background image

USER’S MANUAL

 

 

Revision 1.1a

X10QBi Platform

with

X10QBi Baseboard

AOM-X10QBi-A/L I/O Module

X 1 0 Q B i - M E M 1 / M E M 2 

Memory Card

Содержание x10qbi

Страница 1: ...USER S MANUAL Revision 1 1a X10QBi Platform with X10QBi Baseboard AOM X10QBi A L I O Module X1 0 Q B i M E M 1 M E M 2 Memory Card...

Страница 2: ...UCH DAMAGES IN PARTICULAR SUPER MICRO COMPUTER INC SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INS...

Страница 3: ...is intended to be installed and serviced by professional technicians DDR4 ECC 1866 MHz max RDIMM LRDIMM memory modules are supported when the X10QBi MEM2 card is used in the system and DDR3 ECC 1600 M...

Страница 4: ...nstal lation and to avoid damage done to the system or injury to yourself Warning Important information given to ensure proper system installation or to prevent damage to the components Note Additiona...

Страница 5: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...

Страница 6: ...Board 2 5 Installing a Passive CPU Heatsink 2 9 Removing the Heatsink 2 10 2 4 I O Module and Memory Card Installation 2 11 Installing the AOM X10QBi A L I O Module on the Mainboard 2 11 2 5 Installi...

Страница 7: ...3 Universal Serial Bus USB On the Main Board 2 34 2 9 Jumper Settings 2 35 Explanation of Jumpers 2 35 LAN Enable Disable On the I O Module 2 35 BMC Enable On the I O Module 2 36 VGA Enable On the I O...

Страница 8: ...ve Exit 4 35 Appendix A BIOS POST Error Beep Codes A 1 BIOS POST Error Beep Codes A 1 Appendix B Software Installation Instructions B 1 Installing Software Programs B 1 B 2 Configuring SuperDoctor III...

Страница 9: ...ard is intended to be used in conjunction with the AOM X10QBi A L I O module and the X10QBi MEM1 or X10QBi MEM2 the memory card as an integrated server platform It is not to be used as a stand alone p...

Страница 10: ...1B Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publishing this manual The components installed in your system may or may not look exactly th...

Страница 11: ...JPME1 JWD1 JPT1 JWP1 JXDP3 JXDP2 JVRM_I2C1 JVRM_I2C2 JXDP1 JIPMB1 JPI2C1 JD1 T SGPIO1 T SGPIO2 I SATA0 I SATA1 I SATA2 I SATA5 I SATA4 I SATA3 JF1 JIO1 SMI SLOT P4M1 SMI SLOT P3M2 SMI SLOT P3M1 SMI S...

Страница 12: ...ed Disabled Pins 1 2 Enabled JPG1 3 VGA Enabled Disabled Pins 1 2 Enabled AOM X10QBi A L I O LED Indicator LED Loca tion Description State LED28 4 UID LED JEDUID1 Blue Unit Identified AOM X10QBi A L I...

Страница 13: ...10 PCI E 3 0 X8 CPU4 SLOT11 PCI E 3 0 X16 CPU3 SLOT7 PCI E 3 0 X8 CPU3 SLOT6 PCI E 3 0 X8 CPU3 SLOT9 PCI E 3 0 X16 CPU2 SLOT5 PCI E 3 0 X8 CPU2 SLOT3 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT1 P...

Страница 14: ...MMD1 DIMM C3 C2 DIMM C2 DIMM C1 DIMM D3 DIMM D2 DIMM D1 DIMM A3 DIMM A2 DIMM A1 DIMM B3 DIMM B2 DIMM B1 A1 A2 A3 B1 B2 B3 C1 C3 D1 D3 C2 D2 DIMM A3 DIMM A2 DIMM A1 DIMM B3 DIMM B2 DIMM B1 DIMM C3 DIMM...

Страница 15: ...DIMM A3 DIMM A2 DIMM A1 DIMM B3 DIMM B2 DIMM B1 A1 A2 A3 B1 B2 B3 C1 C3 D1 D3 C2 D2 DIMM A3 DIMM A2 DIMM A1 DIMM B3 DIMM B2 DIMM B1 DIMM C3 DIMM C2 DIMM C1 DIMM D3 DIMM D2 DIMM D1 Memory Buffer CTRL X...

Страница 16: ...B1 B2 B3 A1 A2 DIMMC3 DIMMA1 DIMMA2 DIMMA3 DIMMB3 DIMMB2 DIMMB1 Rev 1 01 DIMMC2 DIMMC1 DIMMD3 DIMMD2 DIMMD1 Memory Buffer Controller Memory Buffer Controller X10QBi MEM2 Rev 1 01 Memory Card Layout A...

Страница 17: ...NT_LED1 DIMM2A_LED3 DIMM1A_LED2 DIMM0A_LED1 DIMM2B_LED6 DIMM1B_LED5 DIMM0B_LED4 DIMM2C_LED1 DIMM1C_LED8 DIMM0C_LED7 DIMM2D_LED4 DIMM1D_LED3 DIMM0D_LED2 BAR CODE A3 D1 D2 C1 C2 C3 D3 OK B1 B2 B3 A1 A2...

Страница 18: ...8 PCI E 3 0 X8 CPU4 SLOT10 PCI E 3 0 X8 CPU4 SLOT11 PCI E 3 0 X16 CPU3 SLOT7 PCI E 3 0 X8 CPU3 SLOT6 PCI E 3 0 X8 CPU3 SLOT9 PCI E 3 0 X16 CPU2 SLOT5 PCI E 3 0 X8 CPU2 SLOT3 PCI E 3 0 X8 CPU1 SLOT2 PC...

Страница 19: ...4 pin System Cooling Fan Headers FAN1 FAN10 BT2 Onboard Battery See Chpt 3 for Battery Disposal COM1 on the baseboard Serial COM Port Header 1 on the X10QBi base board COM2 on the I O module Serial CO...

Страница 20: ...r the system and to provide adequate power to the components be sure to connect the 24 pin power connector and all 8 pin T SGPIO 1 2 Serial_Link General Purpose I O Headers USB0 1 USB2 3 USB6 7 Front...

Страница 21: ...upports up to 12 modules of DDR3 ECC RDIMM LRDIMM memory with speeds of up to 1600 MHz 3 Each X10QBi MEM2 memory card supports up to 12 modules of DDR4 ECC RDIMM LRDIMM memory with speeds of up to 186...

Страница 22: ...PMI 2 0 supported by the AST2400 BMC Serial COM Port One 1 Fast UART 16550 Connection on the AOM X10QBi A L I O module for backpanel support One Front Accessible Serial Header located on the X10QBi sy...

Страница 23: ...Monitor 2 TM2 support Fan Control Ten 10 4 pin system cooling fans with fan status monitoring with firmware Pulse Width Modulation fan speed control and low noise fan speed control System Man agement...

Страница 24: ...CPU4_S3 PCIE G3x16 in X16slot LPC SMBus USB PCIE x1 X4 DMI2 PCIE G3x32 LANEs PCIE G3x32 LANEs PCIE G3x32 LANEs PCIE G3x24 LANEs PCIE G3x8 LANEs QPI 9 6 GT s QPI 9 6 GT s QPI 9 6 GT s QPI 9 6 GT s QPI...

Страница 25: ...an also be config ured as x8 x4 and x2 links to comply with the PCI E Base Specification Rev 2 0 These PCI E Gen 3 lanes support peer to peer read and write transactions The 602J PCH also offers a wid...

Страница 26: ...he screen The user can adjust the voltage thresholds to define the sensitivity of the voltage monitor Fan Status Monitor with Firmware Control PC health monitoring in the BIOS can check the RPM status...

Страница 27: ...ve high CPU clock rates The X10QBi system motherboard includes a 24 pin ATX main system power con nector JWP1 six 8 pin power connectors JWP2 JPW7 and a SATA DOM power connector JWF1 Please connect th...

Страница 28: ...ystem with real time thermal control and power management for maximum energy efficiency Although IPNM Specification Version 1 5 20 is supported by the BMC Baseboard Management Controller your system m...

Страница 29: ...onents Read this section in its entirety before installing or configuring components in the Supermicro chassis Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr E...

Страница 30: ...losi n si la bater a se reemplaza de manera incorrecta Re emplazar la bater a exclusivamente con el mismo tipo o el equivalente recomen dado por el fabricante Desechar las bater as gastadas seg n las...

Страница 31: ...dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y regla mentos nacionales Attention L...

Страница 32: ...ips or modules avoid touching their pins Put the system motherboard and peripherals back into their antistatic bags when not in use For grounding purposes make sure that your system chassis provides e...

Страница 33: ...1 01B MAC CODE BAR CODE M M M M M M FAN5 FAN10 FAN7 FAN6 FAN8 FAN9 FAN1 FAN4 FAN2 FAN3 JPW2 JPW3 LED_PORT80 JM2 JM5 JLPC1 JP2 BT2 SP1 JP3 JL1 J17 JOH1 JI2C2 LED28 LED23 LED2 LED1 LED15 LED19 LED22 LED...

Страница 34: ...d gently push down on the lever labelled Open 1st to open the load plate Lift the load plate to open it completely OPEN1st OPEN1st 1 2 Press down on Load Lever Close 1st OPEN1st 1 Pull lever away from...

Страница 35: ...not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Socket K...

Страница 36: ...d plate with the CPU inside the socket Lock the lever labeled Close 1st first then lock the lever labeled Open 1st second Using your thumb gently push the load levers down to the lever locks OPEN1st O...

Страница 37: ...sink on top of the CPU so that the four mounting holes are aligned with those on the motherboard and the underlying heatsink bracket 3 Screw in two diagonal screws the 1 and 2 screws in the figure bel...

Страница 38: ...motherboard in the sequence as shown in the figure below 2 Gently wiggle the heatsink to loosen it from the CPU Do not use excessive force 3 Once the CPU is loosened remove the CPU from the CPU socket...

Страница 39: ...g installed on the motherboard your system cannot be turned on AOM X10QBi A L I O Module SIO Slot 2 4 I O Module and Memory Card Installation D A C B E G F I O Port Locations and Definitions A VGA1 VG...

Страница 40: ...Push the release tabs outwards on both ends of the DIMM slot to unlock it 3 Align the key of the DIMM module with the receptive point on the memory slot 4 Align the notches on both ends of the module...

Страница 41: ...QBi baseboard 3 To fully utilize all onboard 11 PCI E slots for the use of full length add on cards please install four DIMM modules in slots P1M2 P2M1 P3M2 P4M1 and reserve slots P1M1 and P4M2 See be...

Страница 42: ...les from the memory card To remove memory cards from the baseboard follow the reverse sequence of memory card installation as shown on the memory population table on the previous page Removing RDIMM L...

Страница 43: ...PU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M MAC CODE JPW1 CPU2 SLOT4 PCI E 3 0 X16 USB5 JVRMCPU1 A 4 J...

Страница 44: ...eboard the X10QBi supports up to 96 modules with a total size of 6TB supported 4 When installing a DIMM module on a memory card be sure to press the module straight down into the slot until it is prop...

Страница 45: ...1066 N A RDIMM DRx4 8GB 16GB 1600 1333 1600 1333 1333 1333 1333 1066 1066 N A RDIMM QRx4 16GB 32GB 1066 1066 1066 1066 1066 1066 N A N A N A N A LRDIMM QRx4 16GB 32GB 1600 1333 1600 1333 1600 1333 16...

Страница 46: ...1066 1066 N A RDIMM DRx4 8GB 16GB 1600 1333 1600 1333 1333 1333 1333 1066 1066 N A RDIMM QRx4 16GB 32GB 1066 1066 1066 1066 1066 1066 N A N A N A N A LRDIMM QRx4 16GB 32GB 1600 1333 1600 1333 1600 133...

Страница 47: ...M 3DS is POR for BDW EX 2 Intel completed margin collection successfully 3 LRDIMM enabling completed successfully HSW EX BDW EX 2 1 DDR4 RDIMM LRDIMM 1 Type Ranks Per DIMM and Data Width x8 is support...

Страница 48: ...he baseboard your system cannot be turned on SW1 LED28 JPB1 JPG1 JPL1 AOM X10QBi A L Rev 1 02 SWUID1 JEDUID1 COM2 IPMI_LAN LAN2 LAN1 VGA1 VGA2 LAN CTRL BMC AOM X10QBi A L I O Module SIO Slot D A C B E...

Страница 49: ...I O module Refer to the baseboard layout below for the location A COM1 B COM2 C VGA1 D VGA2 Serial Ports COM1 On the Baseboard COM2 On the I O Module A COM port header COM1 is located on the X10QBi b...

Страница 50: ...e refer to Section 2 11 for LAN LED information 2 USB connections are located on the X10QBi base board LAN Ports Pin Definition Pin Definition 1 TRCT2 13 IETCT 2 TRD2 14 IET 3 TRD2 15 IET 4 TRD3 16 N...

Страница 51: ...ront panel UID LED is located at pins 7 8 of the Front Control Panel at JF1 Connect a cable to pins 7 8 on JF1 for front panel UID LED indication When you press the UID switch both rear UID LED and fr...

Страница 52: ...JXDP3 JXDP2 JVRM_I2C1 JVRM_I2C2 JXDP1 JIPMB1 JPI2C1 JD1 T SGPIO1 T SGPIO2 I SATA0 I SATA1 I SATA2 I SATA5 I SATA4 I SATA3 JF1 JIO1 SMI SLOT P4M1 SMI SLOT P3M2 SMI SLOT P3M1 SMI SLOT P2M2 SMI SLOT P2M1...

Страница 53: ...E 3 0 X8 CPU2 SLOT3 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M...

Страница 54: ...tivity LED 10 NIC 2 Link LED 11 NIC 1 Activity LED 12 NIC 1 Link LED A B X10QBi Rev 1 01B MAC CODE BAR CODE M M M M M M FAN5 FAN10 FAN7 FAN6 FAN8 FAN9 FAN1 FAN4 FAN2 FAN3 JPW2 JPW3 LED_PORT80 JM2 JM5...

Страница 55: ...U3 SLOT9 PCI E 3 0 X16 CPU2 SLOT5 PCI E 3 0 X8 CPU2 SLOT3 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN...

Страница 56: ...1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M MAC CODE JPW1 CPU2 SLOT4 PCI E 3 0 X16 USB5 JVRMCPU1 A 4 JVRMCPU2 JVRMCPU3 JVRMCPU4 1 JPW4 JPW5 JPW6 JPW7 Power Button Red OH Fan Fail PWR Fa...

Страница 57: ...q d C JPW3 8 pin PWR Req d D JPW4 8 pin PWR Req d E JPW5 8 pin PWR Req d F JPW6 8 pin PWR Req d G JPW7 8 pin PWR Req d H JSD1 SATA Device PWR Req d for SATA devices A B C D E F G H DOM Power Connector...

Страница 58: ...3 0 X16 CPU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M MAC CODE JPW1 CPU2 SLOT4 PCI E 3 0 X16 USB5 JVRMC...

Страница 59: ...OSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M MAC CODE JPW1 CPU2 SLOT4 PCI E 3 0 X16 USB5 JVRMCPU1 A 4 JVRMCPU2 JVRMCPU3 JVRMCPU4 1 JPW4 J...

Страница 60: ...0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M MAC CODE JPW1 CPU2 SLOT4 PC...

Страница 61: ...SLOT6 PCI E 3 0 X8 CPU3 SLOT9 PCI E 3 0 X16 CPU2 SLOT5 PCI E 3 0 X8 CPU2 SLOT3 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPE...

Страница 62: ...LED23 LED2 LED1 LED15 LED19 LED22 LED18 JBT1 LED35 LED10 LED9 LED8 LED14 LED7 LED12 LED13 LED11 LEDIO1 LED3 JSD1 JP1 JP5 JPME2 JPME1 JWD1 JPT1 JWP1 JXDP3 JXDP2 JVRM_I2C1 JVRM_I2C2 JXDP1 JIPMB1 JPI2C1...

Страница 63: ...identified with a square solder pad on the printed circuit board See the system board layout pages for jumper locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper...

Страница 64: ...fer to the table on the right for jumper settings BMC Enable Jumper Settings Jumper Setting Definition Pins 1 2 BMC Enable Default Pins 2 3 Disabled VGA Enable On the I O Module Jumper JPG1 allows the...

Страница 65: ...LOT4 PCI E 3 0 X16 USB5 JVRMCPU1 A 4 JVRMCPU2 JVRMCPU3 JVRMCPU4 1 JPW4 JPW5 JPW6 JPW7 CMOS Clear JBT1 is used to clear the CMOS Instead of pins this jumper consists of contact pads to prevent the acci...

Страница 66: ...OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M MAC CODE JPW1 CPU2 SLOT4 PCI E 3 0 X16 USB5 JVRMCPU1 A 4 JVRMCPU2 JVRMCPU3 JVRMCPU4 1 JPW4 JPW5 JPW6...

Страница 67: ...MAC CODE BAR CODE M M M M M M FAN5 FAN10 FAN7 FAN6 FAN8 FAN9 FAN1 FAN4 FAN2 FAN3 JPW2 JPW3 LED_PORT80 JM2 JM5 JLPC1 JP2 BT2 SP1 JP3 JL1 J17 JOH1 JI2C2 LED28 LED23 LED2 LED1 LED15 LED19 LED22 LED18 JBT...

Страница 68: ...models only A B LAN LEDs On the I O Module Two LAN ports LAN 1 LAN 2 are located on the I O module of the system Each Eth ernet LAN port has two LEDs The green LED indicates activity while the other L...

Страница 69: ...E 3 0 X8 CPU2 SLOT3 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT1 PCI E 3 0 X8 SIO SLOT CLOSE 1st OPEN 1st CPU2 USB0 1 JI2C1 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st M M M M M M M M...

Страница 70: ...2 42 X10QBi Platform User s Manual Notes...

Страница 71: ...nect all ribbon wire cables from the system board I O module and memory cards including those for internet and USB connections 3 Remove all I O module and add on cards 4 Install the AOM X10QBi A L I O...

Страница 72: ...settings by unplugging the power cord and contracting both pads on the CMOS Clear Jumper JBT1 Refer to the jumper section in Chapter 2 2 Remove all components from the system board I O module and memo...

Страница 73: ...ly seated in their slots Follow the instructions given in the Memory section in Chapter 2 6 Please follow the instructions given in the DIMM population tables listed in the Memory section in Chapter 2...

Страница 74: ...dentify the trouble areas Refer to the steps listed in Section A above for proper troubleshooting procedures 4 Identifying bad components by isolating them If necessary remove the com ponent in questi...

Страница 75: ...ee the FAQs on our website http www supermicro com before contacting Technical Support 2 BIOS upgrades can be downloaded from our website http www supermicro com 3 If you still cannot resolve the prob...

Страница 76: ...ng You can choose from the zip file or the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the format AMI bat filename rom from...

Страница 77: ...with the date of purchase is required before any warranty service will be rendered You can obtain service by calling your vendor for a Returned Merchandise Authorization RMA number When returning to...

Страница 78: ...3 8 X10QBi Platform User s Manual Notes...

Страница 79: ...the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserv...

Страница 80: ...From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the...

Страница 81: ...ween fields The date must be entered in Day MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10QBi V...

Страница 82: ...POST messages The options are Disabled and Enabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting Sele...

Страница 83: ...sses the power button for 4 seconds or longer The options are Instant Off and 4 Seconds Override Restore on AC Power Loss Use this item to set the power state after a power outage Select Stay Off for...

Страница 84: ...er 0 to enable all cores There are 10 cores available in the system The default setting is 0 Performance Watt Select Power Optimized to enable Intel Turbo Boost Technology support when the Power Perfo...

Страница 85: ...ry to the L2 cache to improve CPU performance The options are Enable and Disable Adjacent Cache Prefetch Available when supported by the CPU Select Enable for the CPU to prefetch both cache lines for...

Страница 86: ...the option is set to Custom the following items will display CPU P State Control Available when Power Technology is set to Custom EIST P states EIST Enhanced Intel SpeedStep Technology allows the syst...

Страница 87: ...Power Technology is set to Custom Select Enable to allow the BIOS to report the CPU C6 state ACPI C3 to the operating system During the CPU C6 state power to all cache is turned off The options are D...

Страница 88: ...work load condition The options are Balanced recommended and I O sensitive Chipset Configuration North Bridge This feature is used to configure Intel North Bridge settings Integrated IO Configuration...

Страница 89: ...CPU2 Slot4 x16 CPU2 Slot5 x8 CPU2 Slot3 x8 Use the items below to configure the PCI E settings for a PCI E port specified by the user The following items will display PCI E Port Link Status PCI E Port...

Страница 90: ...k Speed Link Speed Use this item to select the PCI E link speed for the PCI E port specified by the user The options are Auto GEN1 2 5 GT s GEN2 5 GT s and GEN3 8 GT s IOAT Configuration Enable IOAT S...

Страница 91: ...to enhance system performance The options are Enable and Disable PCI Express Global Options Power Down Unused Ports Select Enable to power down the ports that are conneced The options are Disable Ena...

Страница 92: ...se this feature to set the IO resource allocation ratio from 0 8 The default setting is 1 MMIOL Resource Allocation Ratio Use this feature to set the Memory Mapped IO resource allocation ratio from 0...

Страница 93: ...Enabled VMSE Lockstep Mode Select Enabled to support the VMSE Lockstep mode which will support Lock step mode for the Intel Scalable Memory Interconnect 2 Intel SMI 2 controller The options are 1 1 M...

Страница 94: ...feature to set the Low Bit value for the Leaky Bucket algorithm which is used to check the data transmissions between CPU sockets and the memory controller The default setting is 40 Leaky Bucket High...

Страница 95: ...ice Tagging Select Enable to support device tagging The options are Disable and Enable A7 Mode Select Enabled to support A7 Addressing Mode to improve memory performance The options are Disable and En...

Страница 96: ...he options are Disabled and Enabled SATA Configuration When this submenu is selected the AMI BIOS automatically detects the presence of SATA devices and displays the following items SATA Controller Th...

Страница 97: ...register snooping which will allow the PCI cards that do not contain their own VGA color palette to examine the video cards palette and mimic it for proper color display The options are Disabled and E...

Страница 98: ...ry address mapping for the PCH The options are 32G 64G 128G 256G 512G and 1024G Resource Auto Adjust When this item is set to Enable the PCI resource requests for each CPU socket will be automatically...

Страница 99: ...WHEA plat form and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monito...

Страница 100: ...Status This item displays the status of TPM Support to indicate if TPM is currently ac tive or not activated TPM Owner Status This item displays the status of TPM Ownership TXT Support Select Enabled...

Страница 101: ...12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ IRQ 3 4 5 6 7 10 11 12 Serial Port 2 Configuration Serial Port Select Enabled to enable a serial port specified by the user...

Страница 102: ...ange data with the client computer which is the remote computer used by the user Terminal Type Use this feature to select the target terminal emulation type for Console Redirec tion Select VT100 to us...

Страница 103: ...sole Redirection to prevent data loss caused by buffer overflowing Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receivin...

Страница 104: ...ort The feature selects a serial port used by the Microsoft Windows Emergency Management Services EMS to communicate with a remote server The options are COM1 Console Redirection and COM2 SOL Console...

Страница 105: ...atures is displayed Data Bits Parity Stop Bits iSCSI Configuration This item displays iSCSI configuration information iSCSI Initiator Name This item displays the name of the iSCSI Initiator which is a...

Страница 106: ...led Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled Erasing Settings Erase Event Log Select Yes to erase all error events in the SMBI...

Страница 107: ...TW Multiple Event Count Time Window This item is used to determine how long in minutes the multiple event counter should wait before generating a new event log Enter a number between 0 to 99 The defau...

Страница 108: ...t Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging support at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next r...

Страница 109: ...is computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dy namic Ho...

Страница 110: ...em to set the administrator password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this item to set a...

Страница 111: ...option prioritizes the order of bootable devices that the system to boot from Press ENTER on each entry from top to bottom to select devices Boot Option 1 to Boot Option 15 Delete Boot Option Use this...

Страница 112: ...form User s Manual Hard Disk Drive BBS Priorities This item sets the boot sequence of available hard disk drives Boot Option 1 Network Drive BBS Priorities Boot Option 1 UEFI Application Boot Prioriti...

Страница 113: ...ption to quit the BIOS setup without making any changes to the system configuration Select Discard Changes and Exit and press Enter When the dialog box appears asking you if you want to exit the BIOS...

Страница 114: ...o abandon optimized defaults Save as User Defaults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save va...

Страница 115: ...anufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the correspondi...

Страница 116: ...A 2 X10QBi Platform User s Manual Notes...

Страница 117: ...age driver diskette by booting into a driver CD please set the SATA configuration to Compatible Mode and configure the SATA as an IDE in the BIOS Setup After making the driver diskette be sure to chan...

Страница 118: ...I displays crucial system information such as CPU temperature system voltages and fan status Refer to the figure below for a display of the SuperDoctor III interface Note 1 The default user_name and p...

Страница 119: ...r III Interface Display Screen II Remote Control Note SD III software and the user s manual can be downloaded from our website at http www supermicro com products accessories soft ware SuperDoctorIII...

Страница 120: ...B 4 X10QBi Platform User s Manual Notes...

Страница 121: ...off control to a computer system at bootup C 2 How to Recover the UEFI BIOS Image the Main BIOS Block A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image...

Страница 122: ...because it contains too many folders and files To perform UEFI BIOS recovery using a USB attached device follow the instruc tions below 1 Using a different machine copy the Super ROM binary image file...

Страница 123: ...board until the following screen or a screen similar to the one below displays 4 After locating the new BIOS binary image the system will enter the BIOS Recovery menu as shown below Note At this point...

Страница 124: ...e Do not interrupt this process until BIOS flashing is completed 9 After seeing the message that BIOS update is completed unplug the AC power cable from the power supply to clear the CMOS and then plu...

Страница 125: ...crisis recovery flash used to update the main BIOS block An on call BIOS boot block corruption may occur due to a software tool issue see the image below or an unexpected power outage during BIOS upda...

Страница 126: ...mper JBR1 1 Power down the system 2 Close pins 2 3 on Jumper JBR1 and power on the system 3 Follow the BIOS recovery SOP listed in the previous chapter Appendix C 4 After completing the steps above po...

Страница 127: ...expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in su...

Отзывы: