6-14

SUPERSERVER 6027R-N3RF/WRF USER'S MANUAL

Figure 6-15: Replacing the Power Distributor

7.  Reconnect all the power cables, replace the power supply, and insert the plug 

into the wall.

Содержание SUPERSERVER 6027R-N3RF

Страница 1: ...SUPERSERVER 6027R N3RF 6027R WRF SUPER USER S MANUAL Revision 1 0a...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...lation This chapter describes the steps necessary to install the SuperServer 6027R N3RF WRF into a rack and check out the server configuration prior to powering up the system If your server was ordere...

Страница 4: ...chapter when installing removing or reconfiguring SAS SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction...

Страница 5: ...Notes Preface v...

Страница 6: ...Backplane 1 4 Cooling System 1 4 1 4 Advanced Power Management 1 4 Intel Intelligent Power Node Manager NM 1 4 Manageability Engine ME 1 4 1 5 Contacting Supermicro 1 6 Chapter 2 Server Installation...

Страница 7: ...r Fail 3 2 NIC1 3 2 NIC2 3 2 HDD 3 3 Power 3 3 3 4 Drive Carrier LEDs 3 3 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements 4 1 Warning Definition 4 1...

Страница 8: ...eference 5 14 5 8 Connector Definitions 5 16 5 9 Jumper Settings 5 25 Explanation of Jumpers 5 25 5 10 Onboard Indicators 5 27 5 11 SATA SAS Drive Connections 5 28 5 12 Installing Software 5 29 SuperD...

Страница 9: ...BIOS 7 1 Introduction 7 1 Starting the Setup Utility 7 1 7 2 Main Menu 7 1 System Time System Date 7 2 7 3 Advanced Settings Menu 7 2 7 3 Event Logs 7 22 7 4 IPMI 7 24 7 5 Boot 7 26 7 6 Security 7 27...

Страница 10: ...Notes viii SUPERSERVER 6027R N3RF WRF USER S MANUAL...

Страница 11: ...6 to 16 pin Ribbon Front Panel Control Cable CBL 0017L SAS SATA Accessories One 1 SAS SATA backplane BPN SAS 825TQ O P Two 2 30AWG 64 54 44 34 cm SAS connection cables CBL 0188L 02 for SuperServer 602...

Страница 12: ...are supported Please refer to Chapter 5 for installing memory Note LRDIMM Reduced Load memory supports only 1333 1066 800 MHz speed memory Serial ATA An on chip PCH C602 SATA controller is integrated...

Страница 13: ...egulators chassis and CPU overheat sensors power management AC power loss recovery virus protection and BIOS rescue 1 3 Server Chassis Features The SuperServer 6027R N3RF WRF is built upon the SC825TQ...

Страница 14: ...chassis has an innovative cooling design that includes three 8 cm hot plug system cooling fans located in the middle section of the chassis An air shroud channels the airflow from the system fans to...

Страница 15: ...P1 x1 x16 x16 x16 J1 Right Slot PCIE 3 0x16 DMI PE3 PE2 PE1 QPI QPI CPU Front DMI PE1 PE2 PE3 P0PE3 J3 Left Slot PCIE 3 0x16 x16 x4 Lane4 7 UL1 I350AM2 JLAN1 RJ45 JLAN2 RJ45 LaneReversal PolarityInver...

Страница 16: ...Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 17: ...ged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 6027R N...

Страница 18: ...stallation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack...

Страница 19: ...i unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipme...

Страница 20: ...ge includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail tha...

Страница 21: ...ils 1 Locate the rail assembly in the chassis packaging 2 Extend the rail assembly by pulling it outward 3 Press the quick release tab 4 Separate the inner rail extension from the outer rail assembly...

Страница 22: ...2 2 Assembling the Outer Rails Installing the Chassis into a Rack Figure 2 3 Warning Do not pick up the server with the front handles They are designed to pull the system from a rack only Stability Ha...

Страница 23: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Rack Rails Note The figure above is for illustrative purposes only Always install servers to the bottom of the rack first...

Страница 24: ...the inside of the server Checking the Components and Setup 1 You may have one or two processors already installed into the serverboard Each processor needs its own heat sink See Chapter 5 for instruc...

Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...

Страница 26: ...tem 3 Depending upon your system s configuration your system may have one or more drives already installed If you need to install hard drives please refer to Chapter 6 Checking the Airflow 1 Airflow i...

Страница 27: ...ity and health of specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a p...

Страница 28: ...cing the power supply This LED should be off when the system is operating normally NIC1 Indicates network activity on the LAN1 port when flashing NIC2 Indicates network activity on the LAN2 port when...

Страница 29: ...ions on replacing failed SATA drives Red When this LED flashes it indicates the drive is rebuilding When solid on it indicates a SATA drive failure If a drive fails you should be notified by your syst...

Страница 30: ...SUPERSERVER 6027R N3RF WRF USER S MANUAL 3 4 Notes...

Страница 31: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 32: ...equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a enco...

Страница 33: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 34: ...Anschlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de...

Страница 35: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 36: ...r and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortslu...

Страница 37: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 38: ...ment Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reempla...

Страница 39: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 40: ...the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden me...

Страница 41: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 42: ...erzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por...

Страница 43: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 44: ...nung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voor...

Страница 45: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 46: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might sti...

Страница 47: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 48: ...CSA UL CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kan...

Страница 49: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 50: ...ezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van U...

Страница 51: ...that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to...

Страница 52: ...t the power cord last and always remove it before adding removing or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink I...

Страница 53: ...RNING Press down on Load the Lever labeled Close 1st Pull lever away from the socket 3 With the lever labeled Close 1st fully retracted gently push down on the Open 1st lever to open the load plate Li...

Страница 54: ...CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Caution You can only...

Страница 55: ...te with the CPU inside the socket Lock the lever labeled Close 1st first then lock the lever labeled Open 1st second Use your thumb to gently push the load levers down to the lever locks OPEN1st OPEN1...

Страница 56: ...sink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard s and the Heatsink Bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until j...

Страница 57: ...ink to prevent damage done to the CPU or the CPU socket 1 Unscrew the heatsink screws from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it...

Страница 58: ...on cables for 6027R N3RF server only Two 2 AOC SAS connection cables for 6027R WRF server only Connecting Power Cables The X9DRW 3F iF has a 24 pin primary power supply connector designated JPW1 for c...

Страница 59: ...Fan Fail PWR Fail UID LED Ground Ground 2 1 20 19 5 4 I O Ports The I O ports are color coded to make setting up your system easier See Figure 5 2 below for the colors and locations of the various I O...

Страница 60: ...with DIMM 1A For best memory performance please install memory modules of the same type and same speed on the memory slots as indicated on the tables below 2 Insert each DIMM module vertically into i...

Страница 61: ...MF1 P1 DIMMC1 P1 DIMMD1 2 CPUs 8 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMMF1 P1 DIMMC1 P1 DIMMD1 P2 DIMMG1 P2 DIMMH1 2 CPUs 9 12 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMMF1 P1...

Страница 62: ...iser card is used to support PCI expansion cards in the system The riser card can support one UIO card and three full height full length PCI Express x8 expansion cards Installing a PCI Add on Card 1 R...

Страница 63: ...JPW2 JPW4 JPB1 FAN2 FAN1 FAN4 FANA FAN3 JPI2C1 LED3 LED1 COM2 JTAG OF CPLD SXB1A SXB1B CPU PCI E 3 0 x16 x16 P1 DIMMC1 CPU1 P1 DIMMC2 P1 DIMMD2 P1 DIMMD1 UID SXB2 CPU2 PCI E3 0 X16 LAN2 CPU2 LAN1 P1...

Страница 64: ...See Chapter 3 JI2C1 JI2C2 SMB to PCI E Slots Open Normal JPB1 BMC Enable Pins 1 2 Enabled JPG1 VGA Enable Pins 1 2 Enabled JPL1 LAN1 LAN2 Enable Pins 1 2 Enabled JWD1 Watch Dog Pins 1 2 Reset LED Desc...

Страница 65: ...Standby Power Connector LAN1 2 G bit Ethernet Ports 1 2 IPMI LAN IPMI_Dedicated LAN SATA SCU 0 3 4 7 Serial_Link SATA SCU Connections 0 3 4 7 for X9DRW 3F SCU 0 3 for X9DRW iF SP1 Onboard Buzzer Inter...

Страница 66: ...OM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V 12V 8 pin PWR Connector Pin Definitions JPW2 3 Pins Definition 1 through 4 Ground 5 through 8...

Страница 67: ...Pin Definitions JF1 Pin Definition 1 PW_ON 2 Ground Overheat Fan Fail LED OH Connect an LED cable to pins 7 and 8 of Front Control Panel to use the Overheat Fan Fail Power Fail and UID LED connection...

Страница 68: ...onnector is located on pins 15 and 16 of JF1 This connection is used to provide LED indication of power being supplied to the system See the table on the right for pin definitions Power LED Pin Defini...

Страница 69: ...C 5 Key NC No connection Backplane USB 0 1 2 3 Pin Definitions Pin Definition 1 5V 2 PO 3 PO 4 Ground 5 NA Ethernet Ports Two Gigabit Ethernet ports LAN1 2 are located on the I O backplane on the moth...

Страница 70: ...ware Monitoring in the Advanced Setting in the BIOS See Chapter 5 for more details See the table on the right for pin definitions Power LED Speaker On JD1 header pins 1 3 are used for power LED indica...

Страница 71: ...on the motherboard For more information on IPMI please refer to the IPMI User s Guide posted on our Website http www supermicro com UID Switch Pin Definition 1 Ground 2 Ground 3 Button In 4 Ground UID...

Страница 72: ...C1 monitors power supply fan and system temperatures See the table on the right for pin definitions PWR SMB Pin Definitions JI2C1 Pin Definition 1 Clock 2 Data 3 PWR Fail 4 Ground 5 3 3V Port 80 Heade...

Страница 73: ...k_On_Module devices is located at JSD1 Connect an appropriate cable here to provide power support for your DOM devices DOM Power Connector Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground SGPIO H...

Страница 74: ...ou must also have a cable to use this feature Standby Power Pin Definitions Pin Definition 1 5V Standby 2 Ground 3 Wake up Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherb...

Страница 75: ...is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down th...

Страница 76: ...ection See the table on the right for jumper settings BMC Enable Jumper JPB1 allows you to enable the embedded the Renesas BMC Baseboard Management Controller to provide IPMI 2 0 KVM support on the mo...

Страница 77: ...e two LAN ports LAN1 2 on the motherboard Each Ethernet LAN port has two LEDs The Yellow LED on the right indicates connection and activity The Link LED on the left side may be green amber or off to i...

Страница 78: ...d on the X9DRW iF These ports provide serial link signal connections which are faster than the connections of Parallel ATA See the table on the right for pin definitions Onboard Power LED An Onboard P...

Страница 79: ...ctory and locate the ISO file for your motherboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Anothe...

Страница 80: ...nt is called SD III Client The SuperDoctor III program allows you to monitor the environment and operations of your system SuperDoctor III displays crucial system information such as CPU temperature s...

Страница 81: ...ser s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories software SuperDoctorIII cfm For Linux we recommend that you use the SuperDoctor II applicati...

Страница 82: ...cturer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 5 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do...

Страница 83: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded m...

Страница 84: ...JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of...

Страница 85: ...on Press both tabs at the same time 3 Once the top cover is released from the locked position slide the cover toward the rear of the chassis 4 Lift the cover off the chassis Warning Except for short p...

Страница 86: ...ed period of time with the chassis open 2 Turn off the power to the system and unplug the system from the outlet 3 Remove the failed fan s power cord from the serverboard 4 Press the fan release tab t...

Страница 87: ...atches your chassis model Each shroud is labeled such as SC825LP or SC825U 2 Place air shroud in the chassis The air shroud fits behind the two fans closest to the power supply Note that if a 16 DIMM...

Страница 88: ...ns You must use standard 1 high SATA drives in the system Note Refer to the following ftp site for setup guidelines ftp ftp supermicro com driver SAS LSI LSI_SAS_EmbMRAID_SWUG pdf and Supermicro s web...

Страница 89: ...or obstruct the holes which aid in proper airflow Caution Regardless of how many hard drives are installed all drive carriers must remain in the drive bays to maintain proper airflow Installing Remov...

Страница 90: ...dummy drive to the carrier Figure 6 8 Chassis Drive Carrier Drive Carrier Dummy Drive Figure 6 9 Removing Dummy Drive from Carrier 1 1 1 1 2 Remove the dummy drive from the carrier 3 Install a new dr...

Страница 91: ...by tightening all six screws Figure 6 10 Removing the Hard Drive Drive Carrier SAS SATA Hard Drive 1 4 1 4 Figure 6 11 Installing the Hard Drive 1 5 5 Replace the drive carrier into the chassis bay ma...

Страница 92: ...he motherboard will hold the I O shield in place I O Shield Figure 6 12 I O Shield Placement Permanent and Optional Standoffs Standoffs prevent short circuits by securing space between the motherboard...

Страница 93: ...Secure the screw with the hexagon nut rounded side up 4 Lay the motherboard on the chassis aligning the permanent and optional standoffs 5 Secure the motherboard to the chassis using the rounded Phil...

Страница 94: ...power supply unit SC825 chassis models which include a redundant power supply will allow for the power supply to be replaced without powering down the system Replacement units can be ordered directly...

Страница 95: ...2 Remove all cable connections to the power supply from the motherboard backplane and other components Also remove both power supplies 3 Locate the power distributor between the power supply and the f...

Страница 96: ...6 14 SUPERSERVER 6027R N3RF WRF USER S MANUAL Figure 6 15 Replacing the Power Distributor 7 Reconnect all the power cables replace the power supply and insert the plug into the wall...

Страница 97: ...essage When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note that BIOS has default text messages built in We retain the option to include...

Страница 98: ...Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Cur...

Страница 99: ...ill power off immediately as soon as the user presses the power button If this feature is set to 4 Seconds Override the system will power off when the user presses the power button for 4 seconds or lo...

Страница 100: ...g Technology Intel VT x Technology Intel SMX Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache CPU Speed This item displays the speed of the CPU installed in Socket 1 Socket 2 64 bit This item...

Страница 101: ...e information Intel AES NI Select Enable to use the Intel Advanced Encryption Standard AES New Instructions NI to ensure data security The options are Enabled and Disabled Hardware Prefetcher Availabl...

Страница 102: ...y Efficient and Custom If the option is set to Custom the following items will display EIST Available when Power Technology is set to Custom EIST Enhanced Intel SpeedStep Technology allows the system...

Страница 103: ...gister The options are C0 C2 C6 and No Limit Factory Long Duration Power Limit This item displays the power limit set by the manufacturer during which long duration power is maintained Long Duration P...

Страница 104: ...logy significantly reduces CPU overhead by leveraging CPU architectural improvements freeing the system resource for other tasks The options are Disabled and Enabled DCA Support Select Enabled to use...

Страница 105: ...ink connections The options are Fast and Slow QPI Link Frequency Select Use this feature to select the desired QPI frequency The options are Auto 6 4 GT s 7 2 GT s and 8 0 GT s DIMM Configuration This...

Страница 106: ...uses two areas of memory to run the same set of operations in parallel The options are Independent Mirroring and Lockstep DRAM RAPL Mode RAPL Running Average Power Limit provides mechanisms to enforce...

Страница 107: ...rs found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error is corrected and sent to the requestor the orig...

Страница 108: ...ost Controller Interface Controller 1 or Controller 2 The options are Disabled and Enabled Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support legacy USB devices...

Страница 109: ...SATA Controller 1 The options for Controller 0 are Disabled Enhanced and Compatible The Options for Controller 1 are Disabled and Enhanced AHCI Mode The following items are displayed when the AHCI Mod...

Страница 110: ...eature to select the Option ROM to boot the system when there are multiple Option ROMs available in the system The options are EFI Compatible ROM and Legacy ROM PCI Latency Timer Use this feature to s...

Страница 111: ...ail CPU1 SXB 1A OPROM CPU1 SXB 1B OPROM CPU1 SXB 1C OPROM CPU2 SXB2 PCI E 3 0 x16 OPROM Select Enabled to enable Option ROM support to boot the computer using a network interface from the slots specif...

Страница 112: ...IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration Serial Port Select Enabled to enable a seria...

Страница 113: ...ap Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection M...

Страница 114: ...displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are D...

Страница 115: ...higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instr...

Страница 116: ...port the Intel Trusted Execution Technology CPU TXT Trusted Execution Technology Feature Chipset TXT Trusted Execution Technology Feature Intel TXT LT SX Configuration This feature displays the follow...

Страница 117: ...or which is a unique name used in the world Add an Attempt Delete Attempts Commit Changes and Exit Save the changes and exit from the page Discard Changes and Exit Discard the changes and exit from th...

Страница 118: ...from 0 second to 15 seconds The default setting is 0 second Port Configuration Information This menu displays the following information for a NIC port specified UEFI Driver Adapter PBA Chip Type PCI...

Страница 119: ...vent logs that exceed the limit when the SMBIOS event log is full Select Do Nothing for the system to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBI...

Страница 120: ...Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase a...

Страница 121: ...ou will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server in...

Страница 122: ...o boot the system from the network connection Select UEFI to boot the system from the UEFI Built in EFI Shell The options are LAN Device UEFI Built in EFI Shell and Disabled USB Device BBS Priorities...

Страница 123: ...puter Select Discard Changes and Exit and press Enter When the dialog box appears asking you if you want to exit the BIOS setup without saving click Yes to quit BIOS without saving the changes or clic...

Страница 124: ...User Defaults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults click Yes to...

Страница 125: ...with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond t...

Страница 126: ...A 2 SUPERSERVER 6027R N3RF WRF USER S MANUAL Notes...

Страница 127: ...f 1GB 2GB 4GB 8GB 16GB and 32GB size registered ECC SDRAM of up to DDR3 1600 1333 1066 800 MHz speed Note See the memory section in Chapter 5 for details SAS SATA Controller Intel PCH C602 on chip con...

Страница 128: ...ts AC Input Voltage 100 240V AC auto range Rated Input Current 9A 4A Rated Input Frequency 50 to 60 Hz Platinum 90 Platinum Level Power Supply Rated Output Power 740 Watt Part PWS 741P 1R Rated Output...

Страница 129: ...1000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations...

Страница 130: ...perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such...

Отзывы: