SUPERSERVER 6027R-N3RF/WRF USER'S MANUAL
3-2
1
2
3-3 Control Panel LEDs
The control panel located on the front of the chassis has several LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.
Power Fail
Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally.
NIC1
Indicates network activity on the LAN1 port when fl ashing.
NIC2
Indicates network activity on the LAN2 port when fl ashing.
•
Information LED:
See the following table for the status shown by this LED.
Information LED
Status
Description
Continously on and red
An overheat ocondition has occured. (This may be caused by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative power supply.
Solid blue
Local UID has been activated. Use this function to locate the server in a rack
environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this function to locate the server from a
remote location.
Содержание SUPERSERVER 6027R-N3RF
Страница 1: ...SUPERSERVER 6027R N3RF 6027R WRF SUPER USER S MANUAL Revision 1 0a...
Страница 5: ...Notes Preface v...
Страница 10: ...Notes viii SUPERSERVER 6027R N3RF WRF USER S MANUAL...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...
Страница 30: ...SUPERSERVER 6027R N3RF WRF USER S MANUAL 3 4 Notes...
Страница 126: ...A 2 SUPERSERVER 6027R N3RF WRF USER S MANUAL Notes...