USE

- Unwind the cable completely before connecting it.

- Connect the unit to the mains.

- Position the unit to direct the air flow in the desired direction.

- Switch the unit on by pressing the on/off button(

h

).

Commandes faciles à utiliser

Suitable for 20 m².

An economical way to combat mildew, condensation and moisture.

Dries clothes more efficiently than a tumble dryer.

Designed to fit into any modern space

Castors for easy mobility

Intelligent CPU-controlled digital humidistat with display of room humidity and relative humidity 

between 35 and 80%.

24 hour start/stop timer

Tank operation or permanent drainage option with anti-splash tank Full tank alarm and auto shut-off 

function

1.
2.
3.
4.
5.
6.
7.

8.
9.

g. Power button to turn on/

off the unit

e.

MODE 

button

Selects the function of the appliance between ECO and FAN modes. The

LEDs next to the button indicate the selected mode. ECO MODE : The

appliance defaults to ECO mode when first switched on and remains in this

mode until another programme is selected.

another programme is selected. In ECO mode, it defaults to a relative

humidity of 50-55%.

Air purifier: Only the fan operates and no water is extracted.

a. HUMIDITY CONTROL

Press the UP and DOWN buttons to select the desired relative humidity

level, the default relative humidity is 55%. When a relative humidity of

35% is selected, the compressor does not stop until the water tank is

full.

a. HUMIDITY INDICATOR button

When the appliance is switched on, the indicator light comes on

automatically. The colour of the indicator light changes according

to the humidity conditions.

RED: High humidity, RH≥70%.

ORANGE: Comfortable, 70%> RH ≥60%.

GREEN: Dry, RH<60%

It is possible to press the "Humidity indicator light" button to turn

on/off the indicator light. Note: It may take about 2 minutes after

the humidity has changed colour support for the indicator to

change colour, for example, if the humidity drops to 55%, it may

take 2 minutes for the indicator to turn green.

f.

 UV LIGHT

 (air purification function)

To activate the UV function, press the "UV" button and the indicator light will 

illuminate. The germicidal UV light will destroy germs, bacteria and fungi, thus 

improving the indoor air quality.
b. 

TIMER

Press the TIMER button to set the timer. When the timer is activated, the 

"TIMER" indicator lights up. Before programming the timer, make sure that the 

timer function has not been activated (the indicator should be off). The following 

timer programs are available. DELAY TIMER FUNCTION: When the appliance 

is in standby, press the TIMER button, then use the UP and DOWN buttons to 

set the number of hours you want the appliance to turn on (1~24 hours). 

DELAYED POWER OFF FUNCTION: When the unit is running with the desired 

settings, press the TIMER button, then use the UP and DOWN buttons to set the 

number of hours you want the unit to shut down (1~24 hours).

INTELLIGENT DEFROST

The appliance defrosts automatically when the coil sensor detects 

that the internal temperature is too low. During defrosting, the 

indicator lights up. When the defrost cycle is complete, the unit 

returns to the previous operating mode.

TANK FULL

When the water tank is full, the FULL TANK indicator light will flash 

and the appliance will stop working. Once emptied and replaced, the 

appliance will start working again.
optional charcoal filter (air purification function) Remove the charcoal 

filter from its bag and insert it into the filter housing. It is suggested to 

vacuum the charcoal filter every 2-3 weeks and change it every 3-6 

months to ensure that the room remains fresh and odour free.

HUMIDITY LEVEL & TIMER 2-DIGIT DISPLAY The LED indicator performs 

the following functions:

1. When the unit is switched on, it indicates the humidity level in the room.

2. When the UP and DOWN buttons are pressed, the unit indicates the desired humidity level.

3. When the timer is programmed, it will indicate the time.

Notes: When the humidity level is outside the normal operating parameters, the display will show LO/HI. If the ambient humidity is 

below 20%, the message "LO" will be displayed. If the ambient humidity is above 90%, the message "HI" will be displayed.

c. d. 

Buttons to adjust the

humidity level

Содержание DU100 RESPIRE

Страница 1: ...DU100 RESPIRE...

Страница 2: ...Panneau de contr le D Poign e E Roulettes F Entr e d air G Orifice de drainage continu H C ble d alimentation I Pr filtre filtre charbon actif J R servoir d eau K Filtre charbon actif optionnel a Ind...

Страница 3: ...our activer la fonction UV appuyez sur le bouton UV et le t moin lumineux s allume La lumi re UV germicide d truira les germes les bact ries et les champignons am liorant ainsi la qualit de l air int...

Страница 4: ...ICATEURS DE R SERVOIR PLEIN Lorsque le r servoir d eau est plein retir ou mal ins r l appareil cesse de d shumidifier le voyant rouge de r servoir plein s allume et l appareil met un bip Videz le r se...

Страница 5: ...tes jamais fonctionner l appareil sans que le cadre du filtre mailles soit correctement ins r 2 2 NETTOYER LE R SERVOIR D E Toutes les quelques semaines nettoyez le r servoir afin d viter le d veloppe...

Страница 6: ...esse toupes etc V rifier que l appareil soit mont en toute s curit V rifier que les joints d tanch it ou les mat riaux de scellage ne soient pas abim s afin d emp cher la p n tration d atmosph res inf...

Страница 7: ...isponibles Les tuyaux doivent disposer de raccords de d con nexion tanches et en bon tat Avant d utiliser la machine de r cup ration v rifier que celle ci est en bon tat de fonctionnement que l entret...

Страница 8: ...indre la pression atmosph rique Placer une tiquette sur l quipement indiquant que la proc dure de retrait du r frig rant est en cours LIMINATION Assurer une ventilation ad quate sur le lieu de travail...

Страница 9: ...icator light C Control panel D Handle E Casters F Air inlet G Continuous drainage port H Power cable I Pre filter activated carbon filter J Water tank K Activated carbon filter optional a Humidity ind...

Страница 10: ...tion function To activate the UV function press the UV button and the indicator light will illuminate The germicidal UV light will destroy germs bacteria and fungi thus improving the indoor air qualit...

Страница 11: ...INDICATORS When the water tank is full removed or incorrectly inserted the unit stops dehumidifying the red tank full indicator lights up and the unit beeps Empty the tank and reinsert it correctly t...

Страница 12: ...nk and rinse NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be securely reinserted into the dehumidifier to resume operation END OF SEASON MAINTENANCE 1 Empty a...

Страница 13: ...The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior to working on them REPAIR TO INTRINSIC...

Страница 14: ...liers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a system it shall be carried out safely COMPETENCE OF SERVICE PERSONNEL GENERAL...

Страница 15: ...nd drain the oil TRANSPORTATION MARKING AND STORAGE FOR UNITS THAT EMPLOY FLAMMABLE REFRIGERANTS TRANSPORT OF EQUIPMENT CONTAINING FLAMMABLE REFRIGERANTS Attention is drawn to the fact that additional...

Страница 16: ...humedad C Panel de control D Asas E Ruedas F Entrada de aire G Drenaje H Cable de alimentaci n I Prefiltro e filtro de carb n J Tanque K Filtro de carb n opcional a Indicador de humedad b Bot n tempor...

Страница 17: ...del aire Para activar la funci n UV pulse el bot n UV y el indicador luminoso se encender La luz UV germicida destruir los g rmenes las bacterias y los hongos mejorando la calidad del aire interior b...

Страница 18: ...CTER STICAS INDICADORES DE DEP SITO LLENO Cuando el dep sito de agua est lleno se extrae o se introduce incorrectamente la unidad dejar de deshumidificar el indicador rojo de dep sito lleno se encende...

Страница 19: ...roducirse de forma segura en el deshumidificador para reanudar el funcionamiento MANTENIMIENTO DE FIN DE TEMPORADA 1 Vaciar y limpiar el dep sito de agua 2 Limpie la unidad y los filtros seg n el proc...

Страница 20: ...da os a los cables un n mero excesivo de conexio nes terminales no hechas a la especificaci n original da os a las juntas ajuste incorrecto de los prensaestopas etc Aseg rese de que el aparato est mo...

Страница 21: ...amiento Los cilindros de recuperaci n vac os se evacuan y si es posible se enfr an antes de que se produzca la recuperaci n El equipo de recuperaci n debe estar en buen estado de funcionamiento con un...

Страница 22: ...dado de que el refrigerante drenado no cause ning n peligro En la duda una persona debe guardar la salida Tenga especial cuidado de que el re frigerante drenado no flote nuevamente dentro del edificio...

Страница 23: ...inel de controlo D Pegas E Rodas F Entrada de ar G Drenagem H Cabo de alimenta o I Pr filtro Filtro de carv o J Dep sito K Filtro de carv o activo opcional a Indicador de humidade b Bot o do temporiza...

Страница 24: ...LIGHT fun o de purifica o do ar Para activar a fun o UV prima o bot o UV e a luz indicadora acender se A luz UV germicida destruir germes bact rias e fungos melhorando a qualidade do ar interior b TIM...

Страница 25: ...TICAS INDICADORES DE TANQUE CHEIO Quando o tanque de gua estiver cheio removido ou inserido incorrectamente a unidade deixar de desumidificar o indicador vermelho de tanque cheio acender se e a unidad...

Страница 26: ...dep sito de gua 2 Limpar a unidade e os filtros de acordo com o procedimento de limpeza acima descrito 3 Enrolar o cabo de alimenta o no suporte especial de armazenamento do cabo na parte de tr s da...

Страница 27: ...de forma que o n vel de prote o seja afetado Isto inclui danos nos cabos um n mero excessivo de conex es terminais que n o seguem as especifica es de origem da nos nas juntas ajuste incorreto das caix...

Страница 28: ...quantidade correta de cilindros para reter a carga total do sistema Todos os cilindros a utilizar devem ter sido projetados para a recupera o de gases de refrigera o recuperado e etiquetados para ess...

Страница 29: ...provocar fa scas Proceda remo o do g s de refrigera o Se os regulamentos nacionais n o exigirem a recupera o drene o g s de refrigera o para o exterio Tenha cuidado para que o g s de refrigera o dren...

Страница 30: ...SUPRAFRANCE TAURUSGROUP 28 rue du G n ral Leclerc F 67216 Obernai Cedex www supra fr rev 02 06 21...

Отзывы: