Attention, hot surface

HANDLING PRECAUTIONS

When  handling  the  NANOPAK  Totem,  please  take  the  required  precautions  and  pay 

particular attention to the following diagrams:

Attention, risk of electric shock

Alternating current

The protective earth is a safety measure which makes it possible, in the case of error, to 

deliver a dangerous electrical current to the ground.

The protective earth, « PE »  measure » is guaranteed by the protective conductor.

The protective earth, « PE » (with green/yellow insulating sheath) is a conductor used as a 

measure of protection during an indirect contact to connect metallic elements with:

- other objects;

- foreign conducting elements;

- ground terminals, ground conductors, and active elements which have been earthed.

Warning about a risk due to hot surfaces during the handling, for example, of 

machines, tools, etc…

The symbol indicates a dangerous situation which, if the correct behavior is not 

adopted, can lead to slight bodily harm and possible material damage.

In order to cause burns to a human being, a hot surface must have a temperature of above 

45°C. Warning signs should be present for temperatures above 60°C.

Behavior to adopt:

Such workplaces pose a risk of burning or scalding and those involved with such equipment 

must take appropriate care.

Warning of dangerous voltage in the workplace.

Behavior to adopt:

In workplaces associated with a risk of dangerous voltage, personnel must be 

qualified (for example, hold electrician qualifications and have a  knowledge of electronic 

engineering) and have the express authorization of the company head.

Non-authorized  persons  should  not  have  access  to  these  workplaces  or  open  the  such-

indicated electrical boxes or cabinets.

Application:

This symbol denotes electrical installations or devices supplied with alternating 

current.

Behavior to adopt:

The installations and devices must be provided with an alternating current supply.

Protective earth

Application:

On  electrical  installations  and  devices  belonging  to  the  electrical 

protection class:

“Protective earth”

9

Содержание Micropak 3

Страница 1: ...LPRCameraInstallation SettingsManual...

Страница 2: ...part from the settings adjustment and configuration the most important factor for optimal functioning is the camera installation location This manual presents the general principles of camera installa...

Страница 3: ...of MICROPAK 2 2 1 Characteristics of the MICROPAK 2 2 2 Attachment of the support bracket to the wall using the fixation kit with angular displacement provided by SURVISION 2 2 3 Fixation of support...

Страница 4: ...1 Installation location 4...

Страница 5: ...the plate to be read Angle restrictions The total sum of the vertical angle and the horizontal angle the angle formed between the roadside and the camera aiming line should not exceed 30 The camera mu...

Страница 6: ...camera view of the vehicle should not be totally or partially concealed by any environmental element barrier bar or column advertising sign etc There should be no vehicle or pedestrian passing betwee...

Страница 7: ...the rear The minimum distance of 7m 22 97 ft ensures that the plate is read before the vehicle arrives at the terminal even for the longest vehicles The camera must be installed at a horizontal distan...

Страница 8: ...8 2 Assembly...

Страница 9: ...ted can lead to slight bodily harm and possible material damage In order to cause burns to a human being a hot surface must have a temperature of above 45 C Warning signs should be present for tempera...

Страница 10: ...ellow cables can be connected to the dry contact of the barrier if necessary 1 Remove rear part The NANOPAK is already installed in the Totem on delivery 3 If you assemble the Totem directly on site t...

Страница 11: ...t of the terminal The Ethernet cable to be used which is not provided by SURVISION must be at least Cat5e in accordance with local regulations The circuit breaker should be selected according to the s...

Страница 12: ...Step 3 3 1 Install the backplane in the totem Fix the screws of the backplane as well as the NANOPAK by adjusting the inclination Step 4 12 SURVISION can carry out this operation See 2 1 3 3 2 Connec...

Страница 13: ...wing the diagram L N attached to the interior of the totem ie L Live N Neutral Ground The power supply of the Totem must respect the following criteria 100 VAC 240 VAC in 50 60Hz on entry 24 VDC on ex...

Страница 14: ...s in the USA only include the power cables The power cable measures 3m Power supply 24 VDC Consumption 12 W The options available with the MICROPAK are White lighting Pole mounting support Support fix...

Страница 15: ...p 2 1 2 First attach the three screws but not the one on the curved ruler 1 3 Then fit the screw on the curved ruler to set the required tilt 20 in our example Fit the cradle and the camera to the bra...

Страница 16: ...pport bracket to the ceiling using the fixation kit with angular displacement provided by SURVISION Step 1 1 1 Fit the cradle to the front of the sunvisor on the lower part using the diameter M5 screw...

Страница 17: ...adle and the camera to the bracket using the two screws of diameter M6 Step 2 Step 3 Adjust the plane of the camera so that the plates appear horizontal in the image using the central screw under the...

Страница 18: ...onds to a strong twisting by hand but without tools 2 2 5 Diagram of MICROPAK power supply connector This cable provide SURVISION The MICROPAK power supply connecter allows us to connect the camera to...

Страница 19: ...age 40W The options available with the VISIPAK are Colour optical head White lighting Speed calculation Extended temperature 40 to 131 F on start up 24V power supply Pole mounting system Articulated a...

Страница 20: ...the rubber plate The VISIPAK can be mounted from underneath as illustrated below or by above by using the holes of the visor screws to attach the bracket Fit the bracket into place fit and tighten the...

Страница 21: ...ed angle bracket allows for prior installation adjustment in workshop Fit the bracket into place fit and tighten the supplied screws Prior adjustment helps save time during installation and limit the...

Страница 22: ...22 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 2 3 4 Assembly of AMPHENOL connector for VISIPAK...

Страница 23: ...2 3 5 Assembly of the visor 23 Step1 Screw the small struts to the top Install the visor and tighten with the four screws provided Step 2...

Страница 24: ...24 3 Aiming Setting adjustment...

Страница 25: ...of SURVISION cameras 1 2 4 3 5 To carry out this procedure the latest version of the VSS must be installed This program is available on my survision fr Adjust the aim in such a way that the plate is i...

Страница 26: ...tion in a CDKMSG file menu settings Save Conguration to File and store it carefully to be able to recharge it if necessary for maintenance purposes Unlock the camera and wait for the VSS welcome scree...

Страница 27: ...4 Maintenance 27...

Страница 28: ...gne that the glass is getting dirty An appropriate frequency of cleaning can be defined during the first year of use of deployment As a precaution on the occasion of periodical cleaning the maintenanc...

Страница 29: ...g a RJ45 cable Use the VSS software tool to check that the camera is present on the network 4 Try to connect to the camera check that there is an image and that the plates of passing vehicles are read...

Страница 30: ...laration is not carried out The cameras must be packaged in an appropriate way for fragile optoelectronic equipment On request SURVISION can supply packages specifically designed to guarantee protecti...

Страница 31: ...ISION 11251 NW 20th St 116 Miami FL 33172 USA Tel 1 786 362 5471 contact survisiongroup com SURVISION 22 rue d Arras 92000 NANTERRE FRANCE Tel 33 1 47 51 04 80 contact survision fr www survisiongroup...

Отзывы: