Sure Heat Manufacturing AEVF18FALP Скачать руководство пользователя страница 7

7

INSTALLATION

 

WARNING: A quali

ed service person must 

install appliance. Follow all local codes.

 WARNING: Never install in a bedroom 

or bathroom. Any heating product with a 

Btu/Hr rating over 10,000 cannot be used 

in a bedroom. Any heating product with a 

Btu/Hr rating over 6,000 cannot be used 

in a bathroom.

 WARNING: Before installing in a solid-

fuel-burning 

fireplac

e,  the  chimney 

flue 

and 

fireb

ox must be cleaned of soot, creo-

sote, ashes, and loose paint by a 

qualified 

chimney cleaner. 

 WARNING: Never install the appliance

•  in a recreational vehicle

•  where curtains, furniture, clothing, or

   other 

flamma

ble objects are less than 

   36 inches (91.5 cm) from the front, top,  

   or sides of the appliance

•  in a wood-burning stove

•  in high-traffic areas

•  in windy/drafty areas

NOTICE: This  appliance  is  intended  for 

supplemental  heating.  Use  this  heater 

along with your primary heating system. 

Do not install this heater as your primary 

heat source. If you have a central heating 

system, you may run system’s circulating 

blower while using heater. This will help 

circulate the heat throughout the house. In 

the event of a power outage, you can use 

this heater as your primary heat source.

CAUTION: This appliance creates warm 

air currents. These currents move heat to 

wall surfaces next to appliance. Installing 

appliance next to vinyl or cloth wall cover-

ings or operating appliance where impurities 

(such as tobacco smoke, aromatic candles, 

cleaning 

fluids

, oil or kerosene lamps, etc.) 

in the air exist, may discolor walls.

IMPORTANT:

 Vent-free heaters add moisture to the air. 

Although this is 

beneficial,

  installing 

appliance

 in rooms 

without enough ventilation air may 

cause

 mildew to form 

from  too 

much

  moisture.  See  Air  for  Combustion  and 

V

entilation,

 page 4. 

CHECK GAS TYPE

Use the 

correct

 gas type (natural or propane/LP) for your 

appliance.

 If your gas supply is not 

correct

 or if you do not 

know your gas 

type,

 do not install 

appliance.

INSTALLATION ITEMS NEEDED

Before installing 

appliance,

 make sure you have the items 

listed below.

•  external regulator for propane/LP unit only (supplied by 

    installer)

• 

piping (check local codes)

•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
• 

test guage connection *

•  ground joint union (if required)

•  sediment trap (suggested)
•  tee joint

• 

pipe wrench

•  approve

d flexible gas line connector (if allowed by local

    codes) (not provided)

*  A CSA/AGA design-

c

erti

ed equipment shutoff valve 

with 1/8" NPT tap is an 

acc

eptable alternative to test gauge 

c

onne

c

tion. Pur

c

hase the optional CSA/AGA design-

c

erti

ed 

equipment shutoff valve from your dealer.
For propane/LP 

units,

 the installer must supply an external 

regulator. The external regulator will 

reduce

 

incoming

 gas 

pressure. You must redu

c

e in

c

oming gas pressure to between 

11 and 14 

inches

 of water. If you do not 

reduce

 

incoming 

gas pressure, heater regulator damage could occur. 

LOG SET PLACEMENT

Place the log set burner system in the center of your fire-

place or fire box. Ensure enough space around the logs

for air circulation.If the fireplace (or firebox) is too small 

for the logs, do not install. 

Содержание AEVF18FALP

Страница 1: ...l with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local cod...

Страница 2: ...e explosion electrical shock and carbon monoxide poisoning WARNING Any change to this heater or its controls can be dangerous WARNING Do not allow fans to blow directlyintotheappliance Avoidanydrafts...

Страница 3: ...ty shutoff system The ODS shuts down the replace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages...

Страница 4: ...t can be used to turn the log set on and off The thermostat setting can also be selected Thermostat setting senses the room temperture at the location of the remote handset The thermostat will automat...

Страница 5: ...ing uncon ned space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the oor on the wall connecting the two spaces see Figure 1 You can also remove door into a...

Страница 6: ...nts to the outdoors Example Vent free log set ______________ Btu Hr Gas water heater _____________ Btu Hr Total ________ Btu Hr 4 Compare the maximum Btu Hr the space can support with the actual amoun...

Страница 7: ...oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is bene cial installing appliance in rooms without enough ventilation ai...

Страница 8: ...could occur For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If...

Страница 9: ...end that you install a sediment trap in supply line as shown in Figure 6 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate se...

Страница 10: ...ane LP Apply noncorrosive leak detection uid to all joints Bubbles forming show a leak 4 Correct all leaks at once BATTERY INSATLLATION Batteries must be installed in the appliance for it to funct ion...

Страница 11: ...Log Placement American Elm 18 Models 11...

Страница 12: ...Log Placement American Elm 24 Models 12...

Страница 13: ...clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step Note Before applying any power supply...

Страница 14: ...n switch opened Note You may be running this heater for the first time after hooking up to gas supply If so the control switch may need to be pressed in more than one time This will allow air to bleed...

Страница 15: ...Gas To Log Set page 14 see Troubleshooting pages 17 through 20 If burner flame pattern is incorrect as shown in Figure 23 you should turn heater off see To Turn Off Gas To Appliance page 14 Refer to...

Страница 16: ...s on the can you could damage the pilot assembly Figure 23 Injector Holder On Outlet Burner Tube 1 Shut off the unit including the pilot Allow the unit to cool for at least 30 minutes 2 Inspect burner...

Страница 17: ...pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Call for service 5 Replace pilot assembly 6 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve...

Страница 18: ...ocal natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 16 7 Replace pilot assembly Replace control valve 1 Clean burner ori ce see Cleaning and Maintenance page 16...

Страница 19: ...lean ers or similar products 1 This is normal with most log sets If noise is exces sive contact a quali ed service person 1 Refer to Air For Combus tion and Ventilation require ments page 4 1 Disconti...

Страница 20: ...chemicals new carpet etc see IMPOR TANTstatement above 2 Low fuel supply propane LP gas only 3 Gas leak See Warning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3...

Страница 21: ...operate the gas valve to the OFF position How to Clear Cycle ON OFF switch to OFF position Two beeps per second Automatic Recycle Description of Fault Pilot is proven and lost 3 times within 2 minute...

Страница 22: ...1 2 3 4 5 6 7 8 9 10 11 11 L 12 13 14 15 16 17 18 22 ILLUSTRATED PARTS BREAKDOWN S B VFA FULLY AUTO MODELS...

Страница 23: ...RMH 120 584912 RMH 120 584912 1 Nut ODS Mounting RMH 120 00051 RMH 120 00051 RMH 120 00051 RMH 120 00051 2 Screw Hex 8 X 3 8 RMH 122 00625 49738375 49738375 49738375 6 Decorative Rock WIP 130 00050 W...

Страница 24: ...discoloring of any kind use or installation contrary to specified instructions and applicable building codes including heating the product to temperatures above its rated speci cations which can caus...

Отзывы: