background image

1-2

SUPERSERVER 7046GT-TRF Series User's Manual

One (1) Supermicro CD containing drivers and utilities

• 

1-2 Serverboard 

Features

At the heart of the SuperServer 7046GT-TRF series lies the X8DTG-QF, a dual 

processor serverboard based on the Intel 5520 (IOH-36D) chipset. Below are 

the main features of the X8DTG-QF. (See Figure 1-1 for a block diagram of the 

chipset).

Processors

The X8DTG-QF supports two Intel

®

 5500 series (LGA 1366) processors supporting 

two full-width Intel QuickPath Interconnect (QPI) links with a total of up to 51.2 

GT/s Data Transfer Rate (6.4 GT/s per direction). Please refer to the serverboard 

description pages on our web site for a complete listing of supported processors 

(www.supermicro.com).

Memory

The X8DTG-QF has twelve 240-pin DIMM slots that can support up to 192 GB of 

registered ECC DDR3-1333/1066/800 SDRAM or up to 48 GB of unbuffered ECC/

non-ECC DDR3-1333/1066/800 MHz SDRAM. Modules of the same size and speed 

are recommended (for Unbuffered ECC/Non-ECC memory, a maximum of 2 GB per 

DIMM is supported). See Chapter 5 for details.

Serial ATA 

A SATA controller is integrated into the South Bridge (ICHR10R) section of the 

chipset to provide a six-port 3/Gbs SATA subsystem, which is RAID 0, 1, 5 and 

10 supported (RAID0, RAID1, RAID10, RAID5 supported in the Windows OS 

Environment and RAID 0, RAID 1, RAID 10 supported by the Linux OS). The SATA 

drives are hot-swappable units.

Note:

 The operating system you use must have RAID support to enable the hot-

swap capability and RAID function of the Serial ATA drives.

PCI Expansion Slots

The X8DTG-QF has four PCI-E Gen. 2.0 x16 slots (Slot 4, Slot 6, Slot 8, Slot 10), 

one PCI-E Gen. 2.0 x4 (in x16) slot (Slot 2), one PCI-E 2.0 x4 (in x8) slot (Slot 11), 

one PCI-E Gen. 1.0 x4 (in x16) slot (Slot 1) and two PCI 33 MHz slots (Slot 3, Slot 

5) for a total of nine (9) PCI expansion slots.

Содержание SUPERSERVER 7046GT-TRF

Страница 1: ...SUPERSERVER 7046GT TRF 7046GT TRF TC4 7046GT TRF FC405 7046GT TRF FC407 SUPER USER S MANUAL Revision 1 0d...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...TRF TC4 4x Nvidia Tesla C1060 GPU Cards 7046GT TRF FC405 4x Nvidia Fermi C2050 GPU Cards 7046GT TRF FC407 4x Nvidia Fermi C2070 GPU Cards Manual Organization Chapter 1 Introduction The first chapter p...

Страница 4: ...er when adding or removing processors or main memory and when reconfiguring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC747TQ R1400B 4U Tower...

Страница 5: ...v Preface Notes...

Страница 6: ...4 1 4 GPU Subsystem 7046GT TRF series Only 1 4 1 5 Contacting Supermicro 1 6 Chapter 2 System Setup 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Setting Up the System 2 2 Checking the Motherboard...

Страница 7: ...bles 5 3 Connecting Data Cables 5 3 Connecting Power Cables 5 3 Connecting the Control Panel 5 3 5 4 I O Ports 5 5 5 5 Installing the Processor and Heatsink 5 6 Installing an LGA1366 Processor 5 6 Ins...

Страница 8: ...a Drive Carrier 6 10 Adding Peripheral Drives 6 12 6 6 Installing Hard Drives in the Chassis 6 13 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Configuration D...

Страница 9: ...r Beep Codes A 1 BIOS Error Beep Codes A 1 Appendix B Installing Windows B 1 Installing Windows for a RAID System B 1 B 2 Installing Windows for a Non RAID System B 2 Appendix C System Specifications...

Страница 10: ...x SUPERSERVER 7046GT TRF Series User s Manual Notes...

Страница 11: ...4U active CPU heatsinks SNK P0035AP4 SATA accessories I O shield MCP 260 00025 0N One HD backplane BPN SAS 747TQ Six 35 cm SATA cables CBL 0061L Two 40 cm PBF 8 pin to 8 pin ribbon cable with tube for...

Страница 12: ...R3 1333 1066 800 SDRAM or up to 48 GB of unbuffered ECC non ECC DDR3 1333 1066 800 MHz SDRAM Modules of the same size and speed are recommended for Unbuffered ECC Non ECC memory a maximum of 2 GB per...

Страница 13: ...tage regulators a chassis intrusion header keyboard wakeup from soft off console redirection chassis and CPU overheat sensors fan status monitor with firmware control Pulse Width Modulation PWM Fan Co...

Страница 14: ...rs Backplane Each SC747 chassis comes with a 4U backplane Depending on your order your backplane will accept SAS SATA For more information regarding compatible backplanes view the appendices found at...

Страница 15: ...5 6 REAR 2 Internal 2 Type A 6 FRONT LAN1 LAN2 SPI WPCM450 BIOS Ports 1 2 HD ALC888 AUDIO CONN COM1 VGA1 CSI1 CSI1 CSI0 CSI0 PCI E x16 PCI E x16 6 7 8 9 TPM Keyboard LAN Ports 3 4 5 6 Port6 PCI E x4...

Страница 16: ...ope Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicr...

Страница 17: ...way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for setting up and operating the SuperServer 7046GT TRF series serv...

Страница 18: ...nk attached See Chapter 5 for instructions on processor installation Check the system memory 3 Your system may have come with system memory already installed Make sure all DIMMs are fully seated in th...

Страница 19: ...r to the system Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and power surges It is recommended that you use an uninterru...

Страница 20: ...e unstable General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine the placement of each component in th...

Страница 21: ...omised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the...

Страница 22: ...e will differ slightly You should also refer to the installation instructions that came with the rack unit you are using NOTE The outer rail is adjustable from 26 to 38 25 NOTE The MCP 290 00059 0N ra...

Страница 23: ...s a tab located in the center of the foot that prevents the foot 3 from sliding Using a flat head screwdriver gently lift the foot lock upward and slide the foot toward the rear of the chassis Repeat...

Страница 24: ...n the chassis handle with the front of the chassis and secure with the 2 three chassis handle screws Repeats steps 1 and 2 with the other handle 3 Locate the inner rails and screws in the shipping pac...

Страница 25: ...s to the proper distance so that the rail fits snugly into the rack 3 Secure the rear of the outer rail with two M5 screws and the rear of the rack NOTE The outer rail is adjustable from approximately...

Страница 26: ...s the inner rails and the outer rails 2 Align the inner chassis rails with the front of the outer rack rails C 3 Slide the inner rails into the outer rails keeping the pressure even on both sides you...

Страница 27: ...d to return the chassis to tower mounting Installing the Chassis Cover Installing the Cover Remove the rack mount ears 1 Align the cover post with the corresponding holes on the top of the chassis 2 a...

Страница 28: ...ot in the foot receptacle and slide the foot toward the 1 front of the chassis The foot should lock into place Secure the foot to the chassis using one screw enclosed in the packaging 2 Repeat steps 1...

Страница 29: ...to keep you constantly informed of the overall status of the system as well as the activity and health of specific components Most SC747 models are two buttons on the chassis a control panel a reset b...

Страница 30: ...upplied to the system Therefore you must unplug system before servicing Reset The reset button is used to reboot the system 3 3 Control Panel LEDs The control panel located on the front of the SC747 c...

Страница 31: ...bstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to m...

Страница 32: ...ve carrier has a green LED When illuminated this green LED on the front of the SATA drive carrier indicates drive activity A con nection to the SATA backplane enables this LED to blink on and off when...

Страница 33: ...wer down the operating system first and then unplug the power cords The unit has more than one power supply cord Disconnect two power supply cords before servicing to avoid electrical shock When worki...

Страница 34: ...etting PTC Positive Tempera ture Coefficient fuses on the mainboard must be replaced by trained service technicians only The new fuse must be the same or equivalent as the one replaced Contact technic...

Страница 35: ...ing measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Use a grounded wrist strap designed to prevent static discharge Keep all c...

Страница 36: ...practice is not strictly followed Figure 4 1 Installing the Onboard CR2032 Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the CR2032 bat tery in any way a...

Страница 37: ...o handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally s...

Страница 38: ...h when installing a screw into a mounting hole I O Slot Shield Installation The I O shield holds the motherboard ports in place Install the I O shield before you install the motherboard Installing the...

Страница 39: ...locations SATA drive data cables SATA0 SATA5 SGPIO cable T SGP101 TSGPIO2 Control Panel cable JF1 Important Make sure the the cables do not come into contact with the fans Connecting Power Cables The...

Страница 40: ...ER 7046GT TRF Series User s Manual Figure 5 4 Control Panel Header Pins NMI x key Vcc Vcc Vcc Vcc Vcc Vcc Reset Power Ground x key Power LED HDD LED NIC1 NIC2 OH Fan Fail LED Power Fail LED Ground Gro...

Страница 41: ...M Port 1 Turquoise 4 VGA Blue 5 USB 0 6 USB1 7 IPMI_Dedicated LAN 8 USB 2 9 USB 3 10 USB 4 11 USB 5 12 LAN 2 13 LAN 1 14 Side_surround 15 Back_surround 16 CEN LFE 17 Microphone_In 18 Front 19 Line_In...

Страница 42: ...nto the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins ar...

Страница 43: ...ocket or its pins to avoid damaging the CPU or the socket With the CPU in the socket inspect the 7 four corners of the CPU to make sure that it sits level and is properly installed Once the CPU is sec...

Страница 44: ...ng the CPU or the heatsink However if you do need to uninstall the heatsink please follow these instructions to avoid damaging the CPU or the CPU socket Installation and Removal of the Heatsink Uninst...

Страница 45: ...lots as indicated on the tables below Insert each DIMM module vertically into its slot Pay attention to the notch 2 along the bottom of the module to avoid installing incorrectly see Figure 5 6 Gently...

Страница 46: ...MM2A P2 DIMM3A 6 DIMMs P2 DIMM1A P2 DIMM1B P2 DIMM2A P2 DIMM2B P2 DIMM3A P2 DIMM3B Memory Population for Optimal Performance For a motherboard with Two CPUs installed CPU1 CPU2 Branch 0 Branch 1 Branc...

Страница 47: ...R 2 1 Reg DDR3 ECC 800 1066 Note 1 QR 2 2 Reg DDR3 ECC 800 1066 Note 1 Mixing SR DR 2 2 Reg DDR3 ECC 800 Note 2 Mixing SR DR QR Note 1 1333 RDIMMs will run at 1066 Mhz BIOS automatic downgrading Note...

Страница 48: ...Registered Speeds in MHz Ranks per DIMM any combination SR Single Rank DR Dual Rank QR Quad Rank 2 1 Unbuffered DDR3 ECC Non ECC 800 1066 1333 SR or DR 2 2 Unbuffered DDR3 ECC Non ECC 800 1066 1333 Mi...

Страница 49: ...ms may not show more than 4 GB of memory Note 2 Due to memory allocation to system devices the amount of mem ory that remains available for operational use will be reduced when 4 GB of RAM is used The...

Страница 50: ...card Slot 2 one PCI E 2 0 x4 in x8 card Slot 11 one PCI E Gen 1 0 x4 in x16 card Slot 1 and two PCI 33 MHz cards Slot 3 Slot 5 for a total of nine 9 PCI expansion cards The SuperServer 7046GT TRF seri...

Страница 51: ...PCI card or other add on card into the PCI slot bracket and 5 motherboard To do this slide the PCI card with L bracket into the PCI slot and secure the card to the motherboard Push the PCI bracket rel...

Страница 52: ...number bracket is recommended for this application and may be purchased by visiting the Supermicro Web site at http www supermicro com and clicking on the Where to Buy link Installing Double Width Gra...

Страница 53: ...card bracket into the slots on the 3 wall of the chassis as illustrated in Figure 5 10 Lower the bracket down onto the card 4 Pull back the slide lock and lower it over the raised tab as illustrated...

Страница 54: ...etails Notes Jumpers not indicated are for test purposes only For more information on 1 jumpers or components refer to Chapter 2 indicates the location of Pin 1 2 When DP1 LED is on the onboard power...

Страница 55: ...COM1 COM2 Serial Connections FAN 1 10 System CPU Fan Headers Fans 7 8 CPU Fans I SATA0 5 Intel South Bridge SATA Ports 0 5 JD1 PWR LED Pins 1 3 Speaker Pins 4 7 JF1 Front Panel Connector JL1 Chassis...

Страница 56: ...JPW1 and the two 8 pin JPW2 JPW3 power connectors on the motherboard Failure in do ing so will void the manufacturer warranty on your power supply and motherboard 24 pin Main Power Connector Pin Defin...

Страница 57: ...ailure or power failure The blue LED pin 7 works as the UID LED indicator for the front panel UID button located on pins 13 14 of JF1 When Jumper J_UID_OW is set to off default the red LED takes prece...

Страница 58: ...located on pins 13 14 of JF1 Attach a hard drive LED cable to display HDD or SATA activity This connection can also be used for the front panel UID Unit Identifier button The UID LED on pin 7 of JF1...

Страница 59: ...ed JL1 Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground Universa...

Страница 60: ...3 88 Ground NC No Connection Serial Ports Two COM connections COM1 COM2 are located on the motherboard COM1 is located on the Backplane IO panel COM2 is header located next to PCI E Slot 1 to provide...

Страница 61: ...h your motherboard to use this feature CD 10 pin Audio Headers A 4 pin CD header CD1 and a 10 pin Front Panel Audio header J138 are also located on the motherboard These headers allow you to use the o...

Страница 62: ...peaker please close pins 6 7 with a jumper See the tables on the right for pin definitions Speaker Connector Pin Definitions Pin Setting Definition Pins 4 7 External Speaker Pins 6 7 Internal Speaker...

Страница 63: ...ng Fan Fail Wake On LAN Pin Definitions Pin Definition 1 5V Standby 2 Ground 3 Wake up ATX PS 2 Keyboard and PS 2 Mouse Ports The ATX PS 2 keyboard and the PS 2 mouse are located on the rear IO panel...

Страница 64: ...1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CM...

Страница 65: ...so be enabled in BIOS Note When enabled the user needs to write their own application software in order to disable the Watch Dog Timer Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Rese...

Страница 66: ...ormal Alarm Reset If three power supplies are installed and Alarm Reset JPRST1 is enabled the sys tem will notify you when any of the three power modules fails Connect JPRST1 to a micro switch to enab...

Страница 67: ...ED Settings Color Status Definition Green Flashing Active Rear View when facing the rear side of the chassis Activity LED Link LED Activity LED Link LED Onboard Power LED An Onboard Power LED is locat...

Страница 68: ...und 5 RX_N 6 RX_P 7 Ground Serial ATA Ports Six Serial ATA Ports I SATA0 I SATA 5 are located below the onboard battery on the motherboard These ports supported by Intel ICH10R South Bridge provide se...

Страница 69: ...h your motherboard Figure 5 12 Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right...

Страница 70: ...l system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDocto...

Страница 71: ...om our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we will recomm...

Страница 72: ...5 36 SUPERSERVER 7046GT TRF Series User s Manual Notes...

Страница 73: ...ing up your chassis Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver Figure 6 1 Chassis Front and Rear Views Front Control Panel Front...

Страница 74: ...back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the...

Страница 75: ...ssis contains two types of system fans mid system fans and rear system fans Replacing Mid System Fans Determine which fan has failed Because the fans are hot swappable the 1 chassis does not need to b...

Страница 76: ...6 4 SUPERSERVER 7046GT TRF Series User s Manual Rear Fan Release Tab Figure 6 4 Rear System Chassis Fans Figure 6 3 Mid System Chassis Fans Mid Fan Release Tab...

Страница 77: ...e in the system power must be completely removed from the server before removing and replacing the power supply for whatever reason Replacing the Power Supply With a redundant power supply the system...

Страница 78: ...8 pin motherboard cable 1 Motherboard Provides power to the motherboard CPU This cable has two black and two yellow wires 4 pin motherboard cable 1 Motherboard Provides power to PCI expansion card Th...

Страница 79: ...de and can be immediately used as desktop server If the chassis is to be used in a rack the storage module must be rotated 90 degrees and the storage moudule cover must be replaced see Figure 6 7 This...

Страница 80: ...to any component in the chassis Push the storage module release lever This lever unlocks the storage module 3 see Figure 6 8 Grasp the external edges of the storage module and pull the unit from the...

Страница 81: ...gure 6 9 includes three full sized drive bays and the front LED panel The storage module can be configured in one of three ways Add up to three extra hard drives to the drive trays Add up to three per...

Страница 82: ...ives to the drive carriers Adding Hard Drives to the Drive Carriers Open the chassis cover 1 Locate the drive tray release tab for the slot you want to place the peripheral 2 drive see Figure 6 10 Pus...

Страница 83: ...rd drive to the carrier with four screws from the bottom 5 Slide the hard drive into the chassis until the carrier clicks into place 6 Repeat these steps for each hard drive carrier 7 Warning Except f...

Страница 84: ...2 drive Push the drive tray toward the front of the chassis 3 Remove the hard drive tray rails from the hard drive tray To do this you must 4 remove two screws from each side see Figure 6 12 Attach th...

Страница 85: ...ote proper airflow for the drive bays Installing Hard Drives Unlock and open the chassis cover 1 Press the release button to extend the drive tray handle see Figure 6 14 2 Using the handle pull the dr...

Страница 86: ...e hard drive release button to extend the drive tray handle a Insert the hard drive into the chassis and close the handle to lock the hard b drive into place see Figure 6 16 Figure 6 16 Installing a H...

Страница 87: ...t be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left...

Страница 88: ...rect special incidental or consequential damages arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boo...

Страница 89: ...is item displays the type of CPU used in the motherboard Speed This item displays the speed of the CPU detected by the BIOS Physical Count This item displays the number of processors installed in your...

Страница 90: ...tions to be modified between POST messages or the OEM logo Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabl...

Страница 91: ...Watch Dog Timer will allow the system to reboot when it is inactive for more than 5 minutes The options are Enabled and Disabled Power Button Function If set to Instant_Off the system will power off...

Страница 92: ...the Multiple APIC Description Table MADT Select Modern Ordering for Microsoft Windows XP or later Select Legacy Ordering for Microsoft Windows 2000 or earlier The options are Modern Ordering and Lega...

Страница 93: ...ormance The options are Disable and Enabled C1E Support Select Enabled to use the feature of Enhanced Halt State C1E significantly reduces the CPU s power consumption by reducing the CPU s clock cycle...

Страница 94: ...system has detected to run at the frequency as specified The available options are Auto Force DDR 800 Force DDR 1066 Force DDR 1333 and Force SPD Memory Mode The options are Independent Channel Mirror...

Страница 95: ...this feature set to Enabled it will enhance overall system performance by providing direct cache access for data transferring The options are Enabled and Disabled DCA Prefetch Delay A DCA Prefetch is...

Страница 96: ...abled Enabled and Auto USB 2 0 Controller Select Enabled to activate USB 2 0 Controller The options are Enabled and Disabled Note If the item USB Functions is enabled USB 2 0 Controller will always be...

Страница 97: ...Base will appear When the option AHCI is selected the item ICH AHCI Codebase will be available ICH RAID Code Base Available when the option RAID is selected Select Intel to enable Intel s SATA RAID f...

Страница 98: ...hat supports 48 bit LBA mode The options are Disabled and Auto Block Multi Sector Transfer Block Mode boosts the IDE drive performance by increasing the amount of data transferred Only 512 bytes of da...

Страница 99: ...elect MWDMA1 to allow the BIOS to use Multi Word DMA mode 1 It has a data transfer rate of 13 3 MB s Select MWDMA2 to allow the BIOS to use Multi Word DMA mode 2 It has a data transfer rate of 16 6 MB...

Страница 100: ...I BIOS to configure all devices in the system PCI Latency Timer This feature sets the latency Timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to 64 PCI clock cycles Th...

Страница 101: ...al Port 1 and Serial Port 2 Select Disabled to prevent the serial port from accessing any system resources When this option is set to Disabled the serial port physically becomes unavailable Select 3F8...

Страница 102: ...This setting may not be supported by some operating systems Select Boot Loader to keep Console Redirection active during POST and Boot Loader The options are Disabled Boot Loader and Always Terminal...

Страница 103: ...mperature This feature displays current temperature readings for the CPU and the System The following items will be displayed for your reference only CPU 1 Temperature CPU 2 Temperature The CPU therma...

Страница 104: ...ED has activated take action immediately by checking the system fans chassis ventilation and room temperature to correct any problems Notes 1 The system may shut down if it continues for a long period...

Страница 105: ...does in synchronizing multimedia streams providing smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Per...

Страница 106: ...11 Trusted Computing Available for OEM Only TCG TPM Support Select Yes to enable support for trusted platforms TPM 1 1 1 2 and allow the BIOS to automatically download the drivers needed to provide su...

Страница 107: ...used in your system Status of BMC Baseboard Management Controller BMC manages the interface between system management software and platform hardware This is an informational feature which returns the...

Страница 108: ...e user will need to manually enter the IP address for the system If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server in the network that the system is attach...

Страница 109: ...g Mark all events as read This option marks all events as read The options are OK and Cancel Clear event log This option clears the Event Log memory of all messages The options are OK and Cancel PCIe...

Страница 110: ...access to the Setup Utility Select View Only to allow the user to view the Setup Utility displays without making any changes Select Limited to allow the user to make changes on limited items such as...

Страница 111: ...USB XXXXXXXXX Hard Disk Drives Use this feature to specify the boot sequence from all bootable HDD devices The settings are Disabled and a list of all hard disk drives that have been detected i e 1st...

Страница 112: ...ave completed the system configuration changes select this option to leave the BIOS Setup Utility and reboot the computer so the new system configuration parameters can take effect Select Save Changes...

Страница 113: ...cro be liable for direct indirect special incidental or consequential damages arising from a BIOS update If you need to update the BIOS do not shut down or reset the system while the BIOS is updating...

Страница 114: ...S ROM file is being updated When BIOS flashing is completed the computer will reboot Do not interrupt 4 the flashing process until it is completed 4 7 2 Boot Sector Recovery from an IDE CD ROM This pr...

Страница 115: ...ation parameters for the new connection Bits per second 115200 bits sec Data Bits 8 Parity None Stop Bit 1 Flow Control None Power on your system and click the Connect button in the Hyper Terminal 4 T...

Страница 116: ...inal to transfer the XModem protocol by using the Send File dialog under the Transfer menu follow the instructions below to complete XModem transfers a Select the Transfer menu and enter Send b Specif...

Страница 117: ...OS Serial Flash will work with any terminal communications program that supports VT 100 and XModem protocols including protocols designed for GNU LINUX BSD operating systems such as minicom It is reco...

Страница 118: ...7 32 SUPERSERVER 7046GT TRF Series User s Manual Notes...

Страница 119: ...hich will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs A 1 BIOS Error Beep Codes BIOS Error Beep...

Страница 120: ...A 2 SUPERSERVER 7046GT TRF Series User s Manual Notes...

Страница 121: ...booting up from the CD Press the F6 key when the message Press F6 if you need to install a third 2 party SCSI or RAID driver displays When the Windows XP Windows 2003 Setup screen appears press S to 3...

Страница 122: ...h the OS installation The Windows OS Setup screen will display 2 From the Windows setup screen press the Enter key The XP 2003 Setup 3 will automatically load all device files and then continue with t...

Страница 123: ...1066 800 MHz SDRAM or up to 48 GB of unbuffered ECC non ECC DDR3 1333 1066 800 MHz SDRAM Note See the memory section in Chapter 5 for details GPUs Graphics Processing Units 7046GT TRF No GPU cards ins...

Страница 124: ...Dimensions WxHxD 11 8 x 7 x 29 4 in 452 x 178 x 746 mm Weight Gross Bare Bone 72 lbs 32 7 kg System Cooling Four 9 2x3 8 cm and two 3 8 cm cooling fans fan speed controlled by BIOS setting System Inpu...

Страница 125: ...1000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations...

Страница 126: ...erform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such...

Отзывы: