SVS-VISTEK
Feature-Set
58
7.2.5
LookUp Table
The LookUp Table Feature (LUT) lets the user define certain values to
every bit value that comes from the ADC.
To visualize a LUT a curve diagram can be used, similar to the diagrams
used in photo editing software.
The shown custom curve indicates a contrast increase by applying an S-
shaped curve. The maximum resolution is shifted to the mid-range.
Contrasts in this illumination range is increased while black values will be
interpreted more black and more of the bright pixels will be displayed as
100 % white...
For further Information about curves and their impact on the image refer
to our homepage:
Figure 36: Custom LUT adding contrast to the midtones
NOTICE
LUT implementation reduces bit depth from 12 bit to 8 bit
on the output.
Содержание eco4050
Страница 1: ...2 26 2018 Manual EVO series evo1050 evo2050 evo2150 eco4050 evo4070 evo8051 ...
Страница 14: ...SVS VISTEK Getting Started 14 Installation will proceed 8 Installation completed ...
Страница 16: ...SVS VISTEK Getting Started 16 Conform to GenICam all control features will be listed in a flat tree diagram ...
Страница 21: ...SVS VISTEK Getting Started 21 4 5 Driver Circuit Schematics Figure 5 basic Illustration of driver circuit ...
Страница 23: ...SVS VISTEK Connectors 23 ...
Страница 29: ...SVS VISTEK Dimensions 29 ...
Страница 32: ...SVS VISTEK Dimensions 32 ...
Страница 33: ...SVS VISTEK Dimensions 33 ...
Страница 57: ...SVS VISTEK Feature Set 57 ...
Страница 66: ...SVS VISTEK Feature Set 66 Figure 43 I O Lines with open end indicate physical in and outputs ...
Страница 76: ...SVS VISTEK Feature Set 76 Strobe Control Example Setup Figure 50 Illustration of an application using the 4IO ...
Страница 129: ...SVS VISTEK Troubleshooting 129 Space for further descriptions screenshots and log files ...
Страница 131: ...SVS VISTEK IP protection classes 131 ...