OPERATING LOG SET

FOR YOUR SAFETY

READ BEFORE

OPERATING

 WARNING: If you do not follow these 

instructions exactly, a 

re or explosion may 

result causing property damage, personal 

injury or loss of life.

A.  This appliance is equipped with an ignition device 

which automatically lights the pilot. 

Do Not

 try to 

light the pilot by hand.

B.  BEFORE LIGHTING smell all around the appli-

ance area for gas. Be sure to smell next to the 

floo

because some gas is heavier than air and will settle 

on the floo

r.

  WHAT TO DO IF YOU SMELL GAS

•  Do not try  to light any appliance.

•  Do not touch  any electric  switch;  do not

  use any phone in your building.

•  Immediately  call your  gas supplier  from  a neigh-

bor’s phone. Follow the gas supplier’s instruc-

tions.

•  If you cannot  reach  your  gas supplier,  call the

department.

C.  Main gas valve in this appliance is not serviceable 

and does not have any control knobs or switches to 

operate. Do not remove heat shields covering the 

valve and  electronic  devices; do not try  to repair or

 

modify the valve as it may result  in a fire or explo-

sion. Call a qualified  service technician  if you

 

have

any safety concerns. 

D.  Do not use this appliance if any part has been under 

water.  Immediately call a qualified  service  techni-

cian to inspect the appliance and to replace any part 

of the control system and any gas control which has 

been under water.

Figure 9a - Burner System Receiver Switch in OFF 

                     Position

8. Wait five (5)  minutes  to clear out any gas. Then 

smell for gas, including  near the floor. If you smell 

gas, STOP!  Follow “B” in the safety information.  

If you don’t  smell gas, go to the next step.
Note: Before applying any power supply to the Module 

board,  please verify that  the electrical  connections  

are  in accordance  to the 

 Wiring Diagram  

Figure 24,

 

page 21.

 

 

 the appliance  will not operate,  follow the instructions

 “To Turn  Off Gas To Appliance”  and  call your service

 

 technician or gas supplier. 

Initializing the System for the First Time

1.  Set the ON/OFF switch to the ON position. (See Fig-

ure 9b) 

Figure  9b  -  Burner System  Switch  in  ON 

Position

LEARN

HI/LOW ON/OFF

I

I

0

IPI/CPI SWITCH

The burner system can be operated in either IPI (int-

ermittent Pilot Ignition) or CPI (continues Pilot Ign-

ition) modes. In IPI mode the pilot lights each time 

the burner system is operated. In CPI mode the ODS

Pilot stays on and the burner is turned ON and OFF 

with the switch or remote handset.

The IPI/CPI switch is on he right side of the burner 

system, near the front log.

OPERATING

INSTRUCTIONS

1. 

STOP!

 Read  the safety information,  starting  on page 2.

2.  Turn  off all electric  power  to the appliance.
3.  Do not attempt to light the pilot by hand.

4.

 

Turn main shutoff valve counterclockwise             to 

the ON position.

5.  Set Burner System  Receiver switch to OFF position.

7.   Locate Burner System

 

controls on the right front

 

 

 (see

Figure 15,

 

page 12. Make  sure  that  the ON/OFF   

   

switch  f o r   t h e   b u r n e r   is  in the OFF position. 

(see 

Figure 9a

)

LEARN

HI/LOW ON/OFF

I

I

0

(IPI/CPI Switch In IPI Position)

The unit will proceed to ignite the pilot, and then the main 

burner and will operate in the HIGH setting.

If

Содержание AEVF18FALP

Страница 1: ...l with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local cod...

Страница 2: ...e explosion electrical shock and carbon monoxide poisoning WARNING Any change to this heater or its controls can be dangerous WARNING Do not allow fans to blow directlyintotheappliance Avoidanydrafts...

Страница 3: ...ty shutoff system The ODS shuts down the replace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages...

Страница 4: ...t can be used to turn the log set on and off The thermostat setting can also be selected Thermostat setting senses the room temperture at the location of the remote handset The thermostat will automat...

Страница 5: ...ing uncon ned space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the oor on the wall connecting the two spaces see Figure 1 You can also remove door into a...

Страница 6: ...nts to the outdoors Example Vent free log set ______________ Btu Hr Gas water heater _____________ Btu Hr Total ________ Btu Hr 4 Compare the maximum Btu Hr the space can support with the actual amoun...

Страница 7: ...oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is bene cial installing appliance in rooms without enough ventilation ai...

Страница 8: ...could occur For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If...

Страница 9: ...end that you install a sediment trap in supply line as shown in Figure 6 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate se...

Страница 10: ...ane LP Apply noncorrosive leak detection uid to all joints Bubbles forming show a leak 4 Correct all leaks at once BATTERY INSATLLATION Batteries must be installed in the appliance for it to funct ion...

Страница 11: ...Log Placement American Elm 18 Models 11...

Страница 12: ...Log Placement American Elm 24 Models 12...

Страница 13: ...clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step Note Before applying any power supply...

Страница 14: ...n switch opened Note You may be running this heater for the first time after hooking up to gas supply If so the control switch may need to be pressed in more than one time This will allow air to bleed...

Страница 15: ...Gas To Log Set page 14 see Troubleshooting pages 17 through 20 If burner flame pattern is incorrect as shown in Figure 23 you should turn heater off see To Turn Off Gas To Appliance page 14 Refer to...

Страница 16: ...s on the can you could damage the pilot assembly Figure 23 Injector Holder On Outlet Burner Tube 1 Shut off the unit including the pilot Allow the unit to cool for at least 30 minutes 2 Inspect burner...

Страница 17: ...pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Call for service 5 Replace pilot assembly 6 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve...

Страница 18: ...ocal natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 16 7 Replace pilot assembly Replace control valve 1 Clean burner ori ce see Cleaning and Maintenance page 16...

Страница 19: ...lean ers or similar products 1 This is normal with most log sets If noise is exces sive contact a quali ed service person 1 Refer to Air For Combus tion and Ventilation require ments page 4 1 Disconti...

Страница 20: ...chemicals new carpet etc see IMPOR TANTstatement above 2 Low fuel supply propane LP gas only 3 Gas leak See Warning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3...

Страница 21: ...operate the gas valve to the OFF position How to Clear Cycle ON OFF switch to OFF position Two beeps per second Automatic Recycle Description of Fault Pilot is proven and lost 3 times within 2 minute...

Страница 22: ...1 2 3 4 5 6 7 8 9 10 11 11 L 12 13 14 15 16 17 18 22 ILLUSTRATED PARTS BREAKDOWN S B VFA FULLY AUTO MODELS...

Страница 23: ...RMH 120 584912 RMH 120 584912 1 Nut ODS Mounting RMH 120 00051 RMH 120 00051 RMH 120 00051 RMH 120 00051 2 Screw Hex 8 X 3 8 RMH 122 00625 49738375 49738375 49738375 6 Decorative Rock WIP 130 00050 W...

Страница 24: ...discoloring of any kind use or installation contrary to specified instructions and applicable building codes including heating the product to temperatures above its rated speci cations which can caus...

Отзывы: