Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 6019P MT 6019P MTR...
Страница 2: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may c...
Страница 3: ...necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safet...
Страница 4: ...6 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 17 Circuit Overloading 18 Reliable Ground 18 2 3 Installing the Server into a Rac...
Страница 5: ...tion 33 Memory Support 33 DIMM Module Population Sequence 33 PCI Expansion Card Installation 35 Motherboard Battery 35 3 4 Chassis Components 36 Hard Drives 36 Hard Drive Carrier Indicators 37 System...
Страница 6: ...2 Driver Installation 53 5 3 SuperDoctor 5 54 5 4 IPMI 55 Chapter 6 BIOS 6 1 Introduction 56 6 2 Main Setup 57 6 3 Advanced Setup Configurations 59 6 4 Event Logs 86 6 5 IPMI 88 6 6 Security 91 6 7 B...
Страница 7: ...Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicr...
Страница 8: ...a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoi...
Страница 9: ...to 140W Socket Type Socket P Memory Eight DIMM slots to support up to 1TB of ECC 3DS Registered DIMMs RDIMM Load Reduced DIMMs LRDIMM or 512GB of ECC RDIMM LRDIMM DDR4 2666 memory Chipset Intel C621 c...
Страница 10: ...uminated when the system is operating 6 Reset Button The reset button is used to reboot the system 7 Power Button The main power button is used to apply or remove power from the power supply to the se...
Страница 11: ...r the features included on the front of the chassis Front Chassis Features Item Feature Description 1 HDD Hot swap 3 5 SATA hard disk drive 2 Control Panel Front control panel with LEDs and buttons se...
Страница 12: ...ower Supply 6019P MT 500W single power supply p n PWS 505P 1H 6019P MTR 600W redundant power supplies p n PWS 608P 1R 2 I O Back Panel Rear I O ports see Section 4 3 3 Expansion Card Slot Slot for one...
Страница 13: ...SGPIO2 I SGPIO1 USB5 6 3 0 USB2 3 USB4 3 0 I SATA7 I SATA6 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 S SATA1 P1 DIMMA1 P1 DIMMB1 P1 DIMME1 P2 DIMMA1 P2 DIMMB1 P2 DIMME1 CPU1 SLOT6 PCI E 3 0 X8 CPU1 SLO...
Страница 14: ...USB 3 0 Type A port for USB4 JPWR1 2 8 pin Power Connector JPWR3 24 pin Power Connector JPI2C1 Power Supply I2 C Connector JSD1 JSD2 Power connector for SATA DOM JSTBY1 Wake On LAN Header IPMI_LAN Ded...
Страница 15: ...1 5 Intel C621 Chipset System Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See the System Specifications appendix for the actual sp...
Страница 16: ...Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where h...
Страница 17: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...
Страница 18: ...branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The f...
Страница 19: ...you want to place the 6019P MT MTR in the rack see Rack and Server Precautions in Section 2 2 Position the chassis rail guides at the desired location in the rack keeping the sliding rail guide facin...
Страница 20: ...ty hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip ov...
Страница 21: ...ts on either side of the chassis four total 1 First determine how far the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back...
Страница 22: ...en replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord s from the power strip or outlet...
Страница 23: ...re you install a CPU heatsink If you bought a CPU separately make sure that you use an Intel certified multi directional heatsink only When receiving a motherboard without a processor pre installed ma...
Страница 24: ...actly the same as those shown in this manual Processor The Xeon Scalable Processor Figure 3 2 Xeon Scalable Processors Overview of the Processor Socket Assembly The processor socket assembly contains...
Страница 25: ...25 Chapter 3 Maintenance and Component Installation 3 Dust Cover 4 CPU Socket Note Be sure to cover the CPU socket with the dust cover when the CPU is not installed...
Страница 26: ...MT MTR User s Manual 26 Overview of the Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a narrow processor clip and 3 the processor 1 Heatsink 2 Narrow processo...
Страница 27: ...n below 3 Align pin 1 of the CPU with pin 1 of the narrow processor clip Once they are aligned carefully insert the CPU into the processor clip by sliding notch B of the CPU into notch B of the proces...
Страница 28: ...in 1 Align CPU Pin 1 Align Notch C of the CPU and Notch C of the Processor Clip Align Notch D of the CPU and Notch D of the Processor Clip CPU Upside Down w CPU LGA Lands up CPU Heatsink Package Upsid...
Страница 29: ...triangle Also locate another set of mounting clips and a hole at the diagonal corner of the of the processor package assembly b in the drawing 4 With the under side of heatsink and the under side of t...
Страница 30: ...ket bracket the CPU socket Socket P and a back plate CPU Socket with Dust Cover On Removing the Dust Cover from the CPU Socket Remove the dust cover from the CPU socket exposing the socket pins as sho...
Страница 31: ...riangle on the CPU socket 3 Align the two holes at diagonal corners of the PHM onto the two guide posts on the socket bracket and carefully drop the PHM onto the socket 4 Use a T30 Torx bit screwdrive...
Страница 32: ...or heatsink module PHM power down as described in Section 3 1 1 Using a T30 Torx bit screwdriver turn the screws on the PHM counterclockwise to loosen them from the socket starting with screw marked 4...
Страница 33: ...ends of the module press it straight down into the slot until the module snaps into place 4 Press the release tabs to the locked positions to secure the DIMM module into the slot Repeat for other DIMM...
Страница 34: ...1 P2 DIMMD1 P2 DIMME1 Processors and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU 1 P1 DIMMA1 P1 DIMMB1 P1 DIMMD1 P1 DIMME1 CPU2 P2 DIMMA1 P2 DIMMB1 P2 DIMMD1 P2 DIMME1 Popula...
Страница 35: ...garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Warning There is a danger of explosion...
Страница 36: ...se button on the carrier 2 Swing the handle fully out 3 Grasp the handle and use it to pull the drive carrier out of its bay Mounting a Drive in a Drive Carrier 1 To add a new drive install it into th...
Страница 37: ...ermicro website at http www supermicro com products nfo files storage SBB HDDCompList pdf Removing a Drive from a Drive Carrier 1 Remove the screws that secure the hard drive to the carrier and separa...
Страница 38: ...the failed fan s cable from the connector on the motherboard 5 Gently pull upward to remove the failed fan from the housing 6 Place the new fan into the vacant space in the housing Make sure that the...
Страница 39: ...r You must power down the system before installing or removing a DVD ROM drive 1 Power down the system as described in Section 3 1 2 Next remove the top chassis cover as described in Section 3 2 3 Sec...
Страница 40: ...s to the rack then grasp the two handles on either side and pull the system straight out until it locks you will hear a click 2 Next remove the top chassis cover as described in Section 3 2 3 To remov...
Страница 41: ...until the failed unit has been replaced Replacement units can be ordered directly from Supermicro see contact information in the Preface The hot swap capability of the power supply modules allows you...
Страница 42: ...included with the power supply 24 pin Primary ATX Power JPWR3 8 pin Processor Power JPWR1 2 Main ATX Power Connector The primary power connector JPWR3 meets the ATX SSI EPS 24 pin specification You m...
Страница 43: ...ted to the power supply This connector is used to power the processor s Fan Header Pin Definitions Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control Trusted Platform Module Port 80 He...
Страница 44: ...All these SATA ports provide serial link signal connections which are faster than the connections of Parallel ATA Micro SD Card There is one Micro SD memory card slot located at JSDCARD1 on the mothe...
Страница 45: ...D LED Power LED Reset PWR UID LED Ground Ground 19 20 3 3V X Ground NMI X NIC2 Activity LED 3 3V Stby 3 3V Stby 3 3V Stby NIC1 Activity LED 3 3V Power Button Pin Definitions JF1 Pins Definition 1 Sign...
Страница 46: ...for pin definitions Power LED Pin Definitions JF1 Pins Definition 5 3 3V 6 Power Fail LED Reset Button Pin Definitions JF1 Pins Definition 3 Reset 4 Ground Reset Button The Reset Button connection is...
Страница 47: ...JF1 Pins Definition 13 3 3V Stdby 14 HDD Active Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table below for pin definitions NMI Button The non maskable interrup...
Страница 48: ...ard VGA port is located next to IPMI LAN port on the I O back panel Use this connection for VGA display Universal Serial Bus USB Ports There are two USB 2 0 ports USB0 1 on the I O back panel Back Pan...
Страница 49: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...
Страница 50: ...y and force the system to use the Manufacturing Mode which will allow you to flash the system firmware from a host server to modify system settings See the table below for jumper settings Manufacturin...
Страница 51: ...ED A rear UID LED indicator at UID_LED1 is located near the UID switch on the back panel This UID indicator provides easy identification of a system unit that may need service IPMI LAN LEDs A dedicate...
Страница 52: ...B port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper dri...
Страница 53: ...er option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your hard dr...
Страница 54: ...anagement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server...
Страница 55: ...orm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...
Страница 56: ...1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be con...
Страница 57: ...ime Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY form...
Страница 58: ...58 SuperServer 6019P MT MTR User s Manual Memory Information Total Memory This item displays the total size of memory available in the system...
Страница 59: ...ature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST...
Страница 60: ...ot and EFI Boot Install Windows 7 USB Support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA opt...
Страница 61: ...r Fail This feature allows the system to decrease system power requirements by throttling CPU frequency in the event of one power supply failing CPU Configuration Processor Configuration The following...
Страница 62: ...the main memory to the L2 cache to improve CPU performance The options are Disable and Enable Adjacent Cache Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes...
Страница 63: ...l processors In SW_ALL mode the OS Power Manager is responsible for coordinating the P state and must initiate the transition on all Logical Processors In SW_ANY mode the OS Power Manager is responsib...
Страница 64: ...options are Disable and Enable Package C State Control Package C State This feature allows the user to set the limit on the C State package register The options are C0 C1 State C2 State C6 Non Retent...
Страница 65: ...p support The options are Enable and Disable Link L1 Enable Select Enable for Link L1 support The options are Enable and Disable IO Directory Cache IODC IO Directory Cache is an 8 entry cache that sto...
Страница 66: ...s festure to enable or disable data scrambling for DDR4 memory The options are Auto Disable and Enable tCCD_L Relaxation If Enabled the tCCD_L overrides the SPD When disabled it is enforced based on m...
Страница 67: ...on all cases The x8 condition is corrected only if the system is in Lockstep Mode ADDDC Sparing Adaptive Double Device Data Correction ADDDC Sparing detects when the prede termined threshold for corre...
Страница 68: ...SLOT6 PCI E 3 0 X8 CPU SLOT4 PCI E X8 CPU SLOT5 3 0 PCI E X16 CPU SLOT2 PCI E 3 0 X8 CPU SLOT1 PCI E 3 0 X4 Link Speed Use this item to select the link speed for the PCI E port specified by the user...
Страница 69: ...s Prioritize TPH Use this feature to enable Prioritize TPH support The options are Enable and Disable Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain transac...
Страница 70: ...Enable for the Non Iscoh VT d engine to pass through DMA to enhance system performance The options are Enable and Disable Intel VMD Technology Intel VMD for Volume Management Device on CPU1 VMD Config...
Страница 71: ...able Hot Plug Capable Available when the device is detected by the system Use this feature to enable hot plug support for PCIe root ports 2A 2D The options are Disable and Enable VMD Config for PStack...
Страница 72: ...Volume Management Device Technology for this spe cific root port The options are Disable and Enable Hot Plug Capable Available when the device is detected by the system Use this feature to enable hot...
Страница 73: ...ce of the SATA devices that are supported by the Intel PCH chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH ch...
Страница 74: ...shutting down the system The options are Disabled and Enabled Port 0 Port 6 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Disable...
Страница 75: ...on the installed sSATA drive on the particular sSATA port Model number of drive and capacity Software Preserve Support Port 0 Port 2 Hot Plug Set this item to Enabled for hot plugging support which wi...
Страница 76: ...mber for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Read Request Select Auto for the system BIOS to automatically set the maximum size for a read request for a PCI E dev...
Страница 77: ...on card in this slot The options are Disabled Legacy and EFI CPU SLOT5 PCI E 3 0 X16 OPROM Use this feature to select which firmware type to be loaded for the add on card in this slot The options are...
Страница 78: ...ptions are Enabled and Disabled IPv4 PXE Support Select Enabled to enable IPv4 PXE boot support The options are Disabled and Enabled IPv4 HTTP Support Select Enabled to enable IPv4 HTTP boot support T...
Страница 79: ...3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 SOL Configuration This submenu allows the user to configure the settings of Serial Port 2 SOL Select Enabled to enable the selected...
Страница 80: ...the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for l...
Страница 81: ...led and Enabled Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPa...
Страница 82: ...Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Se...
Страница 83: ...able legacy Console Redirection after BIOS POST When set to Bootloader legacy Console Redirection is disabled before booting the OS When set to Always Enable legacy Console Redirection remains enabled...
Страница 84: ...nt computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this item to set the flow control for Consol...
Страница 85: ...and the TPM jumper on the motherboard are both set to Enabled onboard security devices will be enabled for TPM Trusted Platform Module support to enhance data integrity and network security Please re...
Страница 86: ...bled Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Ev...
Страница 87: ...plicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass between dup...
Страница 88: ...he IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing...
Страница 89: ...ddress changes at the next system boot The options are No and Yes If the item above set to Yes the following item will become available for user s configuration Configuration Address Source This featu...
Страница 90: ...PV6 support The options are Enabled and Disabled Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need...
Страница 91: ...ser Password Press Enter to create a new or change an existing User password Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a pas...
Страница 92: ...r The options are Disabled and Enabled Enroll All Factory Default Keys Select Yes to install all default secure keys set by the manufacturer The options are Yes and No Save All Secure Boot Variables T...
Страница 93: ...X Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Set New Key Select Yes to load the DBT from the manufacturer s defaults Select No to load the DBT from a file T...
Страница 94: ...ure to configure Boot Settings Boot Mode Select Use this item to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual The default setting is Dual Legacy...
Страница 95: ...acy UEFI Dual Boot Order 11 Legacy UEFI Dual Boot Order 12 Legacy UEFI Dual Boot Order 13 Legacy UEFI Dual Boot Order 14 Legacy UEFI Dual Boot Order 15 Legacy UEFI Dual Boot Order 16 Legacy UEFI Dual...
Страница 96: ...g any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Save Exit menu and press Enter Save Changes and Reset After completing the system c...
Страница 97: ...nce Save As User Defaults To set this feature select Save as User Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore Us...
Страница 98: ...occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the fo...
Страница 99: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnosti...
Страница 100: ...100 SuperServer 6019P MT MTR User s Manual...
Страница 101: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Th...
Страница 102: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 103: ...ken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...
Страница 104: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 105: ...tes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l inst...
Страница 106: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 107: ...abels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Wa...
Страница 108: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 109: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 110: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 111: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All c...
Страница 112: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 113: ...dvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques c...
Страница 114: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 115: ...ale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accord...
Страница 116: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 117: ...estornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient t...
Страница 118: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 119: ...r le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto u...
Страница 120: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 121: ...drives PCI Expansion Slots supported One PCI Express 3 0 x8 slot supported by CPU1 Motherboard X11DPL i ATX form factor 12 07 x 10 15 in 307 x 258 mm Chassis SC813MF2TS 505CBP R608CBP 1U Rackmount 17...
Страница 122: ...4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices...