YH4
GRAND
VITARA
1. Air flow
AIR CONDITIONING (OPTIONAL)
1B-35
CONDENSER COOLING FAN ASSEMBLY
INSPECTION
Remove condenser assembly (Refer to “A / C CONDENSER AS-
SEMBLY REMOVAL” in this section).
Check continuity between terminal to terminal as shown.
If check results are continuity, proceed to next operation check.
If not, replace.
Connect battery to condenser fan motor as shown, then check
that the condenser fan motor operates smoothly and specified
current.
Specified current: Maximum 12 A at 12 V