Страница 1: ...SUPERSERVER 5017R WRF SUPER USER S MANUAL 1 0...

Страница 2: ...ny such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits f...

Страница 3: ...the SC815TQ R500WB chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the 5017R WRF into a rack and check out the server configuration prior to powering up th...

Страница 4: ...e motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC815TQ R500WB server chas sis You should follow the procedures given in this chapter when installing...

Страница 5: ...Notes Preface v...

Страница 6: ...1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3...

Страница 7: ...Motherboard 5 1 Precautions 5 1 Unpacking 5 1 5 2 Processor and Heatsink Installation 5 2 Installing an LGA2011 Processor 5 2 Installing a CPU Heatsink 5 5 Removing the Heatsink 5 5 5 3 Connecting Ca...

Страница 8: ...ccessing the Drive Bays 6 5 Hard Drive Installation 6 6 DVD ROM and Floppy Drive Installation 6 8 6 5 Power Supply 6 9 Power Supply Failure 6 9 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup...

Страница 9: ...permicro com In addition to the motherboard and chassis various hardware components have been included with the 5017R WRF as listed below Three 4 cm chassis fans FAN 0086L4 One passive CPU heatsink SN...

Страница 10: ...ted The SATA drives are hot swappable units Two of the ports support SATA 3 0 6 Gb s while the other four are SATA 2 0 3 Gb s ports Note You must have RAID set up to enable the hot swap capability of...

Страница 11: ...or removing a single power supply module Hard Drive Subsystem The SC815TQ R500WB chassis was designed to support four hot swap SATA hard drives Front Control Panel The chassis control panel provides...

Страница 12: ...5 6 7 COM2 Header SLOT 4 USB 2 0 6 0 Gb S Sandybridge EP PCH PATSBURG SSB D PCI E X16 G3 BIOS SIO NCT6776F LPC USB 0 1 2 4 5 SATA 0 1 2 Rear 6 Front 1 Type A PCI E X4 G2 PCI E X8 LAN 1 2 PCI E X16 8...

Страница 13: ...dress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl T...

Страница 14: ...1 6 SUPERSERVER 5017R WRF User s Manual Notes...

Страница 15: ...y If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 5017R WRF It should be situated...

Страница 16: ...e fully extended to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be...

Страница 17: ...quipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condi...

Страница 18: ...e with the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting kit Each assembly consists of two sections an inner...

Страница 19: ...bracket to the front side of the outer rail with two screws and the long bracket to the rear side of the outer rail with three screws Repeat these steps for the left outer rail Locking Tabs Both chass...

Страница 20: ...it The next step is to install the server into the rack Do this by lining up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pres...

Страница 21: ...rmine how far follow the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove it T...

Страница 22: ...2 8 SUPERSERVER 5017R WRF User s Manual Notes...

Страница 23: ...apter explains the meanings of all LED indicators and the appropriate response you may need to take 3 2 Control Panel Buttons There are three push buttons located on the front of the chassis a reset b...

Страница 24: ...l UID Button Depressed Blinking Blue IPMI Activated UID Note deactivating the UID LED must be performed in the same way it was activated If the UID LED was activated via IPMI you can only turn the LED...

Страница 25: ...k activity on LAN1 when flashing HDD Indicates IDE channel activity On the SuperServer 5017R WRF this light indicates SATA and or DVD ROM drive activity when flashing Power Indicates power is being su...

Страница 26: ...ivity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LED indicates two states When blinking it indicates the drive is...

Страница 27: ...wer you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits a...

Страница 28: ...ody which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Motherboard Battery CAUTION T...

Страница 29: ...il ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if yo...

Страница 30: ...tice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may...

Страница 31: ...at the size and weight of the motherboard can cause it to bend if handled improperly which may result in damage To prevent the motherboard from bending keep one hand under the center of the board to s...

Страница 32: ...e you install the CPU heatsinks When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise cont...

Страница 33: ...ARNING plastic cap from the socket 3 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 4 Once they are aligned caref...

Страница 34: ...ain and double check that the CPU is aligned properly 1 With the CPU in the socket in spect the four corners of the CPU to make sure that they are flush with the socket 2 Close the load plate Lock the...

Страница 35: ...apply the proper amount of thermal grease before you re install the heatsink Removing the Heatsink Warning We do not recommend removing the CPU or the heatsink If you do need to remove the heatsink pl...

Страница 36: ...cable JF1 see next page SATA cables I SATA0 I SATA5 and or S SATA1 S SATA4 Connecting Power Cables The X9SRW F has a 24 pin primary power supply connector designated JPW1 for connection to the ATX po...

Страница 37: ...5 2 below for the colors and locations of the various I O ports Figure 5 2 Rear Panel I O Ports Rear I O Ports 1 COM1 Port 6 USB3 2 USB1 7 LAN1 Port 3 USB0 8 LAN2 Port 4 IPMI LAN Port 9 VGA Port 5 US...

Страница 38: ...int on the slot 4 Use two thumbs together to press on both ends of the module straight down into the slot until the module snaps into place 5 Press the release tabs to the lock positions to secure the...

Страница 39: ...refer to Chapter 5 for installing memory Populating these DIMM modules with a pair of memory modules of the same type and same size will result in interleaved memory which will improve memory perform...

Страница 40: ...should install DIMM modules in pairs Recommended Population Balanced DIMM1A DIMM2A DIMM3A DIMM4A DIMM1B DIMM2B DIMM3B DIMM4B Total System Memory 2GB 2GB 4GB 2GB 2GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 2GB 2G...

Страница 41: ...in the system The RSC R1UW E8R riser card can support a PCI E 3 0 x8 card and the RSC R1UW 2E16 can support two PCI E 3 0 x16 cards Installing a PCI Add on Card 1 Release the locking tab that corresp...

Страница 42: ...TPM PORT80 DIMM4A DIMM4B DIMM3B DIMM3A KB MOUSE USB 2 3 JTPM1 TPM PORT80 JSTBY1 STAND BY POWER FOR DOM 2 3 NMI 1 2 RST DEFAULT JWD WATCH DOG TIMER JD1 4 7 SPEAKER 1 2 PWR_LED IPMI LAN USB 0 1 1 2 ENAB...

Страница 43: ...ers JTPM1 Trusted Platform Module TPM Header JSTBY1 Legacy Wake On LAN Header USB0 1 USB2 3 Back panel USB 2 0 ports USB4 5 USB4 5 Internal USB 2 0 headers JIPMB System Management Bus Header for the I...

Страница 44: ...s 1 2 Enabled JPME1 Intel ME Mode Select Pins 1 2 Normal UID Unit ID Switch Off Disabled JWD Watch Dog Timer Reset Pins 1 2 Reset JPB1 IPMI BMC Enable Disable Pins 1 2 Enabled JP3 BIOS Recover Pins 2...

Страница 45: ...ns Definition 1 through 4 Ground 5 through 8 12V Power LED Pin Definitions JF1 Pin Definition 15 Vcc 16 Control Processor Power Connectors JPW2 and JPW3 must also be con nected to the power supply to...

Страница 46: ...D LED connection is located on pins 13 and 14 of JF1 Attach a hard drive LED cable to display SATA IDE disk activity Refer to the table on the right for pin definitions HDD LED Pin Definitions JF1 Pin...

Страница 47: ...B 2 0 ports are included with the rear I O ports There are also four USB 2 0 ports on two headers that can be used to provide front chassis access see board layout for loca tions See the tables on the...

Страница 48: ...NC Fan Header Pin Definitions Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control Speaker JD1 On the JD1 header pins 3 4 are used for the internal speaker Close pins 3 4 with a jumper...

Страница 49: ...JPI2 C is used to moni tor the power supply fan and system temperatures See the table on the right for pin definitions PWR SMB Pin Definitions JPI2 C Pin Definition 1 Clock 2 Data 3 PWR Fail 4 Ground...

Страница 50: ...so located next to USB 8 9 These headers are used to communicate with the enclosure management chip in the system See the table on the right for pin definitions Trusted Platform Module Header Pin Defi...

Страница 51: ...clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and...

Страница 52: ...When enabled the user needs to write their own application software to disable the Watch Dog Timer LAN Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Watch...

Страница 53: ...umper Settings Pin Definition 1 Normal Default 2 Ground 3 Force Update VRM SMB Clock Data The VRM SMB Clock Data is used to select where the Voltage Regula tor Module s System Management Bus clock sig...

Страница 54: ...BIOS Recovery JP3 is used to enable or disable the BIOS Recovery feature of the motherboard Install the jumper on pins 1 2 to begin the recovery process ME Recovery Pin Definitions Pin Definition 1 N...

Страница 55: ...ower cord before removing or install ing components See the tables at right for more information Onboard PWR LED Indicator LED Color Definition Off System Off Power cable not connected Green System On...

Страница 56: ...D Toggled On Onboard Standby Power LED Indicator Status Definition Off Power Supply is Off Hard Switch On Power Supply is On Hard Switch Onboard Standby Power LED An onboard Standby Power LED LED2 ind...

Страница 57: ...ed with your motherboard Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of th...

Страница 58: ...rucial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the SuperDoctor III interface Note The default User Name and Password for SuperDo...

Страница 59: ...ctor III program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories software SuperDoctorIII cfm For Linux we recommend using SuperDoctor I...

Страница 60: ...5 30 SUPERSERVER 5017R WRF User s Manual Notes...

Страница 61: ...vent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a...

Страница 62: ...e cable from JF1 on the motherboard to the appropriate header on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of t...

Страница 63: ...an continue to run with a failed fan Remove the top chassis cover while the system is still running to determine which of the two fans has failed Then power down the system before replacing a fan Remo...

Страница 64: ...emove it to gain access to the drive bays To remove the bezel first unlock the front of the chassis then press the release knob see Figure 6 3 Carefully re move the bezel with both hands A filter loca...

Страница 65: ...nstructions DVD ROM Floppy Disk Drives For installing removing a DVD ROM or floppy disk drive you will need to gain access to the inside of the 5017R WRF by removing the top cover of the chassis Proce...

Страница 66: ...t board side facing down so that the mounting holes align with those in the carrier 2 Secure the drive to the carrier with six screws as shown in Figure 6 4 Figure 6 4 Mounting a Hard Drive in a Carri...

Страница 67: ...airflow Installing Removing a Hard Drive 1 To remove a carrier push the release button located beside the drive LEDs 2 Swing the colored handle fully out and use it to pull the unit straight out see...

Страница 68: ...ss to the inside of the server Removing Installing a Drive 1 With the chassis cover removed unplug the power and data cables from the drive you want to remove 2 Locate the locking tab at the rear of t...

Страница 69: ...eface The power supply modules have a hot swap capability meaning you can replace the failed module without powering down the system Replacing the Power Supply You do not need to shut down the system...

Страница 70: ...6 10 SUPERSERVER 5017R WRF User s Manual Figure 6 6 Removing Replacing the Power Supply...

Страница 71: ...s The left frame displays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the...

Страница 72: ...not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special i...

Страница 73: ...This item displays the day and time when this version of BIOS was built SMC Version This item displays the SMC Version of the BIOS used in th system Memory Information Total Memory This displays the a...

Страница 74: ...E OpROM The options are Enabled and Disabled Launch Storage OpROM The options are Enabled and Disabled PCI Subsystem Settings PCI Bus Driver Version This item displays the current driver version PCI O...

Страница 75: ...to inform the onboard PCI devices that an ISA graphics device is installed in the system in order for the graphics card to function properly The options are Enabled and Disabled PERR Generation Set th...

Страница 76: ...allows the user to decide how many attempts a software program can make before time out for the program The default setting is 5 The options are Disabled 2 3 and 5 Link Training Timeout US This featu...

Страница 77: ...Egress Exiting ports wil be blocked The op tions are Disabled and Enabled IDO ID Based Ordering Request Enable Available if supported by a device If this feature is set to Enabled and is supported by...

Страница 78: ...e options are Disabled and Enabled Hardware Autonomous Width Select Disabled to disable hardware s ability to change PCI E link width except width reduction to correct operational errors if this featu...

Страница 79: ...ing Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the motherboard to allow TPM support to improve data integrity and network security The options are Enabled and D...

Страница 80: ...nd health monitoring The default setting is Enabled CPU Configuration This submenu displays the information of the CPU as detected by the BIOS It also allows the user to configure CPU settings CPU Inf...

Страница 81: ...can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and...

Страница 82: ...d uses The options are Disabled Energy Efficient and Custom If Custom is selected the following options become available EIST EIST Enhanced Intel SpeedStep Technology allows the system to auto matical...

Страница 83: ...This item displays the period of time set by the manufacturer during which long duration power is maintained Long Duration Maintained This item displays the period of time during which long duration p...

Страница 84: ...owing are displayed depending on your selection IDE Mode The following items are displayed when IDE Mode is selected Serial ATA SATA Controller 0 1 Use this feature to activate or dactivate the SATA c...

Страница 85: ...be displayed OnChip SAS Oprom Select Enabled to support the onboard SAS Option ROM to boot up the system via a storage device if a SAS device is installed SAS Option ROM Codebase Select Intel to use t...

Страница 86: ...by the operating systems that do not recognize a USB device The options are Disabled and Enabled USB Hardware Delays and Time outs USB Transfer Time out Use this item to set the time out value for co...

Страница 87: ...ct the desired mode for a serial port specified The options are Normal and High Speed ME Management Engine Updates ME Updates Select Enabled to update ME settings The options are Enabled and Disabled...

Страница 88: ...ng with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the numbe...

Страница 89: ...RMR6 SCO ESCN and VT400 Out of Band Mgmt Port Use this feature to select the port for out of band management The options are COM0 and COM1 Serial Port for Out of Band Management Windows Emergency Mana...

Страница 90: ...ms will be displayed Initiator IP Address Initiator Subnet Mask Gateway Target Name Target IP Address Target Port Boot LUN CHAP Type Use this item to select CHAP type The options are None One Way and...

Страница 91: ...ion Intel VT for Directed I O Configuration Intel VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to the VMM Virtual W...

Страница 92: ...Cache Access Technolgy to improve data transfer efficiency The options are Enabled and Disabled VGA Priority Use this feature to specify which graphics controller to be used as the primary boot device...

Страница 93: ...GEN2 IOU2 PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU2 and PCIe port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto IOU3 PCIe Port This feature allow...

Страница 94: ...Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor the original source When this...

Страница 95: ...set the altitude of the operating environment for the system as indicated by the number of meters above the sea level The options are Auto 300 M Meters 900 M 1500 M and 3000 M Serial Message Debug Lev...

Страница 96: ...d SLP_S4 Assertion Width This item sets the minimum assertion width of the SLP _S4 signal to ensure that DRAMs power cycles are safe The options are 1 2 seconds 2 3 seconds 3 4 seconds and 4 5 seconds...

Страница 97: ...ort 1 8 The options are Enabled Disabled and Auto PCIe Sub Decode The options are Enabled and Disabled DMI Vc1 Vcp Vcm Control The options are Enabled and Disabled USB Universal Serial Bus Configurati...

Страница 98: ...ious tasks in the background The options are Enabled and Disabled When ME Subsystem is enabled the following items will display ME BIOS Interface ME Version ME FW Firmware Status Value ME FW Firmware...

Страница 99: ...Controller The op tions are Enabled and Disabled Wait for BMC Select Enabled for the system to wait for the host controller to initiate and to interface with the BMC at bootup The options are Disable...

Страница 100: ...s to take effect BMC Network Configuration LAN Channel 1 LAN Channel 2 This feature allows th user to configure the settings for LAN Channel 1 or LAN Channel 2 Update IPMI LAN Configuration This featu...

Страница 101: ...exceed 255 Station MAC Address This item displays the Station Mac address for this computer Mac addresses are 6 two digit hexadecimal numbers Router IP Address This item displays the Router IP address...

Страница 102: ...ed above 1 MB The options are Upon Request and Always Option ROM Messages This item allows the user to decide how the Option ROM Message is displayed Select Keep Current to use the current Option ROM...

Страница 103: ...Shell and Disabled The default setting for the first boot drive is UEFI Network Card The default setting for the second boot drive is IBA GE Slot 0700 v1371 The default setting for the third boot dri...

Страница 104: ...o enter the BIOS setup utility The length of the password should be from 3 characters to 8 characters long 7 8 Save Exit This submenu allows the user to configure the Save and Exit settings for the sy...

Страница 105: ...t the computer Select Discard Changes and Reset from the Exit menu and press Enter When the dialog box appears asking you if you want to exit the BIOS setup without saving click Yes to quit BIOS witho...

Страница 106: ...s defaults previously saved in the system When the dialog box appears asking you if you want to restore user s defaults click Yes to restore the user s defaults previously saved in the system or clic...

Страница 107: ...rror oc curs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list cor...

Страница 108: ...A 2 SUPERSERVER 5017R WRF User s Manual Notes...

Страница 109: ...t DIMM sockets support up to 256 GB of DDR3 1600 1333 1066 ECC R LRDIMMs or up to 64GB of ECC UDIMMs See the memory section in Chapter 5 for details SATA Intel on chip controllers support ten SATA por...

Страница 110: ...Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A E...

Страница 111: ...B 3 Appendix B System Specifications Notes...

Страница 112: ...rform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such p...