INSTALLATION INSTRUCTIONS
Dimensions
Free membrane area: 0.2 m²
Materials:
Membrane:
EPDM (ethylene propylene diene rubber)
TPU (thermoplastic polyurethane)
Base plate:
Polypropylene (PP-GF)
Frame:
Polypropylene (PP-GF)
Gaskets:
EPDM
The distance between the diffusers on the distribution pipe (connection hole axis) should be at least 280 mm and
must not exceed 1,000 mm (differences possible on request).
In the vicinity of the mixer, optional side
brackets provide additional stability and make
area-wide coverage possible in this case as
well (independently of the type of installation
on round or square distribution pipes).
Storage
Store the diffusers in their packaging in a dry
and ventilated room.
DIN 7716 provisions must be observed.
Preparation
Prior to installing the OXYFLEX
®
- MF1100 membrane plate diffuser it must be ensured that the pipelines are clean.
All drilling chippings, dirt, etc. must be removed, otherwise they will be carried into the diffuser when the fan is
started up and could cause significant impairment or damage.