5-15
Chapter 5: Chassis Setup
Replacing the Power Distributor
Redundant server chassis that are 2U in height or higher, require a power distribu-
tor. The power distributor provides failover and power supply redundancy. In the
unlikely event you must replace the power distributor, do following
Installing the Power Distributor
Power down the server and remove the plug from the wall socket or power
1.
strip.
Remove all cable connections from the power supply to the motherboard,
2.
backplane, and other components. Also, remove both power supplies.
Locate the power distributor between the power supply and the fan row.
3.
Remove the three screws securing the power supply.
4.
Gently pull the power distributor from the chassis. Make the guide all the
5.
cables through the power distributor housing.
Slide the new power distributor module into the power distributor housing.
6.
Make that you slide the cables through the bottom of the housing.
Reconnect all the power cables, replace the power supply, and insert the plug
7.
into the wall.
Figure 5-11: Removing the Power Distributor