Chapter 2: Installation
2-27
Signal Names
+D B(12)
+D B(13)
+D B(14)
+D B(15)
+D B(P1)
+DB(0)
+DB(1)
+DB(2)
+DB(3)
+DB(4)
+DB(5)
+DB(6)
+DB(7)
+DB(P)
GR OUND
DIF FSENS
TER MPW R
TER MPW R
RESERVED
GR OUND
+ATN
GR OUND
+BSY
+ACK
+RST
+MSG
+SEL
+C/D
+REQ
+I/O
+DB(8)
+DB(9)
+D B(10)
+D B(11)
Connector
Contact
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Signal Names
-DB(12)
-DB(13)
-DB(14)
-DB(15)
-DB(P1)
-DB(0)
-DB(1)
-DB(2)
-DB(3)
-DB(4)
-DB(5)
-DB(6)
-DB(7)
-DB(P)
GROUND
GROUND
TERMPW R
TERMPW R
RESERVED
GROUND
-ATN
GROUND
-BSY
-ACK
-RST
-MSG
-SEL
-C/D
-REQ
-I/O
-DB(8)
-DB(9)
-DB(10)
-DB(11)
Connector
Contact
Number
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
68-pin Ultra320 SCSI C onnectors (JA1 and JA2)
Ultra320 SCSI Connectors
(*X6DHR-X8G Only)
Refer to the table below for the pin
definitions of the Ultra320 SCSI
connectors located at JA1 and JA2.
K B
DIMM 4B
M
o
u
s
e
U
S
B
0
/1
J 1 4
C
O
M
1
DIMM 4A
DIMM 3B
DIMM 3A
DIMM 2B
DIMM 2A
DIMM 1B
DIMM 1A
GLAN1
GLAN2
V
G
A
S
C
S
I C
h B
Battery
JPG1(VGA Enable)
JPL1(LAN Enable)
RAGE-
X
G L A N
C T R L
P X H
P X H
PCI-X
PCI-X
E 7 5 2 0
(North Bridge)
ICH5R
( S o u t h
Bridge)
Z C R
IPMI 2.0
BIOS
S I/O
7 9 0 2
S C S I
C T R L
IDE #1
IDE #2
Floppy
SCSI Ch A
W O L
COM2
Fan3
S C S I
E n a b l e
F P U S B 0 / 1
J D 2
J P 9
CLR CMOS
Force PW-On
W O R
S P K
S W
S
C
S
I
T
e
r.
A
JPA1
JBT1
S
M
B
F
A
N
5
S
A
T
A
1
S
A
T
A
0
F
P
C
T
R
L
J
F
1
F A N 2
F A N 1
2 0 - P i n P W
8-Pin
C P U
4-Pin
P W
P W S M B
P W
L E D
CH
I n t
J L 1
J W D
W D
CPU1
CPU2
JP11
Alarm
S W
JPA3
JPA2
SCSI Ter. B
OH
J 3 3
J 3 4
J 1 6
LG5
J14
J D 1
J A 1
J 5
J 6
J 1 2
F
A
N
4
Firmware
H u b
J1B1
J1D1
J 3 8
J 3 2
J
4
F
4
J
4
F
5
M
e
m
o
ry
S
p
e
e
d
(*N
o
te
:4
)
J
1
1
P W
F a i l
JP10
S P K R
VGA
SCSI Ch B
Battery
JPG1(VGA Enable)
JPL1(LAN Enable)
RAGE-
X
G L A N
C T R L
P X H
P X H
ICH5R
( S o u t h
Bridge)
Z C R
S I/O
7 9 0 2
S C S I
C T R L
SCSI Ch A
W O L
C
O
M
2
Fan3
S C S I
E n a b l e
F P U S B 0 / 1
J D 2
CLR CMOS
Force PW-On
W O R
S P K
S W
SCSI
Ter. A
JPA1
JBT1
P W
L E D
CH
I n t
J L 1
J W D
W D
JP11
Alarm
S W
JPA3
JPA2
SCSI Ter. B
OH
LG
5
J14
J D 1
J A 1
J 5
J 6
J 1 2
Firmware
H u b
JP10
S P K R
SCSI Ch A
SCSI Ch B
Содержание X6DHR-X8G
Страница 1: ... X6DHR X8G X6DHR XiG USER S MANUAL Revision 1 0 SUPER ...
Страница 9: ...Chapter 1 Introduction 1 3 Introduction Figure 1 1 X6DHR X8G X6DHR XiG Image ...
Страница 54: ...3 6 X6DHR X8G X6DHR XiG User s Manual Notes ...
Страница 73: ...Chapter 4 BIOS 4 19 N12V P12V VDD P5Vsb15 ...
Страница 84: ...A 6 X6DHR X8G X6DHR XiG User s Manual Notes ...
Страница 90: ...B 6 X6DHR X8G X6DHR XiG User s Manual Notes ...