• Some components may be heavy and/or bulky. Always use proper lifting and carrying
techniques when handling components, especially when working on a ladder, roof, or other area
with a fall hazard.
• The exterior antenna must not be co-located or operating in conjunction with any other antenna.
• Always use a properly installed SureCall lightning protector between the exterior antenna and
the booster.
•
Always power off the booster before working on the roof of the building or anywhere in close
proximity to the external antenna.
• Allow at least 24 inches (60 cm) of separation between interior antennas and humans or
animals.
• Allow at least 24 inches (60 cm) of separation between exterior antennas and all persons.
• Comply with all antenna separation requirements to prevent signal oscillation.
CAUTION: SIGNAL OSCILLATION CAN CAUSE
RADIO INTERFERENCE WITH CELLULAR TOWERS
AND RESULT IN CIVIL AND/OR CRIMINAL
PENALTIES.
CAUTION: FAILURE TO PROPERLY INSTALL A
LIGHTNING PROTECTOR CAN RESULT IN DAM
-
AGE TO THE BOOSTER, ANTENNAS, AND WIRING.