Страница 1: ...English Version 2 2 Xpass S2 INSTALLATION GUIDE www supremainc com EN 101 00 XPS2 V2 20A...
Страница 2: ...ton Door sensor 10 Digital input connection Door button Door sensor 10 Digital input connection Alarm Emergency switch 10 Connecting to a Relay 11 Fail Safe Lock 11 Fail Secure Lock 11 Connecting to a...
Страница 3: ...rvice fee will be charged for repair Operating Instructions Be careful not tospill any liquid suchas water drinks or chemicals inside the product This can cause fire electric shock or product damage C...
Страница 4: ...ted 4 Getting Started Components The components may differ dependingon where the product is installed Note Xpass S2 Main bracket Adapter Mounting screws for bracket 2 pcs PVC anchors 2 pcs Heat shrink...
Страница 5: ...2 seconds An IP address has not been received when DHCP is set to USE Red flashes every 2 seconds on first use Failure to reset Contact the manufacturer Yellow flashes briefly Waiting for an input RF...
Страница 6: ...G D0 Green 5 WG D1 White 6 TTL IN0 Purple 7 TTL IN1 Brown 8 485TRXP Blue White stripe 9 485TRXN Yellow Black stripe 10 ENETTXN Red 11 ENETTXP Black 12 ENET RXN Yellow 13 ENET RXP Green 14 PWR GND Blac...
Страница 7: ...nto the surface where Xpass S2 is to be installed If Xpass S2 should be installed onto a concrete wall make a hole with a drill and then insert a PVC anchor into the hole before screwing the mounting...
Страница 8: ...the screws included with the extension bracket 2 Mount the assembled extension bracket onto the desired place with the mounting screws for the bracket 3 Attach Xpass S2 onto the mounted extension brac...
Страница 9: ...supply for Secure I O 2 electric lock and Xpass S2 respectively If connecting and using the power supply to these devices together the devices may malfunction Connecting to a Network TCP IP LAN conne...
Страница 10: ...al input connection Door button Door sensor Digital input connection Alarm Emergency switch Xpass S2 Input 1 2 7 2 6 Input 0 2 TTL GND Gray 6 TTL IN0 Purple 7 TTL IN1 Brown 2 TTL GND Gray 6 TTL IN0 Pu...
Страница 11: ...lockdevice Fail Secure Lock To use fail secure lock connect N O terminal as shown below Normally there is no current flowing through the relay and the door is opened when the relay is activated by a c...
Страница 12: ...nsor Door Input 1 Relay Input 0 2 7 17 16 2 6 Xpass S2 2 TTL GND Gray 6 TTL IN0 Purple 7 TTL IN1 Brown 16 RLY COM Green White stripe 17 RLY NC Orange White stripe PC 15 RLY NO Gray White stripe 16 RLY...
Страница 13: ...the performance in communicating will deteriorate because it reduces the signal level Up to 32 devices can be connected via daisy chain 1 master device and 31 other devices Connecting as a Wiegand de...
Страница 14: ...485 PC connection 115200 bps 4 Change theTCP IP address or RS 485 information 5 Turn the power off later on and then check the network setting is properly Restoring the Factory Defaults This will del...
Страница 15: ...x User 1 1 50 000 Max User 1 N 50 000 Max Text Log 100 000 Interface TCP IP Yes RS 485 1ch Host or Slave Selectable Wiegand 1ch In or Out Selectable TTL Input 2 Inputs Relay 1 Relay Relay Voltage Max...
Страница 16: ...Product Specifications 16 Dimensions Unit mm Front view Extension bracket Main bracket Side view...
Страница 17: ...f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular insta...
Страница 18: ...employees subsidiaries branches partners and distributors of Suprema are exempt from liability even when it is claimed that there is a significant fault in the design or production process and also t...