56
Super X12DAi-N6 User's Manual
1
2
3
Power Button
(Blue LED_Cathode_UID)
NIC1 (Activity) LED
Reset Button
HDD LED
FP PWR LED
ID_UID/3.3V Stby
Ground
19
Ground
20
1
2
Ground
Power Fail (for LED6)
NIC2 (Link) LED
NMI
3.3V
(Red OH/Fan Fail/PWR Fail for LED5/Blue UID LED)
3.3V
JF1
Red+
Blue+
NIC2 (Activity) LED
NIC1 (Link) LED
Key
Key
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN Port 1 is located on pins 11
and 12 of JF1, and LAN Port 2 is on pins 9 and 10. Refer to the tables below for pin definitions.
LAN1/LAN2 LED
Pin Definitions (JF1)
Pin# Definition
Pin# Definition
9
NIC 2 Activity LED
10
NIC 2 Link LED
11
NIC 1 Activity LED
12
NIC 1 Link LED
ID_UID Switch/HDD LED
The UID switch/HDD LED connection is located on pins 13 and 14 of JF1. The UID switch
is used for a chassis that supports a front UID switch. The front UID switch functions in the
same way as the rear UID switch; both are for input only and cannot be used for output.
When this LED is blinking green, it indicates HDD is active. Attach a cable to pins 13 and 14
to show ID_UID status and hard drive activity. Refer to the tables below for pin definitions.
ID_UID/HDD LED
Pin Definitions (JF1)
Pins
Definition
13
ID_UID/3.3V Stdby
14
HDD Activity
ID_UID/HDD LED
LED State
Color
State
Blinking Green
HDD Active
LAN1/LAN2 LED
LED States
Color
State
NIC 2: Blinking green
LAN 2: Active
NIC 1: Blinking green
LAN 1: Active
1. NIC2 (LAN 2) LED
2. NIC1 (LAN 1) LED
3. ID_UID/HDD LED
Содержание X12DAi-N6
Страница 1: ...USER S MANUAL Revision 1 0b X12DAi N6...
Страница 23: ...23 Chapter 2 Installation Cutout CPU Key Pin 1 Processor Top View 1 The 3rd Gen Intel Xeon Scalable Processor...
Страница 144: ...Super X12DAi N6 User s Manual 144 Driver Health This feature displays the following driver health information...