38
Logging data with multiple data recorders
Setup two Sutron data recorders with one SDI-12 AnalogPlus module
This setup allows for a SDI-12 AnalogPlus module sensor to be logged in two Sutron data recorders at the
same time.
Connect the SDI-12 ground line to both data recorders and the SDI-12 AnalogPlus module
Connect the SDI-12 Data line to both data recorders and the SDI-12 AnalogPlus module
Connect the SDI-12 power line from one Data recorder to the SDI-12 AnalogPlus module
NOTE: Measurement time in one of the data loggers should be offset by at least 30 seconds with respect to
the other data logger.
Setup two Sutron Data Recorders with two SDI-12 AnalogPlus modules
This setup allows for two SDI-12 AnalogPlus module sensors to be logged in two Sutron Data recorders at
the same time.
Connect the SDI-12 ground line to both data recorders and both SDI-12 AnalogPlus modules
Connect the SDI-12 Data line to both data recorders and both SDI-12 AnalogPlus modules
Connect the SDI-12 power line from one Data recorder to one SDI-12 AnalogPlus module
Connect the SDI-12 power line from the other Data recorder to the other SDI-12 AnalogPlus module
Sensors must have different addresses.
Measurement time in one of the data loggers should be offset by 30 seconds with respect to the other
datalogger.