Chapter 4 Configuration description
42
Configuration item descriptions:
Configuration
item
Function descriptions
File format
Save
instrument
configuration
Save current instrument configuration
CFG
(
.cfg
)
Read
instrument
configuration
Read instrument configuration in USB disk.
Note: instrument configuration is scanned
when USB disk inserted. The newly saved
configuration will only be displayed after
re-inserting USB disk.
4.2.3 Reset operation
Configuration item descriptions:
Configuration item
Function descriptions
Clear log record
Clear all log record
Clear power-off record
Clear all power-off record
Clear alarm information
Clear all alarm information
4.3 System setting
Configuration item descriptions:
Configuration
item
Function
descriptions
Parameters range
password
Set password
000000~999999
instrument name
Set instrument name
8 bit character string
system time
Set system time
time format
Set time format
YY-MM-DD
,
DD-MM-YY
,
MM-DD-YY
record interval
Set record interval
1s, 2s, 5s, 10s, 15s, 30s, 1min, 2min,
5min, 10min, 30min, 60min (one second
can be recorded for 10 days).
Curvilinear Coor
dinates
Set
Curvilinear Coordina
tes
Hundred components and quantities
language
Select
system
language
Chinese/English
Start up page
Set start up page in
default
Overview, digital display, history
Содержание 6000f
Страница 9: ......
Страница 17: ...Chapter 2 Installation and wiring 8 Fig 2 3 Terminal view...
Страница 29: ...Chapter 3 Basic operation method 20 History 3 2 times...
Страница 38: ...Chapter 3 Basic operation method 29 3 Select enter and press enter key Note select cancel as default...