Chapter 2 Starting Measurement

www.supmea.com

8

Totalizer

7.digit totals for net, positive and negative flow respectively

Liquid Types

Virtually all liquids

Security

Setup values Modification Lockout. Access code needs

unlocking

Display

4x8 Chinese characters or 4x16 English letters

Communication

lnterface

RS-232C, baud.rate: from 75 to 57600. Protocol made by
the manufacturer and compatible with that of the FUJl
ultrasonic flow meter. User protocols can be made on
enquiry.

Transducers

Model M2 for standard, other 4 models for optional

Transducer Cord

Length

Standard 2 x5 meters, optional 2 x10 meters/ 2 x15 meters

Power Supply

3 AAA Ni.H built.in batteries. when fully recharged it will last

over l0 hours of operation.
1 00 V.2 4 0 VAC for the charger

Data Logger

Built. in data logger can store over 2 0 0 0 lines of data

Manual Totalizer 7-digit press-key-to-go totalizer for calibration

Housing Material ABS

Case Size

100x66x20mm

Handset weight

514g (1.2 lbs) with batteries

Chapter 2 Starting Measurement

2.1 Built.in Battery

The instrument can operate either from the built-in Ni-H rechargeable battery,
which will last over l0 hours of continuous operation when fully recharged, or from
an external AC/power supply from the battery charger.
The battery charging circuits employ a scheme of constant-current and
constant-voltage. It has a characteristic of fast charging at the beginning and very
slow charging when the battery approaches to full recharge. Generally, when the
green LED starts coming on, the battery would be nearly 95% recharged and when
the red LED is off, the battery would be 98% recharged.
since the charging current becomes tapered when the battery recharge is nearly
completed, i.e. the charging current becomes smaller and smaller, therefore, there
should be no over-recharging problem. That means the charging progress can last

Содержание SUP-2100H Series

Страница 1: ...a Automation Co Ltd www supmea com Headquarters 5th floor Building 4 Singapore Hangzhou Science Technology Park No 6 street Hangzhou Economic Development Area Hangzhou 310018 China Singapore 2 Venture...

Страница 2: ...o incorrect operation After you finish reading please keep it in a place where it can be easily accessed at any time for reference during operation Note Modification of this manual s contents will not...

Страница 3: ...mistakes If the instrument is operated in other ways not described in the manual the protections that the instrument give may be destroyed and the failures and accidents incurred due to violation of...

Страница 4: ...level shielded wires shall be located rationally SPD surge protector shall be applied properly Some inner parts may carry high voltage Do not open the square panel in the front except our company per...

Страница 5: ...fines or other objects from entering the instrument during installation otherwise it will cause abnormal movement or failure During operation to modify configuration signal output startup stop operati...

Страница 6: ...r unpredictable damage caused directly or indirectly by improper operation of the user Package contents After opening the box please confirm the package contents before starting the operation If you f...

Страница 7: ...rangement 12 2 6 Steps to Configure the Parameters 12 2 7 Transducers Mounting Allocation 14 2 8 Transducers lnstallation 16 2 8 1 Transducers spacing 16 2 8 2 V method Installation 17 2 8 3 Z method...

Страница 8: ...logger 22 3 15 How to use the frequency output function 22 3 16 How to set the cumulative pulse output 23 3 17 How to generate the output alarm signal I 23 3 18 How to use the buzzer 24 3 19 How to us...

Страница 9: ...Chapter 6 Communication Protocol 36 6 1 General 36 6 2 Interface Pin out Definition 36 6 3 The Protocol 37 6 3 Protocol Prefix Usage 38 6 4 Codes for the Keypad 39 Chapter 7 Warranty After sales Servi...

Страница 10: ...ed from the famous semiconductor manufacturers like Philips Maxim TI win bond and xilinx The hardware features the ease of operation high accuracy and outstanding reliability while the software provid...

Страница 11: ...00H transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers The transducers are clamped on the outside of a closed pipe at a specific distance from...

Страница 12: ...direction M is the travel times of the ultrasonic beam D is the pipe diameter Tup is the time for the beam from upstream transducer to the downstream one Tdown is the time for the beam from downstream...

Страница 13: ...Chapter 1 Introduction www supmea com 4...

Страница 14: ...Chapter 1 Introduction www supmea com 5...

Страница 15: ...5 Typical Applications The SUP 2100H flow meter can be virtually applied to a wide range of measurements The measured pipe ranges 20 6000 mm 0 5 200 inch A variety of liquid applications can be accom...

Страница 16: ...ase of flow accumulation It keeps operating as long as the battery s terminal voltage is over 1 5V In case of battery failure the time keeper will not keep running and it will lose proper time values...

Страница 17: ...Manual Totalizer 7 digit press key to go totalizer for calibration Housing Material ABS Case Size 100x66x20mm Handset weight 514g 1 2 lbs with batteries Chapter 2 Starting Measurement 2 1 Built in Bat...

Страница 18: ...software integrity If there is any abnormality corresponding error messages will display Generally there should be no display of error messages and the flow meter will go to the most commonly used Me...

Страница 19: ...en entering numbers Key is backspace key when the user wants go left or wants backspace the left character that is located to the left of the cursor Key is the ENTER key for any inputting or selection...

Страница 20: ...or the option selection windows the user should first press the ENT key to enter into a selection modification mode then either make the selection by pressing the and keys to select the option with a...

Страница 21: ...ter setups M 0 M 8 are windows for some additional functions including a scientific calculator viewer on records such as total working hours turn on and turn off times dates and times when the flow me...

Страница 22: ...M11 window to input the digits for the pipe outer diameter and then press key 2 Press key to enter M12 window to input the digits for the pipe outer diameter and then press key 3 Press key to enter M...

Страница 23: ...to M09 press a number key x the user will go directly to the M0x window For example if the current window displays M0l press 7 and the user will go to M07 2 when the window display is under M00 to M0...

Страница 24: ...d make sure that the pipe is completely full of liquid 2 Make sure that the temperature on the location does not exceed the range for the transducers Generally speaking the closer to the room temperat...

Страница 25: ...ucers are critical factors to the accuracy of the measurement and the performance of the system Meticulous care should be taken for the installation of the transducers steps to the installation of the...

Страница 26: ...e inner diameters ranging from 20 millimeter to 300 millimeter It is also called reflective mode or method 2 8 3 Z method Installation Z method is commonly used when the pipe diameter is between 300 m...

Страница 27: ...nal detected and 999 refers to the maximum signal strength that can be received Although the instrument works well if the signal strength ranges from 500 to 999 stronger signal strength should be purs...

Страница 28: ...ime respectively They are the primitive data for the instrument to calculate the flow rate inside the pipe so the flow rate indication will vary accordingly with the total time and delta time The tota...

Страница 29: ...nsor if the display is a negative value the direction of liquid flow from the blue sensor to the red sensor 3 3 How to change the measurement unit system Select the imperial or metric system in the M3...

Страница 30: ...lue The flowmeter treats flow rates below this value as 0 in absolute terms This parameter can be set to avoid a false accumulation of measurement errors generated by the meter when the true flow rate...

Страница 31: ...dow M52 to select the data storage direction the meter can store the data in a buffer Data can also be transferred to the RS 232C interface without being stored in a buffer Use window M53 to view the...

Страница 32: ...tor x 0 1 In window M77 select Positive cumulative pulse output 3 17 How to generate the output alarm signal I Ultrasonic flowmeter can generate two types of alarm signals audible alarm signal and swi...

Страница 33: ...ely depleted and it takes a long time to replace the battery is it necessary to change the date To change the date and time in the M61 window you can use the A key to skip the part that does not need...

Страница 34: ...ntifier containing software version and production date information Users can also use this electronic serial number for device management This electronic serial number is displayed in the M61 window...

Страница 35: ...e and time flow rate signal strength signal quality and working status M05 Display date and time velocity signal strength signal quality and working status M06 Display the wave shape of the receiving...

Страница 36: ...ryol 6 Polystyrene 7 Polyester 8 Polyethylene 9 Ebonite l0 Teflon M17 Window for entering the liner material speed only for non standard liner materials M18 Window for entering the liner thickness if...

Страница 37: ...ntry to load one set of saved parameters M28 Select YES or NO for the instrument to determine whether or not to hold or to keep the last correct value when poor signal condition occurs YES is the defa...

Страница 38: ...ible that more than 2 billions of people on the world can read the menu M40 Flow rate damper for a stable value The input range is 0 to 999 seconds 0 means there is no damping Default value is 10 seco...

Страница 39: ...ger memory 3 Buffer transferring and buffer clearing M53 Logger buffer viewer It functions as a file editor Use Dot backspace UP and DN keys to browse the buffer If the logger is ON the viewer will au...

Страница 40: ...Flow Rate value that will trigger the 1 Alarm Thereare two virtual alarms in the system By virtual we mean that the user must redirect the output of the alarms by setting up the output hardware in M7...

Страница 41: ...d pipe parameters entered and the transducer installation should be checked again M93 Displays total transit time and delta time transit time difference M94 Displays the Reynolds number and the pipe f...

Страница 42: ...ovides an automatic power on diagnosis for the hardware problems when any message with the power on in the following table displays counter measures should be taken Error message Causes Counter measur...

Страница 43: ...ter measures R System Normal No error I Detect No signal 1 No signals detected 2 Transducers installed improperly 3 Too much fouling 4 Pipe liners are too thick 5 Transducer cords are not properly con...

Страница 44: ...in for the signal and the number indicates the progressive steps K Empty pipe 1 No liquid inside pipe 2 setup error on M29 1 Relocate where the pipe is full of liquid 2 Enter 0 on M29 5 3 Other Proble...

Страница 45: ...en Please contact the factory c The battery has not been fully recharged or the recharge has been stopped too many times halfway d There is indeed a time difference between the actual working time and...

Страница 46: ...dE dd CR LF DV CR Return flow velocity d ddddddE dd CR LF DI CR Return POS totalizer dddddddE d CR LF DI CR Return NEG totalizer dddddddE d CR LF DIN CR Return NET totalizer dddddddE d CR LF DID CR Re...

Страница 47: ...cation Number in a network environment The IDN is a word ranging 0 65534 N Prefix before an Identification Number in a network environment The IDN is a single byte value ranging 00 255 P Prefix before...

Страница 48: ...en 0 and 65534 except 13 0DH 10 0AH 42 2AH 38 26H For example if the IDN 12345 instrument is addressed and returning the velocity of that instrument is requested the command will be w12345DV CR 3 Pref...

Страница 49: ...h the keypad code By this function remote operation of this instrument can be realized even via the Internet Key Hexadecima1 Key code Decimal Key code ASCII Code 0 30H 48 0 1 31H 49 1 2 32H 50 2 3 33H...

Страница 50: ...e and all non customized products are guaranteed to be returned and replaced within 7 days Disclaimers During the warranty period product faults caused by the following reasons are not in the scope of...

Отзывы: