![Sur-Gard SG-DV4420 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/sur-gard/sg-dv4420/sg-dv4420_manual_1406534009.webp)
9
PROGRAMMING - GETTING STARTED
When the connection is established the SG-DV4420
will identify itself on the display as follows:
P R O G R A M M I N G M O D E
P R O G R A M M I N G M O D E
P R O G R A M M I N G M O D E
P R O G R A M M I N G M O D E
P R O G R A M M I N G M O D E
and
SG-DV4420 V1.0
SG-DV4420 V1.0
SG-DV4420 V1.0
SG-DV4420 V1.0
SG-DV4420 V1.0
C O N N E C T I N G . . .
C O N N E C T I N G . . .
C O N N E C T I N G . . .
C O N N E C T I N G . . .
C O N N E C T I N G . . .
... CONNECTED
... CONNECTED
... CONNECTED
... CONNECTED
... CONNECTED
At this point the connection is complete and the SG-
DV4420 is ready to accept programming commands
from the SG-DVT1. The SG-DVT1 is in programmer mode
and will prompt you with the following message:
Prog. all data ?
Prog. all data ?
Prog. all data ?
Prog. all data ?
Prog. all data ?
YES NO EXIT
YES NO EXIT
YES NO EXIT
YES NO EXIT
YES NO EXIT
ENT
SEL1 SEL2
At this message you can select if all data needs to be
programmed (press [ENT] to go in the programming all
data mode) or just selected few (press [SEL1] to go in
the programming selected data mode). You may also
select EXIT option to quit programmer mode by pressing
the [SEL2] button.
PROGRAMMING ALL DATA MODE
Press [ENT] to programm all data.
Prog. all data ?
Prog. all data ?
Prog. all data ?
Prog. all data ?
Prog. all data ?
YES NO EXIT
YES NO EXIT
YES NO EXIT
YES NO EXIT
YES NO EXIT
ENT
SEL1 SEL2
When [ENT] is pressed to select YES, the SG-DV4420
will ask if you want to reset all data to defaults with the
following message:
Reset ALL Data ?
Reset ALL Data ?
Reset ALL Data ?
Reset ALL Data ?
Reset ALL Data ?
NO YES EXIT
NO YES EXIT
NO YES EXIT
NO YES EXIT
NO YES EXIT
ENT
SEL1 SEL2
Press [ENT] if reset to defaults is not required or press
[SEL1] to reset data to defaults. You may also select
EXIT option to return to the programmer mode by
pressing the [SEL2] key.
If you press [SEL1], then the SG-DV4420 will prompt
you to go ahead with reset to factory defaults with the
following message:
ARE YOU SURE ?
ARE YOU SURE ?
ARE YOU SURE ?
ARE YOU SURE ?
ARE YOU SURE ?
NO YES EXIT
NO YES EXIT
NO YES EXIT
NO YES EXIT
NO YES EXIT
ENT
SEL1 SEL2
Press [SEL1] to confirm or press [ENT] or [SEL2] to abort
the operation. If you press [ENT], the SG-DV4420 will go
to the Programming All Data Mode. If you press [SEL2],
the SG-DV4420 will return to the programmer mode. If
[SEL1] is pressed, the SG-DV4420 will prompt you with
the following message if the operation was aborted:
W r i t i n g F a c t o r y
W r i t i n g F a c t o r y
W r i t i n g F a c t o r y
W r i t i n g F a c t o r y
W r i t i n g F a c t o r y
and
Writing COMPLETE
Writing COMPLETE
Writing COMPLETE
Writing COMPLETE
Writing COMPLETE
Defaults, Wait
Defaults, Wait
Defaults, Wait
Defaults, Wait
Defaults, Wait
S 1 = D I G 1 S 2 = D I G 2
S 1 = D I G 1 S 2 = D I G 2
S 1 = D I G 1 S 2 = D I G 2
S 1 = D I G 1 S 2 = D I G 2
S 1 = D I G 1 S 2 = D I G 2
A D D R = 0 0 D A T A = 0
A D D R = 0 0 D A T A = 0
A D D R = 0 0 D A T A = 0
A D D R = 0 0 D A T A = 0
A D D R = 0 0 D A T A = 0 1
1
1
1
1
The SG-DV4420 has it’s own EEPROM which is used
to keep in memory all the installer programming and
that won’t erase in case of power failure.
All programming must be done according to the
standards and requirements of the central station to
which this equipment is connected, and according to
the restrictions of Underwriters' Laboratories of
Canada, if applicable.
The system ID code and other programmable parameters
can be changed in the EEPROM by using the SG-DVT1
Tester (with program version 5.0 or later) as an access
terminal. The SG-DVT1 is plugged into the SCHED-3A
line modular socket. The program select jumper J2 should
be temporarily removed.
TRANSFER OF DEFAULTS TO THE EEPROM
(Hardware Reset of EEPROM to Factory Defaults). Use
the following procedure:
1. Power down the SG-DV4420 by removing both AC
and battery power.
2. Using a Plug-In jumper borrowed from J2, short pins
marked EEPROM RESET J1 together.
3. Power up the SG-DV4420 and wait approx. 5 seconds.
4. Remove the Plug-In jumper.
PROGRAMMING WITH THE SG-DVT1
Connect a SG-DVT1 (version 5.0 or more) to the SG-
DV4420 (see figure #3). Unplug the modular cable
connected to modem and connect it to SG-DVT1
transmitter jack (XTR).
Power up the SG-DVT1 Tester by connecting it to the
control panel battery using the two alligator clip (make
sure to respect the right polarities).
At the power up the SG-DVT1 display shows:
SELECT MODE V5.0
SELECT MODE V5.0
SELECT MODE V5.0
SELECT MODE V5.0
SELECT MODE V5.0
NOW: SCAN MODE
NOW: SCAN MODE
NOW: SCAN MODE
NOW: SCAN MODE
NOW: SCAN MODE
ENT
SEL1 SEL2
Select the “PROG MODE” on the SG-DVT1 by Pressing
[SEL1] twice. The SG-DVT1 screen should be as follows:
SELECT MODE V5.0
SELECT MODE V5.0
SELECT MODE V5.0
SELECT MODE V5.0
SELECT MODE V5.0
NOW: PROG MODE
NOW: PROG MODE
NOW: PROG MODE
NOW: PROG MODE
NOW: PROG MODE
START PROGRAMMER MODE
Press [ENT] to start the programmer mode. The SG-
DVT1 will initiate the handshake with the SG-DV4420.
SELECT MODE V6.0
SELECT MODE V6.0
SELECT MODE V6.0
SELECT MODE V6.0
SELECT MODE V6.0
NOW: PROG MODE
NOW: PROG MODE
NOW: PROG MODE
NOW: PROG MODE
NOW: PROG MODE
ENT
SEL1 SEL2
Содержание SG-DV4420
Страница 6: ...6 SG DV4420 WIRING DIAGRAM N O T USED 14VAC 20VA 14V 14V 14V 14V 14VA C A C A C A C A C...
Страница 7: ...7 F1 F2 SUBSET CONNECTION DIAGRAM...
Страница 8: ...8 SG DVT1 CONNECTION DIAGRAM...
Страница 17: ...17 APPENDIX A SG DS1 WIRING DIAGRAMS...
Страница 18: ...18 APPENDIX B SG DV4420 PROGRAMMING FLOW CHART V6 0 V6 0 V6 0...
Страница 21: ...INSTRUCTION MANUAL SG DV4420 Software Version 1 1...
Страница 23: ...24...