background image

iii

Preface

Preface

This manual is written for system integrators, IT professionals, and  
knowledgeable  end users. It provides information for the installation and use of the 

 X10SRL-F motherboard. 

About This Motherboard

The 

 X10SRL-F supports a single Intel

®

 E5-2600/1600 Series processor in 

an LGA2011 R3 socket. With the Intel

®

 C612 Express chipset built in, the X10SRL-

F motherboard supports Intel

®

 Server Platform Services (Intel SPS), offering great 

system enhancement to high performance storage platforms. Please refer to our 
website (http://www.supermicro.com/products/) for processor and memory support 
updates. This product is intended to be installed and serviced by professional 
technicians.

Manual Organization

Chapter 1

 describes the features, specifications and performance of the mother

-

board, and provides detailed information on the Intel

®

 C612 Express chipset. 

Chapter 2

 provides hardware installation instructions. Read this chapter when in-

stalling the processor, memory modules and other hardware components into the 
system. If you encounter any problems, see 

Chapter 3

, which describes trouble-

shooting procedures for video, memory and system setup stored in the CMOS. 

Chapter 4

 includes an introduction to the BIOS, and provides detailed information 

on running the CMOS Setup utility.

Appendix A 

provides BIOS Error Beep Codes. 

Appendix B 

lists software program installation instructions

Appendix C 

contains UEFI BIOS Recovery instructions. 

Appendix D 

contains Dual Boot Block instructions.

Содержание X10SRL-F

Страница 1: ...X10SRL F USER S MANUAL Revision 1 1a...

Страница 2: ...its for a class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipme...

Страница 3: ...ed and serviced by professional technicians Manual Organization Chapter 1 describes the features specifications and performance of the mother board and provides detailed information on the Intel C612...

Страница 4: ...should be given to the following symbols for proper system instal lation Warning Critical information given to prevent damage to the components or injury to yourself Note Additional Information provi...

Страница 5: ...dress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl T...

Страница 6: ...1 5 ACPI Features 1 11 Slow Blinking LED for Suspend State Indicator 1 11 1 6 Power Supply 1 11 Chapter 2 Installation 2 1 Standardized Warning Statements 2 1 Battery Handling 2 1 Product Disposal 2 3...

Страница 7: ...PWR Fail UID LED 2 24 Power Fail LED 2 24 Reset Button 2 25 Power Button 2 25 2 7 Connecting Cables 2 26 ATX Main PWR CPU PWR Connectors J24 JPWR1 2 26 Fan Headers Fan 1 Fan 5 Fan A 2 27 Chassis Intr...

Страница 8: ...ions 3 4 3 4 Battery Removal and Installation 3 5 Battery Removal 3 5 Proper Battery Disposal 3 5 Battery Installation 3 5 3 5 Returning Merchandise for Service 3 6 Chapter 4 BIOS 4 1 Introduction 4 1...

Страница 9: ...pectrum 4 6 Hyper Threading ALL 4 6 Cores Enabled 4 6 Execute Disable Bit Available if supported by the OS the CPU 4 7 PPIN Control 4 7 Hardware Prefetcher Available when supported by the CPU 4 7 Adja...

Страница 10: ...ms will display 4 19 Server ME Management Engine Configuration 4 20 PCIe PCI PnP Configuration 4 20 The following PCI information will be displayed 4 20 PCI PERR SERR Support 4 21 Above 4G Decoding Av...

Страница 11: ...ices Console Redirection 4 27 EMS Console Redirection Settings 4 27 ACPI Settings 4 28 WHEA Support 4 28 High Precision Timer 4 28 PCI AER Advanced Error Reporting Support 4 28 4 4 Event Logs 4 29 Cha...

Страница 12: ...t 4 35 Setup Prompt Timeout 4 35 Boot Mode Select 4 35 Fixed Boot Order Priorities 4 35 Delete Boot Option 4 36 Network Drive BBS Priorities 4 36 UEFI Application Boot Priorities 4 36 4 8 Save Exit 4...

Страница 13: ...BIOS Image C 1 C 3 To Recover the Main BIOS Block Using a USB Attached Device C 1 Appendix D Dual Boot Block on Grantley Platforms Overview D 1 Before Startup D 1 When to Use Dual Boot Block D 1 How t...

Страница 14: ...xiv Notes X10SRL F User s Manual...

Страница 15: ...otherboard If anything listed here is damaged or missing contact your retailer The following items are included in the retail box One 1 Supermicro Motherboard Six 6 SATA cables One 1 I O shield One 1...

Страница 16: ...ard Image Note All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual Your motherboard or components may or may not look exactly th...

Страница 17: ...TPM1 JF1 JD1 T SGPIO1 T SGPIO2 T SGPIO3 JOH1 JL1 JPME2 JWD1 JPG1 JPB1 JI2C2 JI2C1 JBR1 JPL2 JPL1 JVR1 JSD1 JSD2 JIPMB1 JPWR1 UID LED LE1 LE2 LEDM1 JBT1 BT1 FAN4 FAN1 FAN2 FAN3 FANA FAN5 J24 JPI2C1 JST...

Страница 18: ...N CTRL LAN CTRL BMC JP3 JTPM1 JF1 JD1 T SGPIO1 T SGPIO2 T SGPIO3 JOH1 JL1 JPME2 JWD1 JPG1 JPB1 JI2C2 JI2C1 JBR1 JPL2 JPL1 JVR1 JSD1 JSD2 JIPMB1 JPWR1 UID LED LE1 LE2 LEDM1 JBT1 BT1 FAN4 FAN1 FAN2 FAN3...

Страница 19: ...WM SMB Programming for debugging only LAN1 LAN2 Gigabit RJ45 Ports LAN1 2 IPMI_LAN IPMI_Dedicated LAN I SATA 0 9 Intel PCH Serial ATA SATA 3 0 Ports 0 9 6Gb sec PCH Slot 1 PCI Express 2 0 x4 in x8 Slo...

Страница 20: ...s with Link and Activity LEDs I O Devices SATA Connections SATA 3 0 6Gb s Ten 10 SATA3 ports AHCI controller supports six 6 SATA3 drives compatible with RAID 0 1 5 10 sSATA controller supports four 4...

Страница 21: ...5V 12V 3 3V Stdby VBAT Memory PCH and BMC voltage CPU 5 phase switching voltage CPU System overheat LED and control CPU Thermal Trip support Thermal Monitor support Fan Control Fan status monitoring w...

Страница 22: ...CG 3 2 RJ45 BIOS SPI SPI Temp Sensor EMC1402 1 2 at diff SMBUS TPM HEADER USB 3 0 USB3 0 BIOS HEADER SPI AST2400 BMC 6 7 RMII NCSI COM1 Connector COM2 Header VGA CONN BMC Boot Flash DDR3 1 0 5 4 3 2...

Страница 23: ...gh speed Direct Media Interface DMI for chip to chip true isochronous communication providing up to 5 GT s of software transparent data transfer rate on each read write direction In addition the X10SR...

Страница 24: ...can adjust the voltage thresholds to define the sensitivity of the voltage monitor Environmental Temperature Control The thermal control sensor monitors the CPU temperature in real time and will turn...

Страница 25: ...ically stop blinking and remain on 1 6 Power Supply As with all computer products a stable power source is necessary for proper and reliable operation It is even more important for processors that hav...

Страница 26: ...1 12 X10SRL F User s Manual Notes...

Страница 27: ...omponents Read this section in its entirety before installing or configuring components in the Supermicro chassis Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefah...

Страница 28: ...n si la bater a se reemplaza de manera incorrecta Re emplazar la bater a exclusivamente con el mismo tipo o el equivalente recomen dado por el fabricante Desechar las bater as gastadas seg n las inst...

Страница 29: ...dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y regla mentos nacionales Attention L...

Страница 30: ...ntacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chass...

Страница 31: ...X8 IN X16 Intel PCH 1 1 Location of Mounting Holes Caution 1 To avoid damaging the motherboard and its components please do not use a force greater than 8 lb inch on each mounting screw during mother...

Страница 32: ...fs in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 6 Using the Phillips screwdriver insert a Phillips head 6 screw into a m...

Страница 33: ...n Intel certified multi directional heatsink only Make sure to install the system board into the chassis before you install the CPU heatsink When receiving a server board without a processor pre insta...

Страница 34: ...om its locking position 3 With the lever labeled Close 1st fully retracted gently push down on the lever labelled Open 1st to open the load plate Lift the load plate to open it completely OPEN1st WARN...

Страница 35: ...ket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket So...

Страница 36: ...ose the load plate with the CPU inside the socket Lock the lever labelled Close 1st first then lock the lever labelled Open 1st second Using your thumb gently push the load levers down to the lever lo...

Страница 37: ...board s and the Heatsink Bracket under neath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws to avoid possible damage to the CPU 4 Finish the i...

Страница 38: ...rboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the heatsink is loosened...

Страница 39: ...recommended memory mod ules CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Installing Memory Modules 1 Insert the desired number of DIMMs into t...

Страница 40: ...same type and size will result in interleaved memory which will improve memory performance Please refer to the table on the next page Memory Population Guidelines When installing memory modules the D...

Страница 41: ...2 DDR4 2133 1866 1600 Empty Dual rank 3 DDR4 1866 1600 Single rank Single rank 4 DDR4 1866 1600 Single rank Dual rank 5 DDR4 1866 1600 Dual rank Dual rank Populating LRDIMM Memory Modules 2 Slots per...

Страница 42: ...availability is disproportional See the following table for details Possible System Memory Allocation Availability System Device Size Physical Memory Remaining Available 4 GB Total System Memory Firmw...

Страница 43: ...L BMC JP3 JTPM1 JF1 JD1 T SGPIO1 T SGPIO2 T SGPIO3 JOH1 JL1 JPME2 JWD1 JPG1 JPB1 JI2C2 JI2C1 JBR1 JPL2 JPL1 JVR1 JSD1 JSD2 JIPMB1 JPWR1 UID LED LE1 LE2 LEDM1 JBT1 BT1 FAN4 FAN1 FAN2 FAN3 FANA FAN5 J24...

Страница 44: ...IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 A Backpanel USB 2 0 0 1 B Backpanel USB 3 0 2 3 C Fron...

Страница 45: ...DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 Ethernet Ports Two Gigabit Ethernet ports LAN1 LAN2 and an IPMI_LAN port are located on the I O Backpanel to provide ne...

Страница 46: ...X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 A VGA B UID Switch C UID LED A B C Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and an LED Indicator are located on the motherb...

Страница 47: ...PCI E 2 0 X4 IN X8 COM2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1...

Страница 48: ...M2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 Power Button OH Fa...

Страница 49: ...CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 Power Button OH Fan Fail LED 1 NIC1 LED Reset Button 2 HDD LED Power LED Reset PWR P3V3 P3V3_STB P3V3_STB P5V_STB Ground Ground 19 20 P3V3 X Ground NMI X P3...

Страница 50: ...CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 Power Button OH Fan Fail LED 1 NIC1 LED Reset Button 2 HDD LED Power LED Reset PWR P3V3 P3V3_STB P3V3_STB P5V_STB Ground Ground 19 20 P3V3 X Ground NMI X P3...

Страница 51: ...IN X8 PCH SLOT1 PCI E 2 0 X4 IN X8 COM2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 I...

Страница 52: ...N X16 Intel PCH 1 1 2 7 Connecting Cables This section provides brief descriptions and pin out definitions for onboard headers and connectors Be sure to use the correct cable for each header or connec...

Страница 53: ...PU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 Fan Header Pin Definitions Pin Definition 1 Ground Black 2 2 5A 12V Red 3 Tachometer 4 PWM_Control Fan Headers Fan 1 Fan 5 Fan A The X10SRL F has six fan hea...

Страница 54: ...CI E 3 0 X4 IN X8 PCH SLOT1 PCI E 2 0 X4 IN X8 COM2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI...

Страница 55: ...SLOT2 PCI E 3 0 X4 IN X8 PCH SLOT1 PCI E 2 0 X4 IN X8 COM2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SL...

Страница 56: ...IMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 A T SGPIO 1 B T SGPIO 2 C T SGPIO...

Страница 57: ...CI E 3 0 X8 IN X16 Intel PCH 1 1 Video Connector A Video VGA connector is located next to the COM Port on the I O backpanel This connector is used to provide video and CRT display Refer to the board l...

Страница 58: ...IMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 2 8 Jumper Settings Explanation of Jumper...

Страница 59: ...B1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 CMOS Clear JBT1 is used to clear the...

Страница 60: ...OM2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 A JPME2 B VGA Ena...

Страница 61: ...5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 Watch Dog Enable Disable Watch Dog JWD1 is a system moni tor that can...

Страница 62: ...X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 A BMC Enable Disable A BMC Enable Disable JPB1 JPB1 is used to enable or disable the BMC Baseboard Management Control chip and the onboard IPMI connecti...

Страница 63: ...LAN 2 are located on the I O backplane of the motherboard Each Ethernet LAN port has two LEDs The yellow LED indicates activity while the Link LED may be green amber or off to indicate the speed of t...

Страница 64: ...E 2 0 X4 IN X8 COM2 COM1 DIMMB2 DIMMB1 DIMMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1...

Страница 65: ...MMD2 DIMMD1 IPMI_LAN UID SW 5V STBY USB11 3 0 IPMI VGA CPU SLOT7 PCI E 3 0 X8 DIMMC1 CPU SLOT3 PCI E 3 0 X4 IN X8 CPU SLOT6 PCI E 3 0 X8 IN X16 Intel PCH 1 1 2 10 SATA Connections SATA Connections Ten...

Страница 66: ...2 40 X10SRL F User s Manual Notes...

Страница 67: ...ents 2 Make sure that there are no short circuits between the motherboard and chassis 3 Disconnect all ribbon wire cables from the motherboard including those for the keyboard and mouse Also be sure t...

Страница 68: ...mmended that you use the memory modules of the same type and speed for all DIMMs in the system Do not use memory modules of different sizes different speeds and different types on the same motherboard...

Страница 69: ...be downloaded from our website at http www supermi cro com support bios Note Not all BIOS can be flashed Some cannot be flashed it depends on the boot block code of the BIOS 3 If you ve followed the i...

Страница 70: ...drive Use the following format F flash bat BIOS ROM filename xxx Enter Note Always use the file named flash bat to update the BIOS and insert a space between flash bat and the filename The BIOS ROM f...

Страница 71: ...damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulatio...

Страница 72: ...permicro com RmaForm When you return the motherboard to the manufacturer the RMA number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shippin...

Страница 73: ...t can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text me...

Страница 74: ...rade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special incident...

Страница 75: ...M DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10SRL F BIOS Version This item displays the version...

Страница 76: ...this feature to select the screen between displaying POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select En abled to display the OEM logo instead of the normal...

Страница 77: ...o allow the BIOS to automatically reboot the system from a Legacy boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function Se...

Страница 78: ...he RAM CPU1 Version Clock Spread Spectrum Select Enable for Clock Spectrum support which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the co...

Страница 79: ...ne Prefetch Available when supported by the CPU Select Enable for the CPU to prefetch both cache lines for 128 bytes as comprised Select Disable for the CPU to prefetch both cache lines for 64 bytes T...

Страница 80: ...y protected I O resource sharing across the Intel platforms providing the user with greater reliability security and availability in networking and data sharing The settings are Enable and Disable Adv...

Страница 81: ...ing system During the CPU C3 State the CPU clock generator is turned off The options are Enable and Disable CPU C6 Report Available when Power Technology is set to Custom Select Enable to allow the BI...

Страница 82: ...ied by the user The options are Gen 1 2 5GT s Gen 2 5 GT s and Gen 3 8GT s CPU SLOT5 PCI E 3 0 X8 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The opt...

Страница 83: ...tor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing...

Страница 84: ...ed and Disabled Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules The options are Auto 1333 1400 1600 1800 1867 2000 2133 2200 2400 2600 2667 and Reserve...

Страница 85: ...mory RAS Reliability Availability Serviceability Configuration Use this submenu to configure the following Memory RAS settings RAS Mode Select Enable to enable RAS support to enhance reliability avail...

Страница 86: ...item to specify the number of hours between 0 to 24 required for the system to complete a full patrol scrubbing Enter 0 for patrol scrubbing to be performed automatically The default setting is 24 De...

Страница 87: ...Enhanced Host Controller Interface EHCI hand off When this item is enabled EHCI ownership change will be claimed by the EHCI driver The settings are Enabled and Disabled Port 60 64 Emulation Select E...

Страница 88: ...e specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are IDE AHCI and RAID If the item above Configure SATA as is set to AHC...

Страница 89: ...e user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure SATA as is set to RAID the following items wil...

Страница 90: ...A controller supported by the Intel SCU chip The options are Enabled and Disabled Configure sSATA as Select IDE to configure an sSATA drive specified by the user as an IDE drive Select AHCI to configu...

Страница 91: ...le when a SATA port is detected Use this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and So...

Страница 92: ...se this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive Server ME Managem...

Страница 93: ...PCI E device to enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes ASPM Support Use this item to set the Active State Power Management A...

Страница 94: ...phics device to be used as the primary video display at bootup The options are Onboard and Offboard Network Stack Select Enabled to enable PXE Preboot Execution Environment or UEFI Unified Extensible...

Страница 95: ...led and Disabled If the item above set to Enabled the following items will become available for configuration COM1 Console Redirection Settings Terminal Type This feature allows the user to select the...

Страница 96: ...e Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buff...

Страница 97: ...with the client computer which is the remote computer used by the user Terminal Type Use this feature to select the target terminal emulation type for Console Redirec tion Select VT100 to use the ASCI...

Страница 98: ...e Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buff...

Страница 99: ...eature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Management Port The feature selects a seri...

Страница 100: ...hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring The options are Enabled and Disabled High Precision Timer Select Enable...

Страница 101: ...Error Logging The options are Enable and Dis able If this item is set to Enable the following item will be available for configuration Memory Corrected Error Enabling Available when the item above Ru...

Страница 102: ...em Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number...

Страница 103: ...ed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Selec...

Страница 104: ...Address Source Use this item to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually i...

Страница 105: ...Chapter 4 AMI BIOS 4 33 Gateway IP Address This item displays the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253...

Страница 106: ...to check for a password at Setup Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Use this...

Страница 107: ...BIOS to wait indefinitely The default setting is 1 Boot Mode Select Use this item to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual The default se...

Страница 108: ...ot device to delete from the boot priority list Delete Boot Option Select the target boot device to delete Network Drive BBS Priorities Boot Order 1 This feature sets the system boot order of detected...

Страница 109: ...es and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion parameters can take e...

Страница 110: ...ts from the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit m...

Страница 111: ...rror oc curs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list cor...

Страница 112: ...A 2 X10SRL F User s Manual Notes...

Страница 113: ...you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown below should appear Note 1 Clic...

Страница 114: ...and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Man agement Server SSM Server you can remotely control power on off and reset ch...

Страница 115: ...otup C 2 How to Recover the UEFI BIOS Image A UEF BIOS flash chip consists of a recovery BIOS block comprised of two boot blocks and a main BIOS block a main BIOS image The boot block contains critica...

Страница 116: ...ur driver disk visit our website at www supermicro com to download the BIOS image into a USB flash device and rename it Super ROM for BIOS recovery use 2 Insert the USB device that contains the new BI...

Страница 117: ...ry is complete press any key to reboot the system 7 Using a different system extract the BIOS package into a bootable USB flash drive 8 When a DOS prompt appears enter FLASH BAT BIOSname at the prompt...

Страница 118: ...from the power supply to clear CMOS and then plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load def...

Страница 119: ...rtup A USB flash drive with FAT32 file system and Super ROM stored are required and the USB flash drive does not need to be bootable IPMI firmware that is capable of supporting BIOS Resilience functio...

Страница 120: ...gh the IPMI GUI browser follow the instructions below 1 After the IPMI GUI browser log in click on the Miscellaneous tab then BIOS Resilience then the Resile button 2 IPMI prints out a message that in...

Страница 121: ...3 Click on the Remote Control tab then Console Redirection then the Launch Console button to open the Java iKVM Viewer 4 In the Java iKVM Browser click on the Virtual Media tab then Virtual Stor age t...

Страница 122: ...Device1 tab then Logical Drive Type drop down menu then select the USB flash drive with Super ROM Click Plug In then OK 6 Click on the Remote Control tab then Power Control then check the Power On Se...

Страница 123: ...h drive which was mounted earlier If Super ROM is found the on duty boot block boots to it and finishes the rest of the POST processes The system will automatically enter the BIOS recovery flash page...

Страница 124: ...Manual 9 A message box will appear to indicate the BIOS recovery flash process is complete Press ENTER to finish The system will do a power cycle to deacti vate the dual boot block feature and produce...

Страница 125: ...PMI Command Sets follow the instructions below 1 After the IPMI GUI browser log in click on the Remote Control tab then Console Redirection then the Launch Console button to open Java iKVM Viewer 2 Op...

Страница 126: ...mmand prompt impi raw 30 70 C3 D5 4 Mount the USB flash drive with Super ROM to remote Virtual Media Device 1 This must de done in the IPMI Shell mode To enter the IPMI Shell mode type shell To see th...

Страница 127: ...the USB flash drive which are the same as Steps 7 9 in Section D 1 User Approach Dual Boot Block is not designed for an automatic operation non user attended op eration The feature offers an immediate...

Страница 128: ...D 10 X10SRL F User s Manual Notes...

Страница 129: ...expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in su...

Отзывы: