Страница 1: ...SUPERSERVER 5017C LF SUPER USER S MANUAL 1 0...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...included with the server system and describes the main features of the X9SCL F serverboard and the SC510L 200B chassis which comprise the SuperServer 5017C LF Chapter 2 Server Installation This chapte...

Страница 4: ...and jumpers Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information...

Страница 5: ...v Preface Notes...

Страница 6: ...cking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Ai...

Страница 7: ...talling the LGA1155 Processor 5 2 Installing a Passive CPU Heatsink 5 4 Removing the Heatsink 5 4 5 3 Connecting Cables 5 6 Connecting Data Cables 5 6 Connecting Power Cables 5 6 Connecting the Contro...

Страница 8: ...7 1 Introduction 7 1 7 2 Main Setup 7 2 7 3 Advanced Setup Configurations 7 4 7 4 Event Logs 7 15 7 5 IPMI Configuration X9SCL F X9SCM F Only 7 16 7 6 Boot Settings 7 18 7 7 Security Settings 7 19 7...

Страница 9: ...ing systems that have been certified for use with the system www supermicro com In addition to the motherboard and chassis various hardware components have been included with the 5017C LF as listed be...

Страница 10: ...f unbuffered DDR3 1333 1066 memory Please refer to Chapter 5 for installing memory Serial ATA An on chip SATA controller is integrated into the X9SCL F to provide a six port 3 Gb sec Serial ATA subsys...

Страница 11: ...ot hot swappable Control Panel The SC510L 200B s control panel provides important system monitoring and con trol information LEDs indicate power on network activity hard disk drive activity and system...

Страница 12: ...RJ45 DDR3 CHB DIMM1 DIMM2 Far DIMM1 DIMM2 Far 4 UDIMM MISC VRs 1333 1066MHz 1333 1066MHz 5 0Gb x4 DMI II 5 0Gb 5 0Gbps PCIe_x4 PCIe x8 Slot 6 SATA Ports SATA II 300MB s 9 USB Ports USB2 0 480Mbps Flas...

Страница 13: ...per Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical...

Страница 14: ...1 6 SUPERSERVER 5017C LF User s Manual Notes...

Страница 15: ...ay If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in...

Страница 16: ...f the rack are fully extended to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the ra...

Страница 17: ...quipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condi...

Страница 18: ...hould also refer to the installation instructions that came with the rack unit you are using Note the server may be installed as is rack hardware is optional Basic Installation Procedure Confirm that...

Страница 19: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing the Chassis into a Rack...

Страница 20: ...Checking the Components You may have a processor already installed into the serverboard The proces 1 sor should have its own heatsink attached See Chapter 5 for instructions on processor installation...

Страница 21: ...t layout was care 1 fully designed to promote sufficient airflow through the small 1U rackmount space Also note that all power and data cables have been routed in such a way that 2 they do not block t...

Страница 22: ...2 8 SUPERSERVER 5017C LF User s Manual 1 1 1 2 1 1 1 1 Figure 2 1 Removing the Chassis Cover...

Страница 23: ...panel This chapter explains the meanings of all LED indicators and the appropriate response you may need to take 3 2 Control Panel Buttons There are two push buttons located on the front of the chass...

Страница 24: ...Fail When this LED flashes it indicates a fan failure When on continuously on and not flashing it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or...

Страница 25: ...3 HDD Channel activity for HDDs This light indicates IDE drive activity when flashing Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated...

Страница 26: ...3 4 SUPERSERVER 5017C LF User s Manual Notes...

Страница 27: ...wer you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits a...

Страница 28: ...be connected to an IT power system In all cases make sure that the unit is also reliably connected to Earth ground Serverboard Battery CAUTION There is a danger of explosion if the onboard battery is...

Страница 29: ...PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules o...

Страница 30: ...ice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may...

Страница 31: ...at the size and weight of the motherboard can cause it to bend if handled improperly which may result in damage To prevent the motherboard from bending keep one hand under the center of the board to s...

Страница 32: ...tsink only Make sure to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre installed make sure that the plastic CPU sock...

Страница 33: ...CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damage to the CPU or the socket With the CPU inside the socket inspect the four corner...

Страница 34: ...nk on top of the CPU so that the four mounting holes are 2 aligned with those on the motherboard and the heatsink bracket underneath Screw in two diagonal screws i e the 1 and the 2 screws until just...

Страница 35: ...the CPU socket 3 Clean the surface of the CPU and the heatsink removing the used thermal 4 grease Reapply the proper amount of thermal grease on the surface before re installing the CPU and the heats...

Страница 36: ...ta cables with their motherboard connector locations noted should be connected See the motherboard layout diagram in this chapter for connector locations DVD ROM Drive cable SATA0 Control Panel cable...

Страница 37: ...ons section in this chapter for details and pin descrip tions of JF1 5 4 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and loc...

Страница 38: ...ps into place in the slot 2 Repeat fstep 1 to install to DIMM1B if needed Memory Support The X9SCL F supports up to 32GB of ECC unbuffered UDIMM DDR3 1333 1066 memory in four memory slots Populating t...

Страница 39: ...ty System Device Size Physical Memory Remaining Available 4 GB Total System Memory Firmware Hub flash memory System BIOS 1 MB 3 99 Local APIC 4 KB 3 99 Area Reserved for the chipset 2 MB 3 99 I O APIC...

Страница 40: ...d The riser card provides a PCI E x8 signal PCI Card Installation When installing a PCI add on card make sure you install it into a slot that supports the speed of the card Swing out the release tab o...

Страница 41: ...A 0 1 X9SCL SATA2 X9SCM SATA3 Socket H2 LGA 1155 CPU I SATA4 I SATA5 I SATA3 I SATA1 I SATA0 Slot5 PCI E 2 0 x4 on x8 USB 0 1 LAN1 LAN2 LE7 JPME1 JPME2 1 4 1 1 1 2 1 3 1 5 1 7 1 8 1 10 1 13 1 14 1 15...

Страница 42: ...24 pin ATX Main Power Connector 47 JPW2 12V 8 pin CPU power Connector 1 KB Mouse Keyboard Mouse Connectors 8 9 3 LAN1 LAN2 IPMI LAN Gigabit RJ45 Ports LAN1 2 IPMI_LAN F models 49 50 25 7 24 I SATA 0...

Страница 43: ...ll VRMs See the table on the right for pin definitions ATX Power 24 pin Connector Pin Definitions JPW1 Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 CO...

Страница 44: ...ilure Refer to the table on the right for pin definitions OH Fan Fail LED Pin Definitions JF1 Pin Definition 7 Vcc Blue UID LED 8 OH Fan Fail LED OH Fan Fail Indicator Status State Definition Off Norm...

Страница 45: ...P2 8 USB_PP3 4 Ground 9 Ground 5 No Con nection 10 Key Serial Ports The COM1 Port is located on the I O backpanel COM2 is a header located on the the motherboard See the table on the right for pin def...

Страница 46: ...ated at JL1 on the motherboard Attach the ap propriate cable from the chassis to inform you of a chassis intrusion when the chas sis is opened ATX PS 2 Keyboard and PS 2 Mouse Ports The ATX PS 2 keybo...

Страница 47: ...1 Trusted Platform Module Header This header is used to connect a Trusted Platform Module TPM available sepa rately from a third party vendor A TPM is a security device that allows encryption and auth...

Страница 48: ...Pur pose Input Output headers are located near the SATA connectors on the moth erboard These headers are used to com municate with the enclosure management chip in the system See the table on the rig...

Страница 49: ...clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS First power down the system and un...

Страница 50: ...used together with the IPMI set tings in the BIOS The default position is on pins 1 and 2 to Enable BMC See the table on the right for jumper settings BMC IPMI Enable Disable Jumper Settings Settings...

Страница 51: ...ht indicates activity while the green LED on the left indicates the speed of the connection See the tables at right for more information IPMI LAN Link LED Left Activity LED Right LED Color Definition...

Страница 52: ...tions SATA Ports Six Serial ATA SATA ports I SATA 0 5 are located on the motherboard See the table on the right for pin definitions for the onboard SATA ports SATA Port Pin Definitions SATA0 SATA5 Pin...

Страница 53: ...omputer icon and then on the icon representing your CD ROM drive Finally double click on the S Setup icon Figure 5 4 Driver Installation Display Screen Click the icons showing a hand writing on paper...

Страница 54: ...al system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDoct...

Страница 55: ...oaded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download SDIII User s Guide at http www supermicro com manuals other SDIII_User_Guide pdf For Linux we will sti...

Страница 56: ...5 26 SUPERSERVER 5017C LF User s Manual Notes...

Страница 57: ...prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Us...

Страница 58: ...anel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 for details...

Страница 59: ...a failed fan Replacing System Fans Figure 6 2 If necessary remove the top chassis cover while the power is running to 1 determine which fan has failed Never run the server for an extended period of ti...

Страница 60: ...e tray 2 Install a drive with the printed circuit board side facing down and so that the 3 mounting holes align with those in the chassis Secure the drive to the chassis with screws 4 Replace the top...

Страница 61: ...hassis Setup 6 5 Figure 6 3 Installing Internal Hard Drives The 3 5 hard drive screws directly into the chassis The 2 5 hard drives 1 must be installed in their brackets 2 before they are screwed into...

Страница 62: ...w to maximize fan efficiency The SC510L 200B chas sis air shroud does not require screws to set up Place the air shroud in the chassis The air shroud fits behind the fan closest 1 to the power supply...

Страница 63: ...o the chassis The 3 two front mounting screws are located on the front of the power supply The two rear mounting screws are accessed on the underside of the chassis and extend upwards through the moun...

Страница 64: ...6 8 SUPERSERVER 5017C LF User s Manual Figure 6 5 Installing the Power Supply Power Supply Mounting Holes Front Mounting Screws Rear Mounting Screws...

Страница 65: ...all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area res...

Страница 66: ...e to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boot failure 7 2 Main Setup When you first enter the AMI BIOS Setup Utility you will ente...

Страница 67: ...r the arrow keys to move between fields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17...

Страница 68: ...ait For F1 If Error This forces the system to wait until the F1 key is pressed if an error occurs The options are Disabled and Enabled Interrupt 19 Capture Interrupt 19 is the software interrupt that...

Страница 69: ...on AC Power Loss Use this feature to set the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned o...

Страница 70: ...ation code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer t...

Страница 71: ...frequency in specific conditions The options are Disabled and Enabled Long duration power limit this is the processor power consumption limit in Watts during a long duration time window Long duration...

Страница 72: ...s power saving and transaction speed The options are Enabled and Disabled PCIE Maximum Payload Size This feature selects the setting for the PCIE maximum payload size The options are Auto 128 Bytes 25...

Страница 73: ...ange will be claimed by the EHCI driver The settings are Enabled and Disabled IDE SATA Configuration When this submenu is selected the AMI BIOS automatically detects the presence of the IDE Devices an...

Страница 74: ...eSATA support The options are Enabled and Disabled Hot Plug Set this item to Enabled to enable hot plugging The options are Enabled and Disabled RAID Mode The following items are displayed when RAID...

Страница 75: ...e onboard option ROMs The options are Disabled and Enabled Boot Graphics Adapter Priority Use the feature to select the graphics controller to be used as the primary boot device The options are Offboa...

Страница 76: ...ost common settings are set as default Terminal Type Select ANSI VT100 VT100 or VT UTF8 Bits per Second BPS 9600 19200 57600 or 115200 Data Bits 8 or 7 Parity None Even Odd Mark or Space Stop Bits 1 o...

Страница 77: ...are Full Speed 100 of PWM Cycle Standard 50 of PWM Cycle and Optimal 30 of PWM Cycle CPU Temperature Display Mode This feature displays the CPU temperature detected by DTS i e 34o C or tem perature s...

Страница 78: ...h Performance Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing t...

Страница 79: ...unter counts the number of oc curences a duplicate event must happen before the MECI counter is incremented This is a numeric value METW The Multiple Event Time Window METW defines number of minutes m...

Страница 80: ...MC interfaces The options are Disabled and Enabled BMC Self Test Log This feature logs any BMC messages returned during a BMC self test It shows the total number of entries and will allow the viewing...

Страница 81: ...This feature selects whether the IP address Subnet Mask and Gateway Address are automatically assigned by the network s DHCP server Dynamic Host and Con figuration Protocol Dynamic or manually entere...

Страница 82: ...option 2 Boot Option 3 etc The settings are Built in EFI Shell any detected boot device and Disabled BIOS SETUP UTILTY Main Advanced Security Boot Exit Select Screen Select Item Enter Select Change Op...

Страница 83: ...command or attempts to write to the boot sector of the hard disk drive The options are Enabled and Disabled BIOS SETUP UTILTY Main Advanced Security Boot Exit Select Screen Select Item Enter Select C...

Страница 84: ...Exit from the Exit menu and press Enter Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS Utility Program Restore Defaults To set this feature se...

Страница 85: ...ave any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press En ter Use this feature to retrieve user defined se...

Страница 86: ...7 22 SUPERSERVER 5017C LF User s Manual Notes...

Страница 87: ...rror oc curs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list cor...

Страница 88: ...A 2 SUPERSERVER 5017C LF User s Manual Notes...

Страница 89: ...Four DIMM sockets supporting up to 32 GB of unbuffered DDR3 1333 1066 memory See the memory section in Chapter 5 for details SATA Controller Intel on chip controller for six port Serial ATA RAID 0 1 5...

Страница 90: ...non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Imm...

Страница 91: ...B 3 Appendix B System Specifications Notes...

Страница 92: ...form be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pr...

Отзывы: