SVS-VISTEK
Feature-Set
83
In the SVCam’s these signals are used to send low-power data signals to
control light or lenses (MFT).
Table 2: serial interface parameter – RS-232 and RS-422
RS-232
It is splitted into 2 lines receiving and transferring Data.
RXD
receive data
TXD
transmit data
Signal voltage values are:
low:
-3 … -15 V
high: +3 … +15 V
With restrictions: refer to Table: serial interface parameter above.
Data transportis asynchronous. Synchronization is implemented by fist and
last bit of a package. Therefore the last bit can be longer, e.g. 1.5 or 2
times the bit duration). Datarate (bits per second) must be defined before
transmission.
Serial interface Parameter
RS-232
RS-422
Maximum open-circuit voltage
±25 V
±6 V
Max Differential Voltage
25 V
10 V
Min. Signal Range
±3 V
2 V
Max. Signal Range
±15V
10 V
Содержание eco4050
Страница 1: ...2 26 2018 Manual EVO series evo1050 evo2050 evo2150 eco4050 evo4070 evo8051 ...
Страница 14: ...SVS VISTEK Getting Started 14 Installation will proceed 8 Installation completed ...
Страница 16: ...SVS VISTEK Getting Started 16 Conform to GenICam all control features will be listed in a flat tree diagram ...
Страница 21: ...SVS VISTEK Getting Started 21 4 5 Driver Circuit Schematics Figure 5 basic Illustration of driver circuit ...
Страница 23: ...SVS VISTEK Connectors 23 ...
Страница 29: ...SVS VISTEK Dimensions 29 ...
Страница 32: ...SVS VISTEK Dimensions 32 ...
Страница 33: ...SVS VISTEK Dimensions 33 ...
Страница 57: ...SVS VISTEK Feature Set 57 ...
Страница 66: ...SVS VISTEK Feature Set 66 Figure 43 I O Lines with open end indicate physical in and outputs ...
Страница 76: ...SVS VISTEK Feature Set 76 Strobe Control Example Setup Figure 50 Illustration of an application using the 4IO ...
Страница 129: ...SVS VISTEK Troubleshooting 129 Space for further descriptions screenshots and log files ...
Страница 131: ...SVS VISTEK IP protection classes 131 ...