27
E6zz
Expand trouble station ID zz (zz=17-31)
EEzz
Expand restore station ID zz (zz=17-31)
E100
Automatic test
E2zz
Manual test zone ZZ
F000
Automatic closing
F400
Automatic opening
F1zz
: Normal closing ID ZZ
F5zz
: Normal opening ID ZZ
F2zz
: Forced closing ID ZZ
F6zz
: Forced opening ID ZZ
F3zz
: Supervised closing ID ZZ
F7zz
: Supervised opening ZZ
FD0a
: Closing area 0a
FF0a
: Opening area 0a
F8zz
: Access
F9zz
: Access left open ID zz
FAzz
: Access forced ID ZZ
FBzz
: Access station ID ZZ
FC00
: Duress
FE00
: Data lost
7.14 SESCOA SUPER SPEED
Sescoa Super Speed is a 40 Baud communication for-
mat. Account codes are programmed as 4-digit deci-
mal codes ranging from 0001 to 3374. The account
code is followed by a 1-digit event code, a 2-digit
alarm code, and 1-digit checksum.
Option [A5] must be programmed as “01” in order to
use Sescoa Super Speed decoding instead of 4/2 with
checksum decoding.
Example:
Printer: L01-1234—LOW BATT HH:MM:SS-DD/MM
Computer: 7017ssssss1234sF
7.15 DRL2E Predefined Library Decoding and
Event Codes Table
7.15.1 3/1 - 4/1 Alarm Library
7.15.2 3/1-4/1 Extended, 3/2 & 4/2 Alarm Library
7.15.3 4/2 Extended & 4/3 Alarm Library
Ensure that the central station automation software is able
to accept these codes if they are to be used.
7.15.4 Event Codes Summary
Code
Event
0
Automatic Test
1
Fire Alarm
2
Panic Alarm
3
Burglary Alarm
4
Closing by User Number
5
Opening by User Number
6
Service
7
Medical Emergency
8
Message
9
Restore
A
Alarm
B
Bypass
C
Closing
D or /
Cancel
H
Unbypass
O
Opening
R
Restore
T
Trouble
Z
Common Event Code
20 Hex Common Event code “Space”
For Alarm
Message
Corresponding
Code
Event
Code (Options 30-3F)
0 (A)
A
PER TEST REPORT
1
A
FIRE ALARM
2
A
PANIC ALARM
3
A
BURGLARY
4
A
GENERAL ALARM
5
A
GENERAL ALARM
6
A
GENERAL ALARM
7
A
MEDICAL
8
A
SYSTEM TROUBLE
Restore
9
R
RESTORE
Open
B
O
OPENING
Close
C
C
CLOSING
Cancel
D
/
CANCEL
Restore
E
R
RESTORE
Trouble
F
T
SYSTEM TROUBLE
Alarm
0x (Ax)
A
PER TEST REPORT
Alarm
1x
A
FIRE ALARM
Alarm
2x
A
PANIC ALARM
Alarm
3x
A
BURGLARY
Alarm
4x
A
GENERAL ALARM
Alarm
5x
A
GENERAL ALARM
Alarm
6x
A
GENERAL ALARM
Alarm
7x
A
MEDICAL
Alarm
8x
A
SYSTEM TROUBLE
Restr
9x
R
RESOTRE
Open
Bx
O
OPENING
Close
Cx
C
CLOSING
Cancl
Dx
/
CANCEL
Restr
Ex
R
RESTORE
Trble
Fx
T
SYSTEM TROUBLE
Alarm
0xx(Axx)
T
0
PER TEST REPORT
Alarm
1xx
A
1
FIRE ALARM
Alarm
2xx
A
2
PANIC ALARM
Alarm
3xx
A
3
BURGLARY
Close
4xx
C
4
CLOSING
Open
5xx
O
5
OPENING
Alarm
6xx
T
6
SERVICE
Alarm
7xx
A
7
MEDICAL
Alarm
8xx
A
8
MESSAGE
Restr
9xx
R
9
RESTORE
CloseGrp
Bxx
C
C
OPENING
OpenGrp
Cxx
O
O
CLOSING
Bypas
Dxx
B
B
CANCEL
Unbyp
Exx
H
H
RESTORE
Cancl
Fxx
/
/
SYSTEM TROUBLE
Содержание MLR2E
Страница 2: ......