![Survision Micropak 3 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/survision/micropak-3/micropak-3_installation-and-settings-manual_1407694007.webp)
7
1.4 - Specific rules for ceiling installation when reading from the front
Installation location rules to ensure maximum performance:
1.5 - Specific rules for installations in car-parks and normal toll installations
when reading from the rear
The minimum distance of 7m/22.97 ft ensures that the plate is read before the vehicle arrives
at the terminal, even for the longest vehicles.
The camera must be installed at a horizontal distance “X”, equal to half of H, the
installation height less the height of the barrier bar.
The space given by the distance x ensures that the plate is read before the plate arrives at
the barrier, without the barrier appearing in the image.
Содержание Micropak 3
Страница 1: ...LPRCameraInstallation SettingsManual...
Страница 4: ...1 Installation location 4...
Страница 8: ...8 2 Assembly...
Страница 22: ...22 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 2 3 4 Assembly of AMPHENOL connector for VISIPAK...
Страница 24: ...24 3 Aiming Setting adjustment...
Страница 27: ...4 Maintenance 27...