P/N: 670-00029A
2/17/12
27
7.11 Hydraulic Tubing and Cable Management
•
Coil up excess hydraulic flexible tubing into approximately 6 in. (150mm)
diameter coil(s) and attach to the workstation using the mounting clips and/or
cable ties. Take special care not to damage flexible tubing during this operation.
•
While it is recommended to coil up excess tubing when hydraulic tubing lengths
are too long, the lines can be shortened. Contact Suspa
®
Incorporated for detailed
Movotec
®
Tube Shortening Instructions.
•
If hydraulic tubing lengths are too short, it is only possible to make the tubing
lengths longer by replacing the line, using a Movotec
®
Refill Kit. Contact Suspa
®
Incorporated for a more information and instructions.
•
Check flexible tubing to ensure it is secured to the workstation and that no
damage has been sustained during this operation.