Chapter 2: Installation
2-25
Pin Number
Function
1
GND
3
GND
5
Key
7
GND
9
GND
11
GND
13
GND
15
GND
17
GND
19
GND
21
GND
23
GND
25
GND
27
GND
29
GND
31
GND
33
GND
Pin Number
Function
2
FDHDIN
4
Reserved
6
FDEDIN
8
Index-
10
Motor Enable
12
Drive Select B-
14
Drive Select A-
16
Motor Enable
18
DIR-
20
STEP-
22
W rite Data-
24
W rite Gate-
26
Track 00-
28
W rite Protect-
30
Read Data-
32
Side 1 Select-
34
Diskette
Floppy Connector Pin Definitions (JP12)
Floppy Connector
The floppy connector is located
on J12. See the table below for
pin definitions.
2-8
Floppy/Hard Disk Drive, IPMI, IDE and SCSI
Connections
Note the following when connecting the floppy and hard disk drive cables:
•
The floppy disk drive cable has seven twisted wires.
•
A red mark on a wire typically designates the location of pin 1.
•
A single floppy disk drive ribbon cable has 34 wires and two connectors to
provide for two floppy disk drives. The connector with twisted wires always
connects to drive A, and the connector that does not have twisted wires
always connects to drive B.
K B
DIMM 4B
M
o
u
s
e
U
S
B
0/1
J 1 4
C
O
M
1
DIMM 4A
DIMM 3B
DIMM 3A
DIMM 2B
DIMM 2A
DIMM 1B
DIMM 1A
GLAN1
GLAN2
V
G
A
S
C
S
I C
h
B
Battery
JPG1(VGA Enable)
JPL1(LAN Enable)
RAGE-
X
GLAN
C T R L
P X H
P X H
PCI-X
PCI-X
E 7 5 2 0
(North Bridge)
ICH5R
( S o u t h
Bridge)
Z C R
IPMI 2.0
BIOS
S I/O
7 9 0 2
S C S I
C T R L
IDE #1
IDE #2
Floppy
SCSI Ch A
W O L
C
O
M
2
Fan3
S C S I
E n a b l e
F P U S B 0 / 1
J D 2
J P 9
CLR CMOS
Force PW-On
W O R
S P K
S W
S
C
S
I
Ter. A
JPA1
JBT1
S
M
B
F
A
N
5
S
A
T
A
1
S
A
T
A
0
F
P
C
T
R
L
J
F
1
F A N 2
F A N 1
2 0 - P i n P W
8-Pin
C P U
4-Pin
P W
PW SMB
P W
L E D
CH
I n t
J L 1
J W D
W D
CPU1
CPU2
JP11
Alarm
S W
JPA3
JPA2
SCSI Ter. B
OH
J 3 3
J 3 4
J 1 6
L
G
5
J14
J D 1
J A 1
J 5
J 6
J 1 2
F
A
N
4
Firmware
H u b
J1B1
J1D1
J 3 8
J 3 2
J
4
F
4
J
4
F
5
M
e
m
o
ry
S
p
e
e
d
(*N
o
te
:4
)
J
1
1
P W
F a i l
JP10
S P K R
IPMI 2.0
BIOS
S I/O
7 9 0 2
S C S I
C T R L
IDE #1
IDE #2
Floppy
SCSI Ch A
W O L
COM2
Fan3
e
Force PW-On
W O R
S P K
S W
SCSI
Ter. A
JPA1
SM
B
FAN5
SATA1
SATA0
P W
L E D
CH
I n t
J L 1
J W D
W D
CPU2
JP11
Alarm
S W
JPA3
JPA2
SCSI Ter. B
OH
J D 1
J A 1
J 5
J 6
J 1 2
FAN4
Firmware
H u b
J11
JP10
Floppy
Содержание X6DHR-X8G
Страница 1: ... X6DHR X8G X6DHR XiG USER S MANUAL Revision 1 0 SUPER ...
Страница 9: ...Chapter 1 Introduction 1 3 Introduction Figure 1 1 X6DHR X8G X6DHR XiG Image ...
Страница 54: ...3 6 X6DHR X8G X6DHR XiG User s Manual Notes ...
Страница 73: ...Chapter 4 BIOS 4 19 N12V P12V VDD P5Vsb15 ...
Страница 84: ...A 6 X6DHR X8G X6DHR XiG User s Manual Notes ...
Страница 90: ...B 6 X6DHR X8G X6DHR XiG User s Manual Notes ...