Chapter 2: Server Installation
2-5
Figure 2-2. Identifying the Sections of the Rack Rails
(right side rail shown)
Inner Rail Extension
The
SC813TS-441CBP
chassis includes a set of inner rails which are in two
sections: inner rails and inner rail extensions. The inner rails are pre-attached and
do not interfere with normal use of the cha`sis if you decide not to use a server rack.
Attach the inner rail extension to stabilize the chassis within the rack.
Installing the Inner Rails
1. Place the inner rail extensions on the side of the chassis aligning the hooks
of the chassis with the inner rail extension holes. Make sure the inner rail
extension faces "outward" just like the pre-attached inner rail.
2. Slide the extension toward the front of the chassis.
3. Secure the chassis with 2 screws as illustrated.
4. Repeat steps 1-3 for the other inner rail extension.