2-8
S
UPER
S
ERVER 5037MR-H8TRF User's Manual
Figure 2-6. Installing the Chassis into a Rack
Standard Chassis Installation
1. Con
fi
rm that the inner rails are properly installed on the chassis.
2. Con
fi
rm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure
even on both sides, until the locking tab of the inner rail clicks into the front of
the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis
all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.
Ball-Bearing
Shuttle
Содержание 5037MR
Страница 1: ...SUPER SUPERSERVER Super MicrocloudTM 5037MR H8TRF USER S MANUAL Revision 1 0 ...
Страница 5: ...v Preface Notes ...
Страница 14: ...1 6 SUPERSERVER 5037MR H8TRF User s Manual Notes ...
Страница 56: ...5 22 SUPERSERVER 5037MR H8TRF User s Manual Notes ...
Страница 72: ...6 16 SUPERSERVER 5037MR H8TRF User s Manual Notes ...
Страница 100: ...4 28 SUPERSERVER 5037MR H8TRF User s Manual Notes ...
Страница 102: ...A 2 SUPERSERVER 5037MR H8TRF User s Manual Notes ...
Страница 105: ...B 3 Appendix B System Specifications ...