3-2
S
UPER
S
ERVER 1027GR-TRF/1027GR-TRFT User's Manual
2
1
NIC2
Indicates network activity on GLAN2 when
fl
ashing .
3-3 Control Panel LEDs
The two control panels are located on the front of the SC118GQ chassis. Each
control panel has six LEDs. These LEDs provide critical information related to dif-
ferent parts of the system. This section explains what each LED indicates when
illuminated and any action that may be required..
NIC1
Indicates network activity on GLAN1 when
fl
ashing .
Overheat/Fan Fail/UID LED
When this LED
fl
ashes it indicates a fan failure. When continuously on (not
fl
ash-
ing) it indicates an overheat condition, which may be caused by cables obstructing
the air
fl
ow in the system or the ambient room temperature being too warm. Check
the routing of the cables and make sure that all fans are present and operating
normally. Also check to make sure that the air shrouds are installed and that the
top cover is on. Finally, verify that the heatsinks are installed properly. This LED
will remain
fl
ashing or on as long as the overheat condition exists. When used with
a UID-compatible motherboard, the UID function is used to turn on or off the blue
light function of the the LED. Once the blue light is activated through the system
software, the unit can be easily located in very large racks and server banks.
Содержание SUPERSERVER 1027GR-TRF
Страница 2: ...SUPER SUPERSERVER 1027GR TRF 1027GR TRFT USER S MANUAL Revision 1 0a...
Страница 6: ...v Preface Notes...
Страница 25: ...2 10 SUPERSERVER 1027GR TRF 1027GR TRFT User s Manual Notes...
Страница 29: ...3 4 SUPERSERVER 1027GR TRF 1027GR TRFT User s Manual Notes...
Страница 61: ...5 28 SUPERSERVER 1027GR TRF 1027GR TRFT User s Manual Notes...
Страница 71: ...6 10 SUPERSERVER 1027GR TRF 1027GR TRFT Series User s Manual Notes...
Страница 105: ...A 2 SUPERSERVER 1027GR TRF 1027GR TRFT User s Manual Notes...
Страница 109: ...B 4 SUPERSERVER 1027GR TRF 1027GR TRFT Series User s Manual Notes...