![Superrollo GW180 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/superrollo/gw180/gw180_operating-and-assembly-manual_1405809035.webp)
35
EN
19. Removing the belt in the event of unit failure
In the event that the superrollo GW180 / GW185 unit fails
and the motor no longer runs, you can use the disengag-
ing bracket provided in order to fully remove the belt
from the belt winder unit, without the need for cutting it.
WARNING!
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆
Secure the roller shutters from falling, for example,
by laying something underneath it.
◆
Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆
Get a second person to help you unlatch the unit.
i
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the superrollo GW180 / GW185 as far as
possible.
1.
Remove the mains plug from the
socket.
2.
Turn the superrollo GW180 / GW185
completely to the side.
3.
Release the drive with the help of the supplied disen-
gaging bracket. A small amount of resistance must be
overcome when pressing.
5.
Remove the reel compartment cover. Release the belt
from the fastening hook and pull it out completely
from the superrollo GW180 / GW185.
6.
Press the assembly locking device on the back part
and remove the superrollo GW180 / GW185 from the
wall bracket by pulling it downwards.
7.
Place the disengaging bracket back into the storage
compartment.
Drive release
Storage bay
Содержание GW180