Supermicro SUPERSERVER 9029GP-TNVRT Скачать руководство пользователя страница 116

116

SuperServer 9029GP-TNVRT User's Manual

Warnung 
Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. 
Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung 
nicht mehr als: 250 V, 20 A beträgt.

¡Advertencia! 
Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del 

edificio. Asegúrese de que el dispositivo de protección no sea superior a: 250 V, 20 A.

Attention 
Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de 

l'installation électrique du local. Vérifiez que le courant nominal du dispositif de protection 

n'est pas supérieur à :250 V, 20 A.

경고!

이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 
보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. 

Waarschuwing 

Dit  product  is  afhankelijk  van  de  kortsluitbeveiliging  (overspanning)  van  uw  electrische 

installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V, 20A.

יכ אדוול שי .ילמשח רצק תעינמל םינבמב תנקתומה הנגה לע ךמתסמ הז רצומ

250VDC, 20A-מ רתוי אל אוה ילמשחה רצקה ינפמ ןגמה רישכמה

في اهتيبثت مت يتلا ةيرصقلارئاودلا هم تيماحلا ثادعم لىع دمتعي جتنلما اذه

ىنبلما

20A, 250V : نم ثركأ سيل ئياقولا زاهجلا مييقت نأ نم دكأت

Содержание SUPERSERVER 9029GP-TNVRT

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 9029GP TNVRT...

Страница 2: ...an industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...s and utilities https www supermicro com wftp Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support sup...

Страница 4: ...ack Installation 2 1 Preparing for Setup 19 Choosing a Setup Location 19 Rack Precautions 19 Server Precautions 20 Rack Mounting Considerations 20 Ambient Operating Temperature 20 Airflow 20 Mechanica...

Страница 5: ...Installing the GPU Trays 45 Installing the NVLink Bridges 46 Switch Trays 47 Storage Drives 48 Drive Carriers 48 Hot Swap for NVMe Drives 51 Checking the Temperature of an NVMe Drive 52 Installing M 2...

Страница 6: ...Main Setup 69 6 3 Advanced Setup Configurations 71 6 4 Event Logs 99 6 5 IPMI 101 6 6 Security 104 6 7 Boot 107 6 8 Save Exit 109 Appendix A BIOS Error Codes Appendix B Standardized Warning Statement...

Страница 7: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...

Страница 8: ...age drive bridge head node BPN GPU 1018G AOM SBL SAS3 1 1 NVLink bridges AOM HGX2 NVL P 6 pairs Riser cards switches Riser card PCIe expansion cards RSC G 66 HGX2 RSC G A66 8 1 Fans FAN 0196L4 FAN 019...

Страница 9: ...cfm Socket Type Socket P0 LGA3647 Memory Supports up to 3 TB of DDR4 3DS ECC RDIMM LRDIMM in 24 DIMM slots up to 2666MHz Chipset Intel C621 Expansion Slots Sixteen NVIDIA V100 GPUs plus two PCIe x16...

Страница 10: ...below for details 7 Unit ID LED Solid blue indicates UID has been activated locally Blinking blue indicates UID has been activated using IPMI to locate the server in a rack environment 8 UID Reset Bu...

Страница 11: ...1 Control Panel See previous page for details 2 Drive Bays Sixteen NVMe hot swap 2 5 storage drive carriers each has status indicators see Section 3 4 3 Fans Eight 9 cm fans and six 8 cm fans Figure...

Страница 12: ...old up to eight Network Interface Cards 3 BMC Sticker Sticker shows the BMC default password see Section 5 4 4 Expansion Slots Two slots for external cards 5 Storage Drives Six SATA hot swap 2 5 drive...

Страница 13: ...GA 4 USB 1 USB 3 0 2 LAN1 5 USB 2 USB 3 0 3 LAN2 shared 6 IPMI LAN 3 1 5 4 2 6 Figure 1 5 Chassis Rear View Showing NVLink Bridge Assemblies Six NVLink Bridge Assemblies NVLink bridge assemblies conne...

Страница 14: ...14 SuperServer 9029GP TNVRT User s Manual 2 5 3 4 6 1 Figure 1 5 Chassis Trays Rear Chassis Trays Item Feature 1 2 GPU Trays 3 4 Switch Trays 5 Head Node Tray 6 Power Tray Chassis Trays...

Страница 15: ...cations shown See the following page for descriptions For detailed descriptions pinout information and jumper settings refer to Chapter 4 JPL1 JWD1 COM1 FAN2 debug JVRM CPU2 CPU1 BT1 JBM_ E1 E2 E3 JBM...

Страница 16: ...use only JBMC_DEBUG1 2 FAN1 FAN3 System CPU fan headers FAN 1 FAN 3 HDD0 HDD2 Drive connectors connectors for HDD3 5 are on a bridge card HDD3 5 Header for backplane supporting HDD 3 4 5 IPMI_LAN Ded...

Страница 17: ...ng though the CPUs Note The two switch boards must always be present for the GPUs and NICs to be detected Midplane Provides connections between the system trays and for the NVMe drives NVLink bridges...

Страница 18: ...x16 x16 x16 x16 x16 x16 x16 x16 x16 x16 x16 x16 x16 x16 x4 x8 x8 x8 x8 S SW WI IT TC CH H 1 1 CPU2 PLX PLX PLX PLX PLX PLX 2x NVMe HGX 2 2x NVMe 2x NVMe 2x NVMe x16 NIC NIC NIC NIC NIC NIC NIC NIC x16...

Страница 19: ...oor completely 25 inches and approximately 30 inches of clearance in the back of the rack to allow sufficient space for airflow and access when servicing This product should be installed only in a Res...

Страница 20: ...tain proper cooling Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be gre...

Страница 21: ...t the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit...

Страница 22: ...ations of the screws for the rails 3 In each rail set the two sections are screwed together to keep them immobile during shipping Release these screws just enough to allow the rail sections to slide a...

Страница 23: ...umbscrew through the bottom hole of each handle Note These handles need only be installed when mounting the system into a short rack When mounting into a deep rack they are unnecessary and regular scr...

Страница 24: ...SuperServer 9029GP TNVRT User s Manual 24 Figure 2 3 Installing the Server onto the Rails...

Страница 25: ...power from the system before installing or replacing components 3 1 Removing Power Use the following procedure to verify that power has been removed from the system This step is required when removin...

Страница 26: ...ual 26 Figure 3 1 Chassis Rear with Trays Out 3 2 Accessing the System The system is comprised of six trays Each tray can be removed from the chassis using release levers Before removing the trays pow...

Страница 27: ...27 Chapter 3 Component Installation and Maintenance Figure 3 2 Tray Levers Released...

Страница 28: ...lies as described in this chapter Section 3 4 2 On the release levers remove the locking screws one each side 3 Press the release lever latches outward and pull the levers 4 Use the levers to pull out...

Страница 29: ...ase levers remove the locking screws one each side 2 Use the tab on the edge of the lever to rotate the lever out 3 Use the levers to pull out the tray Note When re inserting the tray be sure the leve...

Страница 30: ...e Head Node motherboard Tray On the release lever on the right side press the outward and pull out the tray Note When re inserting the tray be sure the levers are in the fully open positions Figure 3...

Страница 31: ...o locking screws 2 Press the release lever latches outward and pull the levers Figure 3 7 Releasing the Power Supply Tray Latch Release lever Figure 3 6 Locking Screws for the Power Supply Tray Lockin...

Страница 32: ...One section of the chassis top can be removed This is useful when removing the midplane 1 On the each side of the chassis remove the locking screws 2 Pull up on the two release levers and lift off the...

Страница 33: ...lug the AC power cord from all power supplies after shutting down the system Check that the plastic protective cover is on the CPU socket and none of the socket pins are bent If they are contact your...

Страница 34: ...Manual 34 Overview of the Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier assembly Heatsink with Thermal Grease Processor Carrier Processor Process...

Страница 35: ...w 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3...

Страница 36: ...arrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of the as...

Страница 37: ...tion This motherboard comes with a plastic protective cover on the CPU socket Remove it carefully to install the Processor Heatsink Module PHM CPU Socket with Plastic Protective Cover Socket Pins Remo...

Страница 38: ...s 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not use a force greater than 12 lbf in when tightening t...

Страница 39: ...emory support DDR4 Memory Support for the Intel Xeon Scalable processor Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s One Slot per Channel Two Slots per Channel DRAM Density One DIMM...

Страница 40: ...xed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in the sa...

Страница 41: ...1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 CPU2 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 10 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMM...

Страница 42: ...talled on the motherboard Install the processors starting with CPU Socket 1 CPU1 P1 DIMMA1 P1 DIMMA2 P1 DIMMD2 P1 DIMME2 P1 DIMMD1 P1 DIMME1 P1 DIMMF2 P1 DIMMF1 P1 DIMMB1 P1 DIMMC1 P1 DIMMB2 P1 DIMMC2...

Страница 43: ...wer from the system as described in Section 3 1 Follow the memory population sequence in the preceding table 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release...

Страница 44: ...nder the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a dama...

Страница 45: ...dor and shipped separately You must install the trays Installing GPU Trays 1 Note that the release levers on each side must be in the fully open position 2 Slide each tray into the chassis 3 Lift the...

Страница 46: ...e latch mechanism in the Release position hold the bridge assembly with both hands fingers under the latch mechanism and thumbs on top of the assembly 3 Align the two poles on the contact side of the...

Страница 47: ...icular squeeze to pull the latch down while pulling the assembly straight out from the GPU trays Switch Trays Installing Switch Trays 1 Note that the release levers on each side must be in the fully o...

Страница 48: ...proper airflow Each drive carrier has two LED indicators an activity indicator and a status indicator In RAID configurations the status indicator lights to indicate the status of the drive In non RAID...

Страница 49: ...allation and Maintenance Figure 3 14 Removing a Hard Drive Carrier Removing Drive Carrier 1 Press the release button on the drive carrier to extend the drive carrier handle 2 Use the handle to pull th...

Страница 50: ...g the dummy drive into the drive carrier and remove the dummy drive 2 Install a drive into the carrier with the printed circuit board side facing down so that the mounting holes in the drive align wit...

Страница 51: ...and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architecture The 9029GP TNVRT serve...

Страница 52: ...1 Power down the system as described in Section 3 1 and remove the head node motherboard tray 2 Locate the M 2 slots M 2 P1 M 2 P2 on the motherboard 3 The M 2 card will be held in place by a plastic...

Страница 53: ...ith a failed fan although it may shut down if the heat gets too great Replace any failed fan at your earliest convenience with the same model Failed fans can be identified through the IPMI Changing a...

Страница 54: ...ir shrouds concentrate airflow to maximize fan efficiency The SC1018G chassis air shroud does not require screws to set up Installing the Air Shroud Begin by removing power from the system as describe...

Страница 55: ...ower module will automatically take over The failed power module can be replaced without powering down the system Replace with the same model Replacement modules can be ordered directly from Supermicr...

Страница 56: ...s the bracket is secured by a small black plastic flip switch with an arrow on it Flip open the switch to release the bracket then pull the bracket out of the chassis 3 Insert the expansion card s int...

Страница 57: ...cribed in Section 3 1 and remove the chassis top cover 2 Remove all trays from the rear of the chassis as described in Section 3 2 3 Remove all fans and storage drives from the front of the chassis as...

Страница 58: ...JMB_E6 provide power for the system from the midplane 4 2 Headers and Connectors Onboard Fan Header Headers FAN1 FAN2 and FAN3 are not used in this system System fans are powered from the midplane TPM...

Страница 59: ...RAID Key Pin Definitions Pin Definition 1 Ground 2 3 3V Standby 3 Ground 4 PCH RAID Key M 2 Slots Two PCIe M 2 slots M 2 P1 M 2 P2 are provided on the motherboard It supports PCIe 3 0 x4 32 Gb s SSD...

Страница 60: ...A dedicated IPMI LAN GbE port is located on the I O back panel IPMI LAN is supported by the Aspeed AST2500 BMC Baseboard Management Controller This port accept a RJ45 type cable Refer to the LED Indi...

Страница 61: ...oved Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which also clears any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...

Страница 62: ...n Pins 1 2 Normal Pins 2 3 ME Recovery Watch Dog JWD1 controls the Watch Dog function Watch Dog is a monitor that can reboot the system when a software application hangs Jumping pins 1 2 will cause Wa...

Страница 63: ...functioning normally M 2 Activity LED LED1 indicates when one M 2 storage is active Dedicated IPMI LAN LEDs A dedicated IPMI LAN port is on the I O back panel The amber LED on the right of the IPMI L...

Страница 64: ...e at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB fla...

Страница 65: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 66: ...referred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash...

Страница 67: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...

Страница 68: ...ules There are several BIOS settings that are related to IPMI For general documentation and information on IPMI visit our website at http www supermicro com products nfo IPMI cfm BMC ADMIN User Passwo...

Страница 69: ...ed it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of settings in...

Страница 70: ...using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour forma...

Страница 71: ...guration Quiet Boot Use this feature to select the screen between displaying POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo...

Страница 72: ...llow the BIOS to automatically reboot the system from a Legacy boot device after an initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function Select...

Страница 73: ...mber of cores desired Enter 0 to enable all cores Enter bit0 to disable CPU Core 0 Enter bit1 to disable CPU Core 1 Note that the maximum of 24 cores are currently available in each CPU package The de...

Страница 74: ...nable the DCU Data Cache Unit streamer prefetcher will prefetch data streams from the cache memory to the DCU Data Cache Unit to speed up data accessing and processing for CPU performance enhancement...

Страница 75: ...wer consumption as energy is needed to fuel the processor frequency The higher the performance is the higher the power consump tion will be Select Max Power Efficient to maximize power saving however...

Страница 76: ...ode with No Legacy Support CPU C State Control Autonomous Core C State Select Enable to support Autonomous Core C State control which will allow the proces sor core to control its C State setting auto...

Страница 77: ...this feature to select the degrading precedence option for Ultra Path Interconnect connections Select Topology Precedent to degrade UPI features if system options are in conflict The options are Topo...

Страница 78: ...allows the user to set the threshold for the Interrupt Request IRQ signal which handles hardware interruptions The options are Disable Auto Low Medium and High Stale AtoS A to S Select Enable to remov...

Страница 79: ...rnaround time for Same Rank DDR timing setting among all memory channels and in which case the worst case value among all channels will be used Select Disable to use different values for the tRWSR DDR...

Страница 80: ...will reduce the memory capacity to half The options are Disable and Enable Memory Rank Sparing Only available when memory mirror mode is disabled Select Enable to support memory rank sparing to optim...

Страница 81: ...emory module and send the corrections to the requestor the original source When this item is set to Enable the IO hub will read and write back one cache line every 16K cycles if there is no delay caus...

Страница 82: ...iguration only Link Speed This feature configures the link speed of a PCI E this port The options are Auto Gen 1 Generation 1 2 5 GT s Gen 2 Generation 2 5 GT s and Gen 3 Generation 3 8 GT s The follo...

Страница 83: ...ration 2 5 GT s Gen 3 Generation 3 8 GT s The following information will also be displayed PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Max Maximum Payload Size Select A...

Страница 84: ...Services to all PCI E Root Port Bridges The options are Enable and Disable If Intel VT for Directed I O is enabled the following settings are available Interrupt Remapping Select Enable for Interrupt...

Страница 85: ...t do not support XHCI Extensible Host Controller Interface hand off The XHCI ownership change should be claimed by the XHCI driver The options are Enabled and Disabled Port 60 64 Emulation Select Enab...

Страница 86: ...elect RAID to configure a SATA drive specified by the user as a RAID drive The options are AHCI and RAID If this is set as RAID the following two options appears SATA sSATA RAID Boot Select Select the...

Страница 87: ...is feature enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enable and Disable Configure sSATA as Available when SATA Controller is enabled Select AHCI t...

Страница 88: ...ected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive PCIe PCI PnP Configuration The PCI Bus Driver Version is displayed PCI Devices Common Settings A...

Страница 89: ...A66 Upper PCI E 3 0 X16 for upper slot and RSC G A66 Lower PCI E 3 0 X16 for lower slot Select EFI to allow the user to boot the computer using an EFI Expansible Firmware Interface device installed o...

Страница 90: ...rt Select Enabled to enable Ipv6 PXE boot support If this feature is disabled it will not create the Ipv6 PXE boot option The options are Disabled and Enabled Ipv6 HTTP Support Select Enabled to enabl...

Страница 91: ...tribute Only for Serial Port 2 Select SOL to use COM Port 2 as a Serial_Over_LAN SOL port for console redirection The options are COM and SOL Serial Port Console Redirection COM 1 Console Redirection...

Страница 92: ...sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2...

Страница 93: ...Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use...

Страница 94: ...e options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolut...

Страница 95: ...Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Select VT100 to add color and function key support Sele...

Страница 96: ...treams providing smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to rep...

Страница 97: ...or initial system boot This early boot code is shipped with the platform and is included in the list of public keys During system boot the platform firmware uses this trusted public key to verify a di...

Страница 98: ...d and Disabled PH Platform Hierarchy Randomization for TPM Version 2 0 and above Select Enabled for Platform Hierarchy Randomization support which is used only during the platform developmental stage...

Страница 99: ...s can be changed when Smbios Event Log is enabled Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The...

Страница 100: ...ber between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window Specify how long the multiple event counter should wait before generating a new event log Enter a number between 0 t...

Страница 101: ...tatus of your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings can be chang...

Страница 102: ...to implement all IP MAC address changes at the next system boot The options are No and Yes If the item above is set to Yes the following items become available for configuration IPMI LAN Selection Us...

Страница 103: ...Chapter 6 UEFI BIOS 103 When Static is selected the user must manually enter the following values Station IP Address Subnet Mask Gateway IP Address...

Страница 104: ...haracters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Pa...

Страница 105: ...manufacturer default keys to configure the following system security settings The options are Enabled and Disabled Install Factor Default keys Select Yes to install all manufacturer defaults to confi...

Страница 106: ...s are Set New and Append Secure Boot Variable Size Key Key Sources The options are Save to File Set New and Erase Forbidden Signatures This feature allows the user to enter and configure a set of valu...

Страница 107: ...e device from which the system will boot from the top of the list to the bottom Select each entry choose a boot device When Boot Mode Select is set to Legacy or UEFI only those items are displayed Del...

Страница 108: ...ve Option Select the target boot driver to delete from the boot priority list UEFI Application Boot Priorities Boot Option 1 Choose UEFI Built in EFI Shell or Disabled Network Drive BBS Priorities Boo...

Страница 109: ...Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters t...

Страница 110: ...save any changes to the BIOS setup for future use select and press Enter Restore User Defaults To retrieve user defined settings that were saved previously select and press Enter Boot Override This f...

Страница 111: ...corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No m...

Страница 112: ...or assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Thes...

Страница 113: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 114: ...ken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...

Страница 115: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 116: ...tes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l inst...

Страница 117: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 118: ...abels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Wa...

Страница 119: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 120: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 121: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 122: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All c...

Страница 123: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 124: ...dvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques c...

Страница 125: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 126: ...ale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accord...

Страница 127: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 128: ...estornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient t...

Страница 129: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 130: ...r le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto u...

Страница 131: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 132: ...10U Rackmount WxHxD 17 2 x 17 5 x 27 6 in 437 x 445 x 701 mm System Cooling Eight 9 cm fans six 8 cm fans temperature controlled by IPMI Two CPU heatsinks One air shroud to optimize air flow Input Out...

Страница 133: ...CCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Delegated Directive EU 2015 863 and Directive 2012 19 EU Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada...

Страница 134: ...ge The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...

Страница 135: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...

Страница 136: ...if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed...

Страница 137: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 138: ...nterrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power s...

Страница 139: ...urpose you can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2...

Страница 140: ...stem remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellanous tab then the Trou...

Страница 141: ...d Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Int...

Страница 142: ...JRK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd par...

Страница 143: ...ration North Bridge IIO Configuration Intel VMD Technology CPU1 CPU2 5 Enable the VMD according to the following rules For M 2 NVMe or NVMe AIC enable the VMD according to which AOC card slot it used...

Страница 144: ...AID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure F 4 12 Se...

Страница 145: ...e device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215...

Отзывы: