ERVER 5018A-MLTN4 User's Manual
Warning:
do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Installing the Outer Rails to the Rack
Installing the Outer Rails
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
fits snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
Use a washer with each screw.
4. Repeat steps 1-4 for the left outer rail.
Figure 2-3. Assembling the Outer Rails
Secure to the
Front of the Rack
Secure to the
Rear of the Rack
Attach Outer Rack Rails
Together