страница 92: ...SVS VISTEK Dimensions 92 ...
Страница 93: ...SVS VISTEK Dimensions 93 ...
Страница 95: ...SVS VISTEK Dimensions 95 ...
Страница 96: ...SVS VISTEK Dimensions 96 ...