1.4 WATER SUPPLYING SYSTEM
1.4.1
D
ESCRIPTION
1.4.1.1
O
VERVIEW
>The machine must be installed with a water shut-off valve, its position can not be 80cm higher
than the machine. Stop valve position must be easy to operate, so that the machine can be closed
in any time when we don't use it.
> The diameter of the drain pipe is 100 mm. In order to ensure the smooth discharge of debris,
there must be a slope of at least 5%
1.4.1.2
F
ILTER BOX WITH PUMP
> length:500mm width:400mm height:280 mm
> capacity
:
50L
1.4.1.3
W
ATER PUMP
> power = 40 W
> flow = 12L/min
> total head = 3.0m
> voltage = 220V-230V/50Hz 110V-115V/60Hz
1.4.1.4
T
HE ELECTROMAGNETIC VALVE
> voltage = 220V-230V /50Hz 110V-115V /60Hz
> power = 20 W
1.4.2
C
ONNECTION OF WATER PIPER
> the connection is as shown below
:
drainage hole
Front water of lens
Back water of lens