14
3. Turn the main manual gas valve clockwise
to the full OFF position.
Initializing the System for the First Time
Pilot
IPI/CPI
System
ON/OFF
Command
Burner
System
Switch
Switch
Name
State
Opened, IPI
Turn-OFF
Flames OFF
Opened, IPI
Closed
Turn-ON
Pilot & Main
Burner Flames
ON
Closed, CPI
Opened
Pilot-ON
Pilot Flame ON
Closed, CPI
Closed
Turn-ON
Pilot & Main
Burner Flames
ON
Command Definitions
REMOTE CONTROL
OPERATION
WARNING: Make sure the remote handset
switch is in the OFF position when you are away
from home for long periods of time. Heater may
come on automatically with remote receiver
switch in the “THERMOSTAT” position.
CAUTION: Do not try to adjust heating
levels by using the equipment shutoff
valve.
1. Set the IPI/CPI pilot mode switch to the CPI posi -
tion (switch closed). At that point the unit will im-
mediately ignite the pilot
flame.
The pilot
flame
will
remain ON.
Note:
If pilot does not stay lit, contact a qualif-
ied service person or gas supplier for repairs.
Turning ON the Appliance
1.
Press the Burner System
ON/OFF
switch into the
ON
position.
This will cause the main burner to ignite.
Turning OFF the Appliance
1. Slide the remote receiver switch to the OFF position.
This will turn off the main burner.
Note:
If the
Continuous
Pilot
Ignition
mode is sel-
ected the pilot
fl
ame will remain
ON
. To turn the pilot
fl
ame completely
OFF
, switch the appliance into
Inter-
mittent Pilot Ignition
mode and set the
IPI/CPI
pilot mode switch to the
IPI
position (switch opened).
Note:
You may be running this heater for the first
time after hooking up to gas supply. If so, the control
switch may need to be pressed in more than one time.
This will allow air to bleed from the gas system.
Figure 18 - Remote Receiver Switch in ON Position
TO TURN OFF GAS
TO APPLIANCE
1.
Turn off all electric power to the appliance (remove bat-
teries) if service is to be performed.
Initializing the System for the First Time
(IPI/CPI Switch In CPI Position)
OPERATING LOG SET
Continued
LEARN
HI/LOW ON/OFF
I
I
0
2. Set flame to high or low setting with HI/LOW switch
or HI/MED/LOW with remote handset.
Follow instructions under
USING THE LEARN FUNCT-
ION, Page 10
KEY SETTINGS
1. ON - - -
2. OFF - -
3. MODE
4. SET - -
Turns appliance on
Turns appliance off
Cycles control between manual and thermo-
Sets temperature in thermostat mode.
stat mode.
Press the
ON
key to turn the appliance on. (
The flame
-
icon will appear on the LCD screen).
ON
MODE
OFF
SET
1
2
3
4
Figure 19 - Remote Handset Switch Functions
To Turn Burner ON
To Turn Burner OFF
Press the
OFF
key to turn the appliance off.(
The flame
icon will disappear from the LCD screen).
THERMOSTAT FUNCTION
Press the
MODE
key until the LCD screen shows the
To adjust set temperature, press and
hold the
SET
key until the desired temperature is reached.
The temperature range is 99ºF (32ºC) to 45ºF (6ºC).
The LCD screen will display the set temperature for 3 sec-
onds, then it will flash the set temperature for 3 seconds. I
t
will default to show the room temperature. The flame i
con
will appear when the control calls for heat.
The flame icon will disappear when the appliance reac
hes
its set temperature.
word
“ROOM.”