background image

USER’S MANUAL 

Revision 1.1a

SuperServer

®

SYS-2049U-TR4

Содержание SuperServer SYS-2049U-TR4

Страница 1: ...USER S MANUAL Revision 1 1a SuperServer SYS 2049U TR4 ...

Страница 2: ...lass A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required...

Страница 3: ...rt manuals Product drivers and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support supermicro com This manual may be periodically updated without notice Please check the Supermicro website for possible updates to the manual revision level Secure Data Dele...

Страница 4: ...sing a Setup Location 16 Rack Precautions 16 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 17 Circuit Overloading 18 Reliable Ground 18 2 3 Installing the Rails 19 Identifying the Rails 19 Releasing the Inner Rail 20 Installing the Inner Rails on the Chassis 21 Installing the Outer Rails onto the Rack 22 Sliding the Chassis ont...

Страница 5: ...nstallation 34 ESD Precautions 34 Precautions 34 Introduction to Intel Optane DC Persistent Memory 34 Memory Support 34 Memory Installation Sequence 35 General Memory Population Requirements 36 DIMM Population Guidelines for Optimal Performance 36 4 way Motherboards w Half Memory Configuration Support 37 Memory Population with 48 DIMM Support based on the 82xx 62xx 52xx 42xx Platform 38 DIMM Insta...

Страница 6: ...Installation 70 5 3 SuperDoctor 5 71 5 4 IPMI 71 Chapter 6 UEFI BIOS 6 1 Introduction 72 Starting the Setup Utility 72 6 2 Main Menu 73 6 3 Advanced Settings Menu 74 6 4 Event Logs 102 6 5 IPMI 104 6 6 Security Settings 107 6 7 Boot Settings 110 6 8 Save Exit 113 Appendix A BIOS Error Codes Appendix B Standardized Warning Statements for AC Systems Appendix C System Specifications Appendix D UEFI B...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 39...

Страница 8: ...R1UW E8R 1 Riser Card RSC R2UW 4E8 1 2U Passive Standard Riser Card with two PCIe 3 0 x16 Slots RSC S2 66 2 2U Ultra Riser with 4 GbE ports and 2 PCIe x16 3 0 Intel i350 Add on Card AOC 2UR66 I4G 1 Black gen 3rd hot swap 2 5inch HDD tray MCP 220 00047 0B 24 80x80x38 mm 13 5K RPM hot swap middle cooling fan FAN 0166L4 4 Rail Set quick quick default for 2 3U 17 2 W MCP 290 00053 0N 1 1 2 Unpacking t...

Страница 9: ...ots and onboard controllers Refer to the block diagram on page 15 to determine which slots or devices may be affected Socket Type Socket P0 LGA3647 Memory Integrated memory controller supports up to 12 TB of DDR4 3DS LRDIMM LRDIMM RDIMM ECC 2933 MHz modules in 48 SRAM slots Chipset Intel PCH C621 chipset Expansion Slots Supports up to 11 PCI Express 3 0 expansion cards by means of four riser cards...

Страница 10: ...is used to reboot the system 3 Power LED Indicates power is being supplied to the system power supply This LED should normally be illuminated when the system is operating 4 HDD LED Indicates activity on a hard drive when flashing 5 NIC2 LED Indicates network activity on LAN port 2 when flashing 6 NIC1 LED Indicates network activity on LAN port 1 when flashing 7 Power Fail LED Indicates a power sup...

Страница 11: ... Continuously on and red An overheat condition has occured This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Solid blue Local UID has been activated Use this function to locate the server in a rackmount environment Blinking blue Remote UID is on Use this function to identify the server from a remote location Front Features The CSE 218UTS R1K62P is a 2...

Страница 12: ... is on the left and PS2 is on the right 2 Expansion Slots Up to eleven PCIe expansion cards are supported seven external four internal 3 I O Ports The I O port rear panel is located here See Chapter 4 for details Figure 1 3 Chassis Rear View Rear Features The illustration below shows the features included on the rear of the chassis 1 3 2 1 2 PS1 PS2 ...

Страница 13: ...XB4B USB0 1 CPU1_PORT2 SXB3C CPU1_PORT1 SXB3B VGA UID COM1 I SATA0 3 S SATA0 3 I SATA4 7 USB 4 3 0 USB 2 3 3 0 IPMI_LAN CPU2_PORT2 CPU2_PORT1 CPU1 BACKPLANE POWER GPU POWER P1_DIMMB1 P1_DIMMC1 P1_DIMMB2 P1_DIMMC2 P1_DIMMA1 P1_DIMMA2 WIO 2x16 PCI E 3 0 PCI E 3 0 RSC 56 Lanes PCI E 3 0 RSC 48 Lanes Ultra IO X40 PSU2 PSU1 J12VSB SXB5B SXB5A CPU2_PORT3 CPU3_PORT2 CPU3_PORT3 CPU3_PORT1 CPU4_PORT2 CPU4_...

Страница 14: ...ower header JTPM1 Trusted Platform Module Port 80 connector SXB1A SXB1B SXB1C WIO 2x16 PCIe 3 0 slot for CPU2 Port1 CPU2 Port2 J18 J19 J20 SXB2 WIO x8 PCIe 3 0 slot for CPU2 Port3 SXB3A SXB3B SXB3C Ultra IO x40 slot for CPU1 Port3 CPU1 Port1 CPU1 Port2 J21 J22 J23 SXB4A SXB4B PCIe 3 0 riser card slot with support of 56 lanes for CPU2 Port3 CPU3 Port2 CPU3 Port3 CPU3 Port1 J26 J27 SXB5A SXB5B PCIe ...

Страница 15: ...DIMM UPI UPI1 CPU3 PE1 PE2 PE3 X2 X2 X2 X2 UPI1 UPI0 UPI0 UPI1 UPI1 UP0 CPU1 PE3 x16 CPU1 PE2 x16 CPU1 PE3 x8 2 CPU2 PE1 x16 CPU2 PE2 x16 CPU2 PE3 x8 2 CPU4 PE2 x16 CPU3 PE2 x16 CPU4 PE2 x16 CPU1 PE3 x8 CPU1 PE1 x16 CPU1 PE2 x16 COM JCOM1 CPU2 PE1 x16 HDR 2X5 JUSB1 USB3 0 USB2 0 1 2 3 USB3 0 3 USB2 0 SATA0 gen3 SATA1 gen3 SATA2 gen3 SATA3 gen3 DDR4 DIMM X2 UPI UPI2 UPI2 UPI2 UP2 DDR4 DIMM DDR4 DIM...

Страница 16: ...allation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave enough clearance in front of the rack so that you can open the front door completely 25 inches and approximately 30 inches of clearance in the back of the rack to allow sufficient space for airflow ...

Страница 17: ... in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed to maintain proper cooling Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment ma...

Страница 18: ...attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the ra...

Страница 19: ...des two rail assemblies Each assembly consists of three sections An inner rail that secures directly to the chassis an outer rail that secures to the rack and a middle rail which extends from the outer rail These assemblies are specifically designed for the left and right side of the chassis Warning do not pick up the server with the front handles They are designed to pull the system from a rack o...

Страница 20: ...ut of the rack when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails Releasing Inner Rail from the Outer Rails 1 Pull the inner rail out of the outer rail until it is fully extended as illustrated below 2 Press the locking tab down to release the inner rail 3 Pull the inner rail all the way out 4 Repeat for the other outer...

Страница 21: ...he hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release bracket snaps into place securing the rail to the chassis 4 Optionally you can further secure the inner rail to the chassis with a screw 5 Repeat for the other inner rail Figure 2 3 Installing the Inner Rails Figure 2 4 Inner Rails Installed on...

Страница 22: ...to tip over Figure 2 5 Extending and Mounting the Outer Rails Installing the Outer Rails onto the Rack Installing the Outer Rails 1 Press upward on the locking tab at the rear end of the middle rail 2 Push the middle rail back into the outer rail 3 Hang the hooks on the front of the outer rail onto the square holes on the front of the rack If desired use screws to secure the outer rails to the rac...

Страница 23: ...y recommendations printed on the rails Installing the Chassis into a Rack 1 Extend the outer rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be...

Страница 24: ...m has completely shut down disconnect the AC power cord s from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power supply module s 3 2 Accessing the System The CSE 218UTS R1K62P features a removable top cover which allows easy access to the inside of the chassis Removing the Top...

Страница 25: ...rning Except for short periods of time do not operate the server without the cover in place The chassis cover must be in place to allow for proper airflow and to prevent overheating Figure 3 1 Removing the Chassis Cover Remove Screw Remove Screw 2 2 3 3 4 ...

Страница 26: ... cover is on the CPU socket and none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the LGA lands gold contacts Improper installation or socket misalignment can cause serious damage to the processor or CPU socket which may require manufacturer repairs Thermal grease is pre applied on a new heatsink No additiona...

Страница 27: ...rier Assembly The processor carrier assembly contains the Intel Xeon Non Fabric Non F processor and a processor carrier 1 Plastic Protective Cover 2 CPU Socket 1 Non F Processor 2 Processor Carrier Overview of the CPU Socket The CPU socket is protected by a plastic protective cover ...

Страница 28: ...the Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier and the Intel Xeon Non Fabric Non F processor 1 Heatsink with Thermal Grease 2 Processor Carrier 3 Non F Processor Processor Heatsink Module Bottom View ...

Страница 29: ...es below 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3 Examine all corners to ensure that the processor is firmly attached to the carrier A A B B Pin 1 Align CPU Pin 1 CPU Upside Down with CPU LGA Lands up Processor Carrier Upside Down Align Point...

Страница 30: ...d the processor carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of the assembly will lock outside of holes 1 and 2 while the remaining clips will snap into their corresponding holes 3 Examine all corners to ensure that the plastic clips on the processor ca...

Страница 31: ... protective cover installed on the CPU socket Remove it from the socket to install the Processor Heatsink Module PHM Gently pull up one corner of the plastic protective cover to remove it CPU Socket with Plastic Protective Cover Socket Pins Remove the plastic protective cover from the CPU socket Do not touch or bend the socket pins ...

Страница 32: ... With a T30 Torx bit screwdriver gradually tighten screws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not use a force greater than 12 lbf in when tightening the screws 4 Examine all corners to ensure that the PHM is firmly attached to the socket 1 2 3 4 Small Guide Post Large Guide Post Oval D T30 Tor...

Страница 33: ...f the CPU socket CPU Socket Removing the Processor Heatsink Module Before removing the processor heatsink module PHM from the motherboard unplug the AC power cord from all power supplies after shutting down the system Then follow the steps below 1 Use a T30 Torx bit screwdriver to loosen the four screws in a backwards sequence of 4 3 2 and 1 2 Gently lift the PHM upwards to remove it from the sock...

Страница 34: ... not in use Check the Supermicro website for recommended memory modules Introduction to Intel Optane DC Persistent Memory Intel 82xx 62xx 52xx 42xx supports new DCPMM Optane DC Persistent Memory Modules technology DCPMM offers data persistence with higher capacity at lower latencies than the existing memory modules and provides hyper speed storage capability for high performance computing platform...

Страница 35: ... Density One DIMM per Channel One DIMM per Channel Two DIMMs per Channel 4 Gb 8 Gb 16 Gb 1 2 Volts 1 2 Volts 1 2 Volts RDIMM SRx4 4 GB 8 GB 16 GB 2933 2933 2933 SRx8 8 GB 16 GB 32 GB DRx8 8 GB 16 GB 32 GB DRx4 16 GB 32 GB 64 GB RDIMM 3Ds QRX4 N A 2H 64GB 2H 128GB 8RX4 N A 4H 128GB 4H 256GB LRDIMM QRx4 32 GB 64 GB 128 GB LRDIMM 3Ds QRx4 N A 2H 64GB 2H 64GB 8Rx4 N A 4H 128 GB 4H 256 GB Memory Instal...

Страница 36: ...ration Key Parameters for DIMM Configurations Parameters Possible Values Number of Channels 1 2 3 4 5 or 6 Number of DIMMs per Channel 1DPC 1 DIMM Per Channel or 2DPC 2 DIMMs Per Channel DIMM Type RDIMM w ECC 3DS RDIMM LRDIMM 3DS LRDIMM DIMM Construction non 3DS RDIMM Raw Cards A B 2Rx4 C 1Rx4 D 1Rx8 E 2Rx8 3DS RDIMM Raw Cards A B 4Rx4 non 3DS LRDIMM Raw Cards D E 4Rx4 3DS LRDIMM Raw Cards A B 8Rx...

Страница 37: ... DIMMs 6 DIMMs per CPU Memory Population Sequence CPU1 6 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 CPU2 6 DIMMs CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 P2 DIMMF1 CPU3 6 DIMMs CPU3 P3 DIMMC1 P3 DIMMB1 P3 DIMMA1 P3 DIMMD1 P3 DIMME1 P3 DIMMF1 CPU4 6 DIMMs CPU4 P4 DIMMC1 P4 DIMMB1 P4 DIMMA1 P4 DIMMD1 P4 DIMME1 P4 DIMMF1 Note The drawing above shows DIMM modu...

Страница 38: ... DRAM1 DCPMM DRAM1 MM DRAM1 DCPMM DRAM1 DCPMM DRAM1 DCPMM DCPMM DRAM1 DCPMM DRAM1 DCPMM DRAM1 AD MM DRAM3 DCPMM DRAM3 DCPMM DRAM3 DCPMM DCPMM DRAM3 DCPMM DRAM3 DCPMM DRAM3 CPU3 P3 DIMMF1 P3 DIMMF2 P3 DIMME1 P3 DIMME2 P3 DIM MD1 P3 DIM MD2 P3 DIM MA2 P3 DIM MA1 P3 DIMMB2 P3 DIMMB1 P3 DIMMC2 P3 DIMMC1 AD DRAM1 DCPMM DRAM1 DCPMM DRAM1 DCPMM DCPMM DRAM1 DCPMM DRAM1 DCPMM DRAM1 MM DRAM1 DCPMM DRAM1 DCP...

Страница 39: ... P1 DIMME1 P1 DIMME2 P1 DIMMD1 P1 DIMMD2 P1 DIMMA2 P1 DIMMA1 P1 DIMMB2 P1 DIMMB1 P1 DIMMC2 P1 DIMMC1 AD DRAM1 DRAM1 DCPMM DRAM1 DCPMM DCPMM DRAM1 DCPMM DRAM1 DRAM1 MM DRAM1 DRAM1 DCPMM DRAM1 DCPMM DCPMM DRAM1 DCPMM DRAM1 DRAM1 AD MM DRAM3 DRAM3 DCPMM DRAM3 DCPMM DCPMM DRAM3 DCPMM DRAM3 DRAM3 AD DCPMM DRAM1 DRAM1 DRAM1 DRAM1 DRAM1 DRAM1 DRAM1 DRAM1 DCPMM 2 2 1 CPU2 P2 DIMMF1 P2 DIMMF2 P2 DIMME1 P2 ...

Страница 40: ...M DCPMM DRAM3 DRAM3 DRAM3 DRAM3 DCPMM CPU4 P4 DIMMF1 P4 DIMMF2 P4 DIMME1 P4 DIMME2 P4 DIMMD1 P4 DIMMD2 P4 DIMMA2 P4 DIMMA1 P4 DIMMB2 P4 DIMMB1 P4 DIMMC2 P4 DIMMC1 AD DCPMM DRAM1 DRAM1 DRAM1 DRAM1 DCPMM MM DCPMM DRAM1 DRAM1 DRAM1 DRAM1 DCPMM AD MM DCPMM DRAM3 DRAM3 DRAM3 DRAM3 DCPMM Asymmetric Population 2 1 1 1 For Channel Configuration 2 1 1 1 Modes CPU1 P1 DIMMF1 P1 DIMMF2 P1 DIMME1 P1 DIMME2 P1...

Страница 41: ... 128GB For MM general NM FM ratio is between 1 4 and 1 16 Excessive capacity for FM can be used for AD NM Near Memory FM Far Memory For each individual population rearrangements between channels are allowed as long as the resulting population is compliant with the PDG rules for the 82xx 62xx 52xx 42xx platform For each individual population please use the same DDR4 DIMM in all slots For each indiv...

Страница 42: ...DIMMD2 P3_DIMMD1 P3_DIMME2 P3_DIMME1 P2_DIMMA2 P2_DIMMA1 P2_DIMMB2 P2_DIMMB1 P2_DIMMC2 P2_DIMMC1 P2_DIMMD2 P2_DIMMD1 P2_DIMME2 P2_DIMME1 P2_DIMMF2 P2_DIMMF1 P1_DIMMF2 P1_DIMMF1 P4_DIMMC2 P4_DIMMC1 P4_DIMME1 P4_DIMMF1 P4_DIMME2 P4_DIMMF2 P4_DIMMD1 P4_DIMMD2 P3_DIMMB2 P3_DIMMA2 P3_DIMMB1 P3_DIMMA1 P3_DIMMC2 P3_DIMMC1 BIOS X X J29 J30 PCH BMC CPU2_PORT3 CPLD CPU2 SXB1C CPU3 CPU4 SXB2 SXB1B SXB1A SXB4...

Страница 43: ...ot Mechanical Electrical 1 Double width full height full length x16 CPU1 2 Double width full height full length x16 CPU1 3 Low profile half length x8 CPU2 4 Full height full length x8 CPU2 5 Full height full length x8 CPU2 6 Full height half length x8 CPU2 7 Full height half length x8 CPU2 8 Low profile internal x16 CPU3 9 Low profile internal x16 CPU3 10 Low profile internal x16 CPU4 11 Low profi...

Страница 44: ...UR66 I4G supports two full height full length x16 expansion cards Slots 1 2 RSC R2UW 4E8 supports four full height x8 expansion cards Slots 4 7 RSC R1UW E8R supports one low profile x8 expansion card Slot 3 Two RSC S2 66 each support two internal low profile x16 expansion cards Slots 8 11 Figure 3 4 Expansion and Riser Cards Rear View WIO Riser Bracket Ultra Riser Bracket ...

Страница 45: ...bracket by flipping up its riser cage release tab as pictured in Figures 3 5 3 Insert the expansion card s into the riser card slot s 4 Reinstall the riser card into the motherboard expansion slot while aligning the bracket into the chassis Flip down the riser cage release tab 5 Replace the chassis cover Figure 3 5 Riser Cage Release Tabs Ultra Riser Cage Release Tab WIO Riser Cage Release Tab ...

Страница 46: ... the cover from the chassis 2 To access the riser card remove the screw on the side of the chassis and lift out the riser card 3 Insert the expansion card s into the riser card slot s 4 Reinstall the riser card seating it in the proper slot on the motherboard Replace the screw through the side of the chassis 5 Replace the chassis cover Figure 3 6 Internal Riser Card Slots Riser Cards Brackets ...

Страница 47: ...e holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agen...

Страница 48: ...mplify their installation and removal from the chassis System power may remain on when removing carriers with drives installed These carriers also help promote proper airflow for the drive bays For this reason even empty carriers without drives installed must remain in the chassis Drive configuration All drives support SAS3 and drives HDD20 23 also support NVMe They are connected to four NVMe port...

Страница 49: ...49 Chapter 3 Maintenance and Component Installation 1 2 Figure 3 9 Removing a Drive Carrier ...

Страница 50: ...swapping hard drives do not operate the server without the carriers in the drive bays Figure 3 10 Removing a Dummy Drive from a Carrier Installing a Drive into the Carrier 1 Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes in the drive align with those in the carrier 2 Secure the hard drive into the carrier with the screws 3 Use the op...

Страница 51: ...d On SAS NVMe drive installed Blue Blinking I O activity Status LED Red Solid On Failure of drive with RSTe support Red Blinking at 1 Hz Rebuilding drive with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare for drive with RSTe support not supported in VMD mode Red On for five seconds then off Power on for drive with RSTe support Red Blinking at 4 Hz Identify drive with RST...

Страница 52: ...LD design architecture Slot is the slot number on which the NVMe drives are mounted Replacing the Drive 1 Insert the replacement drive 2 IPMI Server Health NVMe SSD 3 Select Device Group and slot and click Insert The drive Status LED indicator flashes red then turns off The Activity LED turns blue Checking the Temperature of an NVMe Drive There are two ways to check using IPMI Checking a Drive IPM...

Страница 53: ... any failed fan at your earliest convenience with the same model Failed fans can be identified through the IPMI Replacing a Mid Chassis Fan 1 Determine which fan has failed using IPMI or if necessary open the chassis while the system is running Never run the server for long without the chassis cover 2 Push the release tab and pull the failed fan from the chassis Fans can be replaced while the syst...

Страница 54: ...ly consisting of two power modules They have an auto switching capability which enables them to automatically sense and operate at a 100V 240VAC input voltage If either of the two power supply modules fail the other module will take the full load and allow the system to continue operation without interruption The Power Fail LED will illuminate and remain on until the failed unit has been replaced ...

Страница 55: ... failed power supply module 2 Press the release tab on the power supply module as illustrated 3 Use the handle to pull the module straight out of the chassis 4 Replace the failed module with an identical power supply module Push the new module into the power bay until it clicks 5 Plug the AC power cord back into the module Figure 3 16 Power Supply Release Tab ...

Страница 56: ...PSU1 PSU2 are located on J24 J25 on the motherboard Connect these connectors to your power supply to provide power to your system See the layout drawing below for the locations of PSU1 and PSU2 12V 8 pin CPU Power Connectors In addition to the main power supply units there are seven 8 pin 12V DC power connectors located on the motherboard Four of these 8 pin power connectors JPWR1 JPWR4 are used f...

Страница 57: ...connect a Trusted Platform Module TPM Port 80 which is available from a third party vendor TPM Port 80 is a security device which supports encryption and authentication in hard drives It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system See the layout drawing below for the location of JTPM1 RAID Key Header A RAID Key header is located at...

Страница 58: ...ons SATA Power Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground I SATA 3 0 and S SATA 3 0 Ports The X11QPH has eight I SATA 3 0 ports I SATA0 3 I SATA4 7 and six S SATA S SATA0 3 S SATA4 S SATA5 on the motherboard The I SATA ports are supported by the Intel C621 chipset and the S SATA ports are supported by Intel SCU S SATA4 S SATA5 can be used with Supermicro SuperDOMs which are yellow SATA ...

Страница 59: ...1 JWD1 JPME1 JL1 JBT1 JRK1 JUSB2 BMC_HB _LED1 JF1 JSTBY1 P3_DIMMF1 P3_DIMMD2 P3_DIMMD1 P3_DIMME2 P3_DIMME1 P2_DIMMA2 P2_DIMMA1 P2_DIMMB2 P2_DIMMB1 P2_DIMMC2 P2_DIMMC1 P2_DIMMD2 P2_DIMMD1 P2_DIMME2 P2_DIMME1 P2_DIMMF2 P2_DIMMF1 P1_DIMMF2 P1_DIMMF1 P4_DIMMC2 P4_DIMMC1 P4_DIMME1 P4_DIMMF1 P4_DIMME2 P4_DIMMF2 P4_DIMMD1 P4_DIMMD2 P3_DIMMB2 P3_DIMMA2 P3_DIMMB1 P3_DIMMA1 P3_DIMMC2 P3_DIMMC1 BIOS X X J29 ...

Страница 60: ...the UID switch the UID LED indicator will be turned on Press the UID switch again to turn off the LED The UID Indicator provides easy identification of a system unit that may be in need of service Note UID can also be triggered via IPMI on the motherboard For more information on IPMI please refer to the IPMI User s Guide posted on our website at http www supermicro com UID Switch Pin Definitions P...

Страница 61: ...B access Cables are not included Back Panel USB 2 3 3 0 Pin Definitions Pin Definition Pin Definition A1 VBUS B1 Power A2 D B2 USB_N A3 D B3 USB_P A4 GND B4 GND A5 Stda_SSRX B5 USB3_RN A6 Stda_SSRX B6 USB3_RP A7 GND B7 GND A8 Stda_SSTX B8 USB3_TN A9 Stda_SSTX B9 USB3_TP Front Panel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 VUBS 2 VUBS 3 USB_N 4 USB_N 5 USB_P 6 USB_P 7 Ground 8 Gr...

Страница 62: ...CPU3 CPU4 SXB2 SXB1B SXB1A SXB4A SXB4B USB0 1 CPU1_PORT2 SXB3C CPU1_PORT1 SXB3B VGA UID COM1 I SATA0 3 S SATA0 3 I SATA4 7 USB 4 3 0 USB 2 3 3 0 IPMI_LAN CPU2_PORT2 CPU2_PORT1 CPU1 BACKPLANE POWER GPU POWER P1_DIMMB1 P1_DIMMC1 P1_DIMMB2 P1_DIMMC2 P1_DIMMA1 P1_DIMMA2 WIO 2x16 PCI E 3 0 PCI E 3 0 RSC 56 Lanes PCI E 3 0 RSC 48 Lanes Ultra IO X40 PSU2 PSU1 J12VSB SXB5B SXB5A CPU2_PORT3 CPU3_PORT2 CPU3...

Страница 63: ... is located on pins 5 and 6 of JF1 Refer to the table below for pin definitions Power Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail Informational LED UID OH PWR Fail Fan Fail LED Pin Definitions Pin 7 Pin 8 of JF1 Status Description Solid red An overheat condition has occurred This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Bl...

Страница 64: ...DD LED The HDD LED connection is located on pins 13 and 14 of JF1 Attach a cable to pin 14 to show hard drive activity status Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pins Definition 13 3 3V Stdby 14 HDD Active Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table below for pin definitions Power LED Pin Definitions JF1 Pins Defini...

Страница 65: ... Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the system and unplug the power cord s 2 Remove the cover of the chassis to access the motherboard 3 Remove the onboard battery from the mother...

Страница 66: ...for jumper settings Manufacturer Mode Jumper Settings Jumper Setting Definition Pins 1 2 Normal Pins 2 3 ME Recovery Watch Dog JWD1 controls the Watch Dog function Watch Dog is a monitor that can reboot the system when a software application hangs Jumping pins 1 2 will cause Watch Dog to reset the system if an application hangs Jumping pins 2 3 will generate a non maskable interrupt signal for the...

Страница 67: ...n BMC is functioning normally See the table below for the LED status BMC Hearbeat LED Indicator LED Color Definition Green Blinking BMC Normal Onboard Power LED The Onboard Power LED is located at LED2 on the motherboard When this LED is on the system is on Be sure to turn off the system and unplug the power cord before removing or installing components Refer to the table below for more informatio...

Страница 68: ...ite at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive or the IPMI KVM console 2 Retrieve the proper RST RSTe driver Go to the Supermicro web page for your motherboard and click on Download the Latest Drivers and Utilities select the proper dri...

Страница 69: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the SATA sSATA AHCI driver indicated then choose the storage drive on which you want to install it 5 Once all devices are specified continue with the installation 6 After the Windows OS installation has c...

Страница 70: ... preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or disk and the screenshot shown below should appear Figure 5 1 Driver Tool Installation Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Cli...

Страница 71: ... monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Figure 5 2 SuperDoctor 5 Interface Display Screen Health Information 5 4 IPMI The X11QPH supports the Intel...

Страница 72: ...e used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Ofte...

Страница 73: ...em date and time Highlight System Date or System Time using the arrow keys on the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 The date s default value is 01 01 2014 after RTC reset Supermicro X11QPH BIOS Ver...

Страница 74: ...ry Speed This item displays the default speed of the memory modules installed in the system 6 3 Advanced Settings Menu Use the arrow keys to select the Advanced submenu and press Enter to access the submenu items Warning Take Caution when changing the Advanced settings An incorrect value an incorrect DRAM frequency or an incorrect BIOS timing setting may cause the system to malfunction When this o...

Страница 75: ... Enabled Interrupt 19 Trap Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Immediate the ROM BIOS of the host adaptors will capture Interrupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Postponed the ROM BIOS of the host adaptors will not captu...

Страница 76: ...oss Select Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last power state before a power loss The options are Power On Stay Off and Last State CPU Configuration Warning Setting the wrong values in the features below may cause the system to malfunction Processor Configuration The following CPU information will be displayed Proce...

Страница 77: ...options are Unlock Enable and Unlock Disable Hardware Prefetcher Available when supported by the CPU If this feature is set to Enable the hardware prefetcher will prefetch streams of data and instructions from the main memory to the Level 2 L2 cache to improve CPU performance The options are Disable and Enable Adjacent Cache Prefetch Available when supported by the CPU Select Enable for the CPU to...

Страница 78: ...n and heat dissipation Please refer to Intel s website for detailed information The options are Disable and Enable EIST PSD Function Available when SpeedStep is set to Enable Use this feature to configure the processor s P State coordination settings During a P State the voltage and frequency of the processor will be reduced when it is in operation This makes the processor more energy efficient re...

Страница 79: ...urned off The options are Auto Enable and Disable Enhanced Halt State C1E Select Enable to enable Enhanced Halt State support which will significantly reduce the CPU s power consumption by minimizing CPU s clock cycles and reduce voltage during a Halt State The options are Disable and Enable Package C State Control Package C State Use this feature to set the limit on the C State package register T...

Страница 80: ... are in conflict The options are Topology Precedence and Feature Precedence Link L0p Enable Select Enable to enable Link L0p The options are Disable Enable and Auto Link L1 Enable Select Enable to enable Link L1 Level 1 link The options are Disable Enable and Auto IO Directory Cache Select Enable for the IODC I O Directory Cache to generate snoops instead of generating memory lockups for remote II...

Страница 81: ...laxation If this feature is set to Enable SPD Serial Presence Detect will override tCCD_L Column to Column Delay Long or Command to Command Delay Long on the column side If this feature is set to Disable tCCD_L will be enforced based on the memory frequency The options are Enable Disable and Auto Enable ADR Select Enable for ADR Automatic Diagnostic Repository support to enhance memory performance...

Страница 82: ...ot be available when memory mirror mode is enabled Correctable Error Threshold Use this item to enter the threshold value for correctable memory errors The default setting is 10 SDDC Plus One Select Enable for SDDC Single Device Data Correction Plus One support which will increase the reliability and serviceability of your system memory The options are Enable and Disable ADDDC Adaptive Double Devi...

Страница 83: ...feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU2 IIO PCIe Br3 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto MCP0 IIO PCIe Br4 This feature configures the PCI E Bifuraction setting for a PCI E por...

Страница 84: ...r4 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto MCP1 IIO PCIe Br5 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto PCI E Completion Timeout Disable Select Enable to enable PCI E Completion Timeout support The options are Enable and Disable PCI E Comp...

Страница 85: ...Br5 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto PCI E Completion Timeout Disable Select Enable to enable PCI E Completion Timeout support The options are Enable and Disable PCI E Completion Timeout Value This feature allows the user to set the PCI E Completion Timeout value The default setting is 260ms to 900ms Sck3 Sock...

Страница 86: ... prioritize the TPL requests that will allow the hints to be sent to help facilitate and optimize the processing of certain transactions in the system memory The options are Enable and Disable Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain transactions to violate the strict ordering rules of PCI and to be completed prior to other transactions that have a...

Страница 87: ...errupts The options are Enable and Disable Coherency Support Non Isoch Select Enable for the Non Iscoh VT d engine to pass through DMA Direct Memory Access to enhance system performance The options are Enable and Disable Intel VMD Technology Intel VMD for Onboard NVMe Intel VMD for Volume Management D Select Enable to enable Intel Volume Management Device Technology in the stack The default settin...

Страница 88: ...imeout Global Select Yes to disable the PCI E Completion Time out settings The options are Yes No and Per Port South Bridge The following South Bridge information will display USB Module Version USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select Auto to disable legacy support if there are no legacy USB devices present Select Disable to have all USB devices a...

Страница 89: ... the SATA devices that are supported by the Intel PCH chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enable and Disable Configure SATA as Available when the item above SATA Controller is set to enabled Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select R...

Страница 90: ... to 1 set this item to allow the SATA device installed on the SATA port specified by the user to start a COMRESET initialization The options are Enable and Disable SATA Device Type Use this item to specify if the device installed on the SATA port selected by the user should be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive PCH sSATA Conf...

Страница 91: ...cy sSATA Port 0 sSATA Port 5 Hot Plug Select Enable to support Hot plugging for the device installed on an sSATA port selected by the user which will allow the user to replace the device installed in the slot without shutting down the system The options are Disable and Enabled Spin Up Device On an edge detect from 0 to 1 set this item to allow the sSATA device installed on the sSATA port specified...

Страница 92: ...utomatically set the maximum size for a read request for a PCI E device to enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes MMCFG Base This feature determines the lowest MMCFG Memory Mapped Configuration base assigned to PCI devices The options are 1G 1 5G 1 75G 2G 2 25G and 3G VGA Priority This feature selects the graphics device t...

Страница 93: ...P boot support If this feature is disabled it will not create the Ipv6 HTTP boot option The options are Enabled and Disabled PXE Boot Wait Time Use this feature to select the wait time to press the ESC key to abort the PXE boot The default is 0 Media Detect Time Use this feature to select the wait time in seconds for the BIOS ROM to detect the LAN media Internet connection or LAN port The default ...

Страница 94: ...s item is hidden when Serial Port 1 is set to Disabled Change Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 2 Select Auto for the BIOS to automatically assign the base I O and IRQ address to a serial port specified The options for Serial Port 2 are Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E...

Страница 95: ...and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mar...

Страница 96: ... Redirection for COM2 SOL Select Enabled to use the SOL port for Console Redirection The options are Enabled and Disabled If the item above set to Enabled the following items will become available for user s configuration Console Redirection Settings for SOL COM2 Use this feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the u...

Страница 97: ...Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start data sending when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ...

Страница 98: ...ion The options are Disabled and Enabled If the item above set to Enabled the following items will become available for user s configuration EMS Console Redirection Settings Out of Band Management Port The feature selects a serial port in a client server to be used by the Windows Emergency Management Services EMS to communicate with a remote host server The options are COM1 Console Redirection and...

Страница 99: ...ndows Hardware Error Architecture WHEA platform and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring The options are Enabled and Disabled High Precision Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a muc...

Страница 100: ... included in the list of public keys During system boot the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform firmware used in a host system via a TPM device The options are Enabled and Disabled Storage Hierarchy Select Enabled for TPM Storage Hierarchy support that is intended to be used for non privacy se...

Страница 101: ...to enhance system security and data integrity The options are Disabled and Enabled Note 1 If the option for this item TXT Support is set to Enabled be sure to disable EV DFX Device Function On Hide support for the system to work properly EV DFX is under IIO Configuration in the Chipset North Bridge submenu Note 2 For more information on TPM please refer to the TPM manual at http www supermicro com...

Страница 102: ...tions SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are No Yes Next Reset and Yes Next Reset ...

Страница 103: ... multiple event counter should wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect Customer Options Log OEM Codes Select Enabled to log the EFI Status codes as OEM codes if these codes have not been converted to Legacy The options are Enabled and Disabled Convert OEM Codes Select Enabled to con...

Страница 104: ...e following information will display IPMI Firmware Revision This feature indicates the IPMI firmware revision used in your system Status of BMC This feature indicates the status of the BMC Baseboard Management Controller installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled ...

Страница 105: ...and progress codes The options are Disabled Both Error code and Progress code Note After making changes on a setting be sure to reboot the system for the changes to take effect BMC Network Configuration The following items will be displayed IPMI LAN Selection This feature displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link...

Страница 106: ...AN Selection Use this feature to configure the IPMI LAN mode setting The options are Dedicated Shared and Failover VLAN Support Select Enabled for IPMI VLAN support The options are Disabled and Enabled Configuration Address Source Use this feature to select the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system...

Страница 107: ...gth of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a password at bootup or upon ...

Страница 108: ...ement Provision Factory Default Keys Select Enabled to install all manufacturer default keys to configure the following system security settings The options are Enabled and Disabled Install Factor Default Keys Select Yes to install all manufacturer defaults to configure the following system security settings The options are Yes and No Enroll EFI Image Select this item and press Enter to select an ...

Страница 109: ...t New and Append Secure Boot Variable Size Key Key Sources The options are Save to File Set New and Erase Forbidden Signatures This feature allows the user to enter and configure a set of values to be used as Forbidden Signatures for the system These values also indicate the size the keys numbers and the key source of the Forbidden Signatures The options are Save to File Set New and Erase Authoriz...

Страница 110: ...d Dual Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press Enter on each entry from top to bottom to select devices When the item above Boot Mode Select is set to Dual default the following items will be displayed for configuration Boot Option 1 Boot Option 15 When the item above Boot Mode Select is set to Legacy the following i...

Страница 111: ...ress Enter to create the new boot option in the boot priority list Delete Boot Option Use this feature to select a boot device to delete from the boot priority list Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list Add New Driver Option Use this feature to select a new driver to add to the boot priority list Add Driver Option Use this feature to specify t...

Страница 112: ...e Option Select the target boot driver to delete from the boot priority list Hard Disk Drive BBS Priorities Boot Option 1 5 Network Drive BBS Priorities Boot Option 1 USB Key Drive BBS Priorities Boot Option 1 UEFI Hard Disk Drive BBS Priorities Boot Option 1 UEFI USB Key Drive BBS Priorities Boot Option 1 UEFI Application Boot Priorities Boot Option 1 ...

Страница 113: ...lect Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters to take effect Select Save Changes and Exit from the Exit menu and press Enter Save Changes When you have completed the system configura...

Страница 114: ...ave As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved previously Boot Override This feature allows th...

Страница 115: ...oot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error BIOS Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been ...

Страница 116: ...rmicro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic card can be attached to the computer to read I O port 0080h Supermicro p n AOC LPC80 20 For information on AMI updates please refer to http www ami com products ...

Страница 117: ... configuring components in the Supermicro chassis These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Warning Definition 警告の定義 この警告サインは危険を意味します 人身事故につながる可能性がありますので いずれの機器でも動作させる前に 電気回路に含まれる危険性に注意して 標準的な事故防止策に精通して下さい 此警告符号代表危险 您正处于可能受到严重伤害的工作环境中 在您使用设备开始工作之前 必须充分意识到触电 的危险 并熟练掌握防止事故发生的标准工作程序 请根据每项警告结尾的声明号码找到此设 备的安全性警告说明的翻译文本 此警告符號代表危險 您正處於...

Страница 118: ...rará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés a...

Страница 119: ...okken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい 警告 将此系统连接电源前 请先阅...

Страница 120: ...에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい 警告 此产品的短路 过载电流 保护由建筑物的供电系统提供 确保短路保护设备的额定电流不大于 250V 20A 警告 此產品的短路 過載電流 保護由建築物的供電系統提供 確保短路保護設備的額定電流不大於 250V 20A Warning This product relies on the building s installation for short circuit overcurrent pro...

Страница 121: ... surtension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde ...

Страница 122: ...en oder zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d accé...

Страница 123: ...l replace or service this equipment 機器の設置 トレーニングを受け認定された人だけがこの装置の設置 交換 またはサービスを許可されていま す 警告 只有经过培训且具有资格的人员才能进行此设备的安装 更换和维修 警告 只有經過受訓且具資格人員才可安裝 更換與維修此設備 Warnung Das Installieren Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo امداد وحدة من انكهرباء سهك...

Страница 124: ...僅限安裝於進出管制區域 進出管制區域係指僅能以特殊工具 鎖頭及鑰匙或其他安全 方式才能進入的區域 Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of securit...

Страница 125: ...d accès réservés L accès à une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen ver...

Страница 126: ... manera incorrecta Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante 電池の取り扱い 電池交換が正しく行われなかった場合 破裂の危険性があります 交換する電池はメーカーが推 奨する型 または同等のものを使用下さい 使用済電池は製造元の指示に従って処分して下さい 警告 电池更换不当会有爆炸危险 请只使用同类电池或制造商推荐的功能相当的电池更换原有电 池 请按制造商的说明处理废旧电池 警告 電池更換不當會有爆炸危險 請使用製造商建議之相同或功能相當的電池更換原有電池 請按 照製造商的說明...

Страница 127: ...wer Supplies Warning This unit might have more than one power supply connection All connec tions must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さなければなりません 警告 此部件连接的电源可能不止一个 必须将所有电源断开才能停止给该部件供电 警告 此裝置連接的電源可能不只一個 必須切斷所有電源才能停止對該裝置的供電 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugeführ...

Страница 128: ...na conexión para fuentes de alimentación Para cortar por completo el suministro de energía deben desconectarse todas las conexiones Attention Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées אחד מספק יותר קיים אם אזהרה לרוקן מנת על החיבורים כל את להסיר יש ספק ש...

Страница 129: ...sicht bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use ...

Страница 130: ...kplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Attention L équipement doit être installé conformément aux normes électriques nationales et locales 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warning Installation of the equipment must comply w...

Страница 131: ...理應根據所有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according to all national laws and regulations Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales הארצי החשמל חוקי תיאום אזהרה והארציים המקומיים החשמל לחוקי תואמ...

Страница 132: ...arts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing ファン ホッ トスワップの警告 警告 回転部品に注意 運転中は回転部 羽根 に触れないでく ださい シャーシから冷却ファン装 置を取り外した際 ファンがまだ回転している可能性があります ファンの開口部に 指 ドライバ ー およびその他のものを近づけないで下さい 警告 警告 危险的可移动性零件 请务必与转动的风扇叶片保持距离 当您从机架移除风扇装置 风扇可能仍在转动...

Страница 133: ...is Prenez garde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur 경고 움직이는 위험한 부품 회전하는 송풍 날개에 접근하지 마세요 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다 팬 조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버 다른 물체들이 가까이 하지 않도록 배치해 주십시오 Waarschuwing Gevaarlijk bewegende onderdelen Houd voldoende afstand tot de bewegende ventilatorbladen Het is mogelijk dat de ventilator nog draait tijde...

Страница 134: ...グと共に使用下さい 他のケー ブルやアダプタを使用すると故障や火災の原因になるこ とがあります 電気用品安全法は ULまたはCSA認定のケーブル UL CSAマークがコードに表記 を Supermicro が指定する製品以外に使用するこ とを禁止しています 警告 安装此产品时 请使用本身提供的或指定的或采购的连接线 电源线和电源适配器 包含遵照当 地法规和安全要求的合规的电源线尺寸和插头 使用其它线材或适配器可能会引起故障或火灾 除了Supermicro所指定的产品 电气用品和材料安全法律规定禁止 使用未经UL或CSA认证的线材 线材上会显示UL CSA符号 警告 安裝此產品時 請使用本身提供的或指定的或採購的連接線 電源線和電源適配器 包含遵照當 地法規和安全要求的合規的電源線尺寸和插頭 使用其它線材或適配器可能會引起故障或火災 除了Supermicro所指定的產品 電氣用品和材料安全法...

Страница 135: ...י החשמל במכשירי השימוש לחוקי UL ב או CSA קוד עליהם מופיע כאשר של UL CSA ע י הותאם אשר במוצר רק אלא אחר חשמלי מוצר כל עבור Supermicro בלבד ذلك يف مبا املحلية السالمة ومتطلبات بقوانني ام ز االلت مع املرتدد التيار ومحوالت الكهربائية الكابالت اء رش ب قم أو املحددة أو املتوفرة التوصيالت باستخدام قم املنتج تركيب عند املعتمدة الكابالت استخدام واملعدات الكهربائية لألجهزة السالمة قانون يحظر حريق أو عطل يف ...

Страница 136: ...sluiten van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of brand veroorzaken Wetgeving voor Elektrische apparatuur en Materiaalveiligheid ver...

Страница 137: ...s up to 11 PCI Express 3 0 expansion cards by means of four riser cards seven external four internal two can be double width GPUs Motherboard X11QPH Chassis CSE 218UTS R1K62P 2U Rackmount WxHxD 17 2 x 3 5 x 30 7 in 437 x 89 x 780 mm System Cooling Four 8 cm PWM fans Power Supply Model PWS 1K62A 1R AC Input Voltages 100 127 200 240 VAC Rated Input Current 13 9A 100 127VAC 10 8A 200 240VAC Rated Inp...

Страница 138: ... 61000 4 6 EN 61000 4 8 EN 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive Product Safety 2014 35 EU LVD Directive UL CSA 62368 1 USA and Canada IEC EN 62368 1 Perchlorate Warning California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coi...

Страница 139: ...ery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On Self Test routines Note 1 Follow the BIOS recovery instructions below for BIOS recovery when the main BIOS...

Страница 140: ...file into the Root directory of a USB device or a writable CD DVD Note If you cannot locate the Super ROM file in your drive disk visit our website at www supermicro com to download the BIOS package Extract the BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use 2 Insert the USB device that contains the new BIOS image Super ROM into your USB drive and reset ...

Страница 141: ...hown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt the BIOS flashing process until it has completed 5 After the BIOS recovery process is complete press any key to reboot the system 6 Using a different system extract the BIOS package into a USB flash dr...

Страница 142: ...to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do not interrupt this process until the BIOS flashing is complete 7 Press Del continuously during system boot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submen...

Страница 143: ... unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load the default settings 12 After loading the default settings press F4 to save the settings and exit the BIOS Setup utility ...

Страница 144: ...類如下 Additional traditional Chinese versions of warning statements are included in this appendix WARNING 警告 此注意標誌提醒未能依照正確指示使用機器 可能導致生命危險 或造成嚴重傷害 CAUTION 注意 此注意標誌提醒未能依照正確指示使用機器 可能導致受傷或財產損失 此標誌提示絕對不可做的動作 此標誌提示一般性務必要採取的行為 本機器必須用接地線與地面確實連接 否則受到電擊或閃電時 將對您造成危險 如 果電源插座沒有接地端子 或是有無法接地情況 請務必洽詢專業技術人員 妥善安 裝這些設施 WARNINGS警告 1 電源必須在 100V 至 240V 正負 10 之間 2 使用額定合格開關來提供電源迴路 3 機器安裝愈接近電源插座愈好 4 移動機器必須由維護工程師來處理 ...

Страница 145: ...產生怪味或不正常聲響 必需立即關閉機器電源開關 然後 從插座取下 插頭 2 絕對不可以沾濕的手插拔插頭 否則可能受到電擊 3 插頭必須確實插妥在插座上 如果未能妥善插好 可能會引起火災 4 僅可使用機器所附電源插頭 警告使用者 這是甲類的資訊產品 在居住的環境中使用時 可能會造成射頻干擾 在這種情況下 使用者會被要求採取某些適當的對策 1 移動機器前 必須記住拔下插頭 否則插頭可能受損而引起火災 或受到電擊 2 為安全起見 夜晚無人使用伺服器時 必須確實將它的電源關閉 3 連續假日長期無人使用伺服器時 必須確實將它的電源關閉 4 插座周圍必須淨空 以便隨時可以很輕易的拔下插頭 拔取電源線時 確實抓住插頭部位 否則導致插頭破裂可能引起火 災或受到電擊 不可企圖拆解或擅自修改機器 否則可能引起火災或受到電擊 不可將機器安裝在下列場所 1 濕氣高及多灰塵的地方 2 地板不穩的地方 如果機器傾倒 ...

Страница 146: ...142 SuperServer SYS 2049U TR4 User s Manual ...

Страница 147: ...id Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel RSTe Driver for Windows To enable Intel VROC a hardware key must be inserted on the motherboard and the ap propriate processor s Virtual Management Devices must be enabled in the BIOS setup It is ...

Страница 148: ...r JRK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs AOC VROCPREMOD 951606 Intel SSD only RAID 0 1 5 10 Supports Intel SSDs only AOC VROCINTMOD 956822 Additional Information Additional information is available on the product page for the Superm...

Страница 149: ...et Configuration North Bridge IIO Configuration Intel VMD Technology Intel VMD for Volume Managent Device on CPU 4 5 Enable the VMD according to the following rules For U 2 NVMe enable all the sub items under each PStack based on the your model server VMD BIOS Setting CPU4 VMD Config for PStack0 For M 2 NVMe or NVMe AIC enable the VMD according to which AOC card slot it used An example U 2 configu...

Страница 150: ... RAID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure F 4 12 Select specific disks for RAID with an X RAID0 Select at least two 2 24 disks RAID1 Select only two disks RAID5 Select at least three 3 24 disks RAID10 Select only four disks 13 Select Strip Size Defa...

Страница 151: ...rmation at link 1 below Hot unplug 1 Prevent devices from being re detected during rescan esxcli storage core claiming autoclaim enabled false 2 Unmount the VMFS volumes on the device Check 2 for details 3 Detach the device Check 3 for details 4 Physically remove the device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some c...

Отзывы: