Chapter 4: BIOS
4-17
Hardware Monitor Logic (*See the Note on Page 4-16.)
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The hardcode default setting is
75
o
C
. (*See the note below.)
CPU1 Temperature
Temperature Monitoring (*Available if supported by the CPU)
Highlight this and hit <Enter> to see monitor data for the following PECI (Platform
Environment Control Interface) items:
PECI Agent 1 Temperature/PECI Agent 2 Temperature
/
PECI Agent 3 Temperature/
PECI Agent 4 Temperature
System Temperature
Fan1-Fan5 Speeds
: If the feature of Auto Fan Control is enabled, the BIOS will
automatically display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vice versa.
If the option is set to 3-pin fan, the fan speed is controlled by voltage. If the option
is set to 4-pin, the fan speed will be controlled by Pulse Width Modulation (PWM).
Select 3-pin if your chassis came with 3-pin fan headers. Select 4-pin if your chas-
sis came with 4-pin fan headers. Select Workstation if your system is used as a
Workstation. Select Server if your system is used as a Server. Select Disable to
disable fan speed control and allow the onboard fans to constantly run at full speed
(12V). The Options are:
1. Disable
, 2. 3-pin (Server), 3. 3-pin (Workstation), 4.
4-pin (Server) and 5. 4-pin (Workstation).
Voltage Monitoring
The following items will be monitored and displayed:
Vcore A, 1.5V, -12V, Vdimm, +3.3V, +12V, 5Vsb, 5VDD, P_VTT, Vbat
*Note:
In the Windows OS environment, the Supero Doctor III settings take pre-
cedence over the BIOS settings. When first installed, Supero Doctor III adopts the
temperature threshold settings previously set in the BIOS. Any subsequent changes
to these thresholds must be made within Supero Doctor, since the SD III settings
override the BIOS settings. For the Windows OS to adopt the BIOS temperature
threshold settings, please change the SDIII settings to be the same as those set
in the BIOS.