Starting System: 1I-4
Starter System Troubleshooting
ZAJ6111904001
CAUTION
If any abnormality is found, immediately disconnect the battery cables from the battery.
NOTE
Before troubleshooting the electric starter system, make sure of the following:
• Battery is fully charged.
• All cables / wires are securely connected.
• Shift is in “Neutral” position.
• Emergency stop switch lock plate is set in place.
• Fuse is not blown.
Circuit Check Schematic
12
ECM
35
36
15
49
2
65
16
1
2
6
5
4
7
9
10
11
3
8
12
13
14
“A”
IAJ611190006-01
1. Battery
5. Main relay
9. Ign. switch “START”
13. START s/w signal
2. Main fuse
6. Starter relay
10. Emergency switch
14. Magnetic switch
3. Fuse (ECM)
7. Neutral switch
11. Neutral switch signal
4. Fuse (Starter)
8. IG. s/w ON
12. Starter relay control signal