SurgeX SX-1115ip-X Скачать руководство пользователя страница 4

iControl Manual                                                                                           

 

 

 

INTRODUCTION 

 
The SurgeX

®

 iControl SX-1115ip-X (SX-1120ip-X) is a single rack-space, 120V, 15 (20) amp, 

AC power conditioner that can be controlled over a network or the internet. The iControl 
incorporates SurgeX

 

Advanced Series Mode

®

 power conditioning and surge elimination, as well 

as SurgeX Impedance Tolerant

®

 EMI/RFI filtering. The simple web server structure allows basic 

control of the outlets (and groups of outlets) and viewing of status information all from the home 
page. The extensive programming and setup capabilities are accessed by a Setup and Control 
Utility (SCU) or through a Command Line Interface (CLI).   
 
Telnet and serial access use the same Command Line Interface (CLI) structure and syntax to 
completely configure the iControl, or multiple iControls in a cluster configuration. 
 
Up to 16 iControls can be linked together and controlled from a single web or CLI interface. One 
master iControl provides the communication to the users and continuously receives status 
information from the rest of the iControls in the cluster. Up to 128 outlets can be controlled in 
this manner from one IP address. 
 
Multiple outlets, across multiple iControls in clustered configurations, can be linked together in 
named groups and managed together. This allows, for example, power cycling all devices of a 
certain type together. 
 
Up to 16 systems can be continuously monitored with AutoPing, with automatic power control 
upon loss of contact. Reboot crashed systems, or provide auto power-up or –down for 
environmental controls and notification systems. 
 
Up to 16 users can be assigned administrator or user only rights, plus access to specific outlets 
and groups. Users only see the outlets and groups they are assigned to. 
 
The eight rear-mounted receptacles can each be individually controlled.  
The metering includes the AC line voltage and total current draw. 
 
 
 
 
 
 
 
 
 
 
 
Located on the rear panel are the input power cord, circuit breaker (15A or 20A), 8 NEMA 5-15 
AC outlets, Serial connection (DCE, 9 pin D-subminiature), Network connection (RJ-45), Phone 
connection (RJ-11), and Expansion Ports for cluster configurations. 
 

Содержание SX-1115ip-X

Страница 1: ...0 USER MANUAL SurgeX SX 1115ip X SX 1120ip X Web Enabled Power Conditioning Management System Software Version vQ110630G 123 Firmware Version Q110630G 285...

Страница 2: ...NE 9 EXPANSION 9 LED INDICATORS 10 WEB SERVER 10 HEADER 10 CONTROL 11 STATUS 11 DEVICE VIEW 11 OUTLET STATUS 12 GROUP VIEW 12 GLOBAL VIEW 12 AUTOPING VIEW 13 COMMAND LINE INTERFACE CLI PROTOCOL 14 OUT...

Страница 3: ...TROL 23 TIMED EVENTS 24 AUTOPING 25 SSL SECURITY 26 CERTIFICATE UPLOAD UTILITY 27 EMAIL NOTIFICATION 28 SNMP 29 FIRMWARE UPGRADES 29 FRONT PANEL RESET BUTTON 29 SETUP AND CONTROL UTILITY SCU 30 SNMP M...

Страница 4: ...e users and continuously receives status information from the rest of the iControls in the cluster Up to 128 outlets can be controlled in this manner from one IP address Multiple outlets across multip...

Страница 5: ...work The internal modem for models with internal modem option supports data calls from terminal devices using the CLI and direct dial from a tone telephone for simple On Off control when more sophisti...

Страница 6: ...ter use or as backup 5 Open saved configurations for change management 6 Clone saved configurations for replication of similar configurations in multiple iControls 7 Upload modified configurations to...

Страница 7: ...the current IP Address of the iControl Factory Default is 192 168 0 254 telnet Port 23 Connect to the Serial port or via PSTN connection to the modem Factory Default is 115200 8 n 1 Upon connection pr...

Страница 8: ...teway 192 168 1 7 Reboot Required OK iControl reboot IP Address 192 168 1 3 Once the IP address is set the following command can be used to prevent DHCP or ARP Ping from altering it set ipmode static...

Страница 9: ...Address MAC Address Where IP Address is the desired IP address in dotted decimal for the iControl and the MAC address is the MAC Address of the iControl The MAC Address of the iControl is located on...

Страница 10: ...ort Connection The iControl has a 9 pin D subminiature connector for RS 232 serial control The connector is configured as DCE for direct connection to a laptop or other terminal device Default serial...

Страница 11: ...ks In cluster configurations all 128 outlets can be managed from the web pages The interface is divided into three sections Header Control and Status Each user will only be able to view and control th...

Страница 12: ...s can be used to prevent over current draw on initial power up of devices Entries of 0 to 99 seconds are valid The Select All and Select None buttons allow selection or de selection of all outlets Ref...

Страница 13: ...oups are two or more outlets linked together for simultaneous control In the group view each device containing a member of the group is displayed on a line with the status of the outlets that are grou...

Страница 14: ...column will display the current status of the AutoPing The numeric column will display the number of times the AutoPing has been triggered A numeric counter other than 0 with the status reporting OK i...

Страница 15: ...selected outlet to the selected state The user must have rights to the selected outlet This command is for iControls not used in a cluster configuration If used in a cluster it is the same as device 1...

Страница 16: ...ser in the root iControl s user table 20 character max Yes set user username device 1 16 devname all outlet 1 8 all yes no Sets the user s right to the selected outlet on a specific device Yes No Righ...

Страница 17: ...y used since the last counter reset The energy counter can be reset via SCU or web page and will also reset after a reboot get current Get the measured current of the local iControl Yes get device 1 1...

Страница 18: ...onsole configuration Timeout and Baud Rate Yes set console timeout 30 3600 disable Console can be set to automatically logout with no activity for 30 seconds to 1 hr in seconds or disabled Yes 120 set...

Страница 19: ...tlets of standalone or Master of cluster configuration device ID 0 or 1 May cause outlet changes in expansion units device ID 2 16 Yes Group Commands Command Description Admin Fact Def get groups Retu...

Страница 20: ...b enable yes no Enable or disable the root iControl s web server Yes Yes set web port 1 65535 Set the root iControl s web server s port Web standard port is 80 If changed access the iControl using htt...

Страница 21: ...ing requires before it triggers its action Yes 3 set autoping 1 16 device name 1 16 outlet 1 8 Assign an autoping to either a device outlet or group Each autoping can be assigned to one or the other Y...

Страница 22: ...a device outlet or group Each event can be assigned to one or the other Yes set event eventname control group groupname Yes Email Commands Command Description Admin Fact Def set email enable yes no T...

Страница 23: ...of the root iControl s RTC Only valid if NTS is disabled Yes set time minute 0 59 Sets the minute of the root iControl s RTC Only valid if NTS is disabled Yes set time day 1 31 Sets the day of the ro...

Страница 24: ...the outlet for the time configured with the CLI command cycle time The new status of the outlet is stated If the key is used the iControl will also state begin to indicate the reboot or cycle has beg...

Страница 25: ...ssign the event to a specific outlet or group and then configure the initial occurrence of the event the action to be performed and the repeat frequency if desired To configure the timed events use th...

Страница 26: ...he ping response returns the iControl will power off the outlet Off Latch Upon triggering the iControl will power off the assigned outlet and remain so until changed via the web or telnet serial inter...

Страница 27: ...ntrol To configure the AutoPing use the following commands set autoping 1 16 ipaddress dotted decimal set autoping 1 16 action action set autoping 1 16 frequency 1 999 set autoping 1 16 count 1 99 set...

Страница 28: ...Control the user will be offered an opportunity to install the certificate from the iControl This is done once for each browser on the PC and each iControl Self Sign Method Step 1 Using the CU create...

Страница 29: ...can be turned on or off for that user set user name email email address 64 char max set user name sendmail yes no Emails generated by the iControl will display the device outlet s command and the use...

Страница 30: ...to 128 Char 7 RO INTEGER sysServices FIRMWARE UPGRADES The iControl can be upgraded via the network if the upload feature has been enabled using the set upload enable yes command on the console interf...

Страница 31: ...d configurations for change management 6 Clone saved configurations for replication of similar configurations in multiple iControls 7 Upload modified configurations to iControls 8 Control outlets on o...

Страница 32: ...nable 12 RW Integer32 cycleTime 13 RW Integer32 delayTime 2 TB snmpManagerTable 1 TE snmpManagerEntry 1 RO Integer32 snmpManagerIndex 2 RW DisplayString snmpManagerIPAddress 3 RW INTEGER Enum snmpMana...

Страница 33: ...and 2 this device must accept any interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could voi...

Страница 34: ...nergy Unlimited due to current limiting Endurance C62 41 1991 category B3 pulses 1 KV 500 000 3 KV 10 000 6 KV 1000 Undervoltage Shutdown Adjustable from 90 Volts to 105 Volts Overvoltage Shutdown Adj...