ERVER 5018R-M/5018R-MR User's Manual
4. Gently pull upward to remove the failed fan from the housing.
5. Place the new fan into the vacant space in the housing. Make sure that the
arrows on the side of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
6. Plug the new fan's cable into the connector on the motherboard.
7. Plug the power cord into the rear of the power supply, power up the system
and check that the fan is working properly before replacing the chassis cover.
6-5 Drive Bay Installation/Removal
Accessing the Drive Bays
SATA Drives: Because of their hot-swap capability, you do not need to access the
inside of the chassis or power down the system to install or replace SATA drives.
Proceed to the next step for instructions.
Note:
The operating system you use must
have RAID support to enable the hot-swap capability of the drives.
DVD-ROM Drive: For installing/removing a DVD-ROM drive, you will need to gain
access to the inside of the server by removing the top cover of the chassis. Proceed
to the "DVD-ROM Drive Installation" section in this chapter for instructions. Note
that only a "slim" DVD-ROM drive will fit into the 5018R-M/5018R-MR.
Note:
A DVD drive does not come standard with the system.
Figure 6-3. Replacing System Fans
Содержание SUPERSERVER 5018R-M
Страница 1: ...SUPERSERVER 5018R M 5018R MR SUPER USER S MANUAL 1 0...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 SUPERSERVER 5018R M 5018R MR User s Manual Notes...
Страница 22: ...2 8 SUPERSERVER 5018R M 5018R MR User s Manual Notes...
Страница 26: ...3 4 SUPERSERVER 5018R M 5018R MR User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 5018R M 5018R MR User s Manual Notes...
Страница 82: ...6 10 SUPERSERVER 5018R M 5018R MR User s Manual Notes...
Страница 126: ...A 2 SUPERSERVER 5018R M 5018R MR User s Manual Notes...
Страница 130: ...B 4 SUPERSERVER 5018R M 5018R MR User s Manual Notes...