Item

Part Description

          Part Number

Qty.

S,BVFA18NG

S,BVFA18LP

S,B VFA24NG

S,BVFA24LP

1

Main Support Assembly

RMH-120-LLC18

RMH-120-LLC18

RMH-120-LLC24

RMH-120-LLC24

1

2

Dual Burner

RHM-120-01120

RHM-120-01120

RHM-120-01430

RHM-120-01430

1

3

Air Shutter, Burner

RMH-120-00260

RMH-120-00254

RMH-120-00260

RMH-120-00254

1

4

Gas Control Valve 

RMH-120-00152NGMR RMH-120-00152LPMR RMH-120-00152NGMR RMH-120-00152LPMR

1

5

Heat Shield

RMH-120-COPHS

RMH-120-COPHS

RMH-120-COPHS

RMH-120-COPHS

1

6

Module Bracket

RMH-120-COPMB

RMH-120-COPMB

RMH-120-COPMB

RMH-120-COPMB

1

7

Module Board

RMH-120--ECOMOD

RMH-120--ECOMOD RMH-120--ECOMOD RMH-120--ECOMOD

1

8

Switch Plate  (Batt Box)

RMH-120-SWP/BB

RMH-120-SWP/BB

RMH-120-SWP/BB

RMH-120-SWP/BB

1

9

Pilot, ODS

RMH-120-57827

RMH-120-7818

RMH-120-57827

RMH-120-7818

1

10

Tube, ODS Pilot

RMH-120-90434A

RMH-120-90434A

RMH-120-90434A

RMH-120-90434A

1

11

Burner Clip

SBNCJ00071A

SBNCJ00071A

SBNCJ00071A

SBNCJ00071A

2

12

Pipe Nipple

RMH-120-90860

RMH-120-90860

RMH-120-00048

RMH-120-00048

1

13

Regulator

RMH-120-COPNG

RMH-120-00222

RMH-120-COPNG

RMH-120-00222

1

14

Connection Tube

KHH-ACT16

KHH-ACT16

KHH-ACT16

KHH-ACT16

1

15

Remote Handset

RMH-120-1001TH

RMH-120-1001TH

RMH-120-1001TH

RMH-120-1001TH

1

16

Fitting 1/2" NPT X 3/8" Flr

SH-111

SH-111

SH-111

SH-111

1

17

Orifice Tube

RMH-120-FABST

RMH-120-FABST

RMH-120-FABST

RMH-120-FABST

1

18

Switch, ON/OFF and HI/LO

RMH-120-68513

RMH-120-68513

RMH-120-68513

RMH-120-68513

                                                                      Parts available but not shown

Wire, Flame Sensor

8600338

8600338

8600338

8600338

1

Wire, Igniter

RMH-120-840000020 RMH-120-840000020 RMH-120-840000020 RMH-120-840000020

1

Wire harness - Valve

RMH-120-584912

RMH-120-584912

RMH-120-584912

RMH-120-584912

1

Nut, ODS Mounting

RMH-120-00051

RMH-120-00051

RMH-120-00051

RMH-120-00051

2

Screw, Hex 8 X 3/8

RMH-122-00625

49738375

49738375

49738375

6

Decorative Rock

WIP-130-00050

WIP-130-00050

WIP-130-00050

WIP-130-00050

1

REPLACEMENT PARTS

Note:

  Use  only  original  replacement  parts.  This  will 

protect your warranty coverage for parts replaced under 

warranty. 

Parts Under Warranty

Contact authorized dealers of this product. If they can’t

 

sup-

ply original replacement part(s), call Sure Heat Manufact-

 

 

uring Technical Service Department at (800) 229-5647.
When calling Customer Service, have ready:
•  your name
•  your address
•  model and serial numbers of your heater
•  how appliance was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t

supply original replacement part(s), call SHM International 

at (800) 229-5647 for referral information. When calling 

Sure Heat Manufacturing, have ready:

•  model number of your appliance
•  the replacement part number

SERVICE HINTS

When gas pressure is too low:
•  pilot will not stay lit
•  heater will not produce specified heat
•  propane/LP gs supply may be low
You may feel your gas pressure is too low. If so, contact 

your local natural or propane/LP gas supplier. 

Note:

  Use  only  original  replacement  parts.  This  will 

protect your warranty coverage for parts replaced under 

warranty. 

TECHNICAL SERVICE

You may have further questions about installation, opera-

tion or troubleshooting. If so, contact Sure Heat Manufact-

 

uring Technical Service Department at (800) 229-5647.
When  calling  please  have  your  model  and  serial 

numbers  of  your  heater  ready.  You  can  also  visit 

SHM  International’s  Technical  Service  web  site  at  

www.sureheat.com.

SERVICE INFORMATION

(S,B)VFA FULLY AUTO MODELS

PARTS LIST KEY

Содержание AEVF18FALP

Страница 1: ...l with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local cod...

Страница 2: ...e explosion electrical shock and carbon monoxide poisoning WARNING Any change to this heater or its controls can be dangerous WARNING Do not allow fans to blow directlyintotheappliance Avoidanydrafts...

Страница 3: ...ty shutoff system The ODS shuts down the replace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages...

Страница 4: ...t can be used to turn the log set on and off The thermostat setting can also be selected Thermostat setting senses the room temperture at the location of the remote handset The thermostat will automat...

Страница 5: ...ing uncon ned space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the oor on the wall connecting the two spaces see Figure 1 You can also remove door into a...

Страница 6: ...nts to the outdoors Example Vent free log set ______________ Btu Hr Gas water heater _____________ Btu Hr Total ________ Btu Hr 4 Compare the maximum Btu Hr the space can support with the actual amoun...

Страница 7: ...oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is bene cial installing appliance in rooms without enough ventilation ai...

Страница 8: ...could occur For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If...

Страница 9: ...end that you install a sediment trap in supply line as shown in Figure 6 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate se...

Страница 10: ...ane LP Apply noncorrosive leak detection uid to all joints Bubbles forming show a leak 4 Correct all leaks at once BATTERY INSATLLATION Batteries must be installed in the appliance for it to funct ion...

Страница 11: ...Log Placement American Elm 18 Models 11...

Страница 12: ...Log Placement American Elm 24 Models 12...

Страница 13: ...clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step Note Before applying any power supply...

Страница 14: ...n switch opened Note You may be running this heater for the first time after hooking up to gas supply If so the control switch may need to be pressed in more than one time This will allow air to bleed...

Страница 15: ...Gas To Log Set page 14 see Troubleshooting pages 17 through 20 If burner flame pattern is incorrect as shown in Figure 23 you should turn heater off see To Turn Off Gas To Appliance page 14 Refer to...

Страница 16: ...s on the can you could damage the pilot assembly Figure 23 Injector Holder On Outlet Burner Tube 1 Shut off the unit including the pilot Allow the unit to cool for at least 30 minutes 2 Inspect burner...

Страница 17: ...pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Call for service 5 Replace pilot assembly 6 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve...

Страница 18: ...ocal natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 16 7 Replace pilot assembly Replace control valve 1 Clean burner ori ce see Cleaning and Maintenance page 16...

Страница 19: ...lean ers or similar products 1 This is normal with most log sets If noise is exces sive contact a quali ed service person 1 Refer to Air For Combus tion and Ventilation require ments page 4 1 Disconti...

Страница 20: ...chemicals new carpet etc see IMPOR TANTstatement above 2 Low fuel supply propane LP gas only 3 Gas leak See Warning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3...

Страница 21: ...operate the gas valve to the OFF position How to Clear Cycle ON OFF switch to OFF position Two beeps per second Automatic Recycle Description of Fault Pilot is proven and lost 3 times within 2 minute...

Страница 22: ...1 2 3 4 5 6 7 8 9 10 11 11 L 12 13 14 15 16 17 18 22 ILLUSTRATED PARTS BREAKDOWN S B VFA FULLY AUTO MODELS...

Страница 23: ...RMH 120 584912 RMH 120 584912 1 Nut ODS Mounting RMH 120 00051 RMH 120 00051 RMH 120 00051 RMH 120 00051 2 Screw Hex 8 X 3 8 RMH 122 00625 49738375 49738375 49738375 6 Decorative Rock WIP 130 00050 W...

Страница 24: ...discoloring of any kind use or installation contrary to specified instructions and applicable building codes including heating the product to temperatures above its rated speci cations which can caus...

Отзывы: